manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CONCEPT 2000
  6. •
  7. Control Unit
  8. •
  9. CONCEPT 2000 IR-Link CP 70A User manual

CONCEPT 2000 IR-Link CP 70A User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5.29
IR-LinktypeCP70A
IR-LinktypeCP70AFunctionalprincipleofIR-LinktypCP70A
ControloptionswithIR-Link
Terminals(lowcurrent)
TerminalB+Plus24VDC
C-Minus(-)
DDPreamplifierinput1
EEPinput2
FFPinput3
GGPinput4
HHPinput5
IIPinput6
KKPinput7
LLPinput8
TerminalSymbolInput
Terminal
Terminal
Terminalreamplifier
Terminalreamplifier
Terminalreamplifier
Terminalreamplifier
Terminalreamplifier
Terminalreamplifier
Terminalreamplifier
EAN-No.5703513006303
TechnicaldataIR-LinktypeCP70A:
Lowcurrent
Voltage24VDC(18-28V)
Currentat18VDCmax.30mA
Powerconsumptionat18VDCmax.0,5VA
Powerconsumptionpr.preamplifier0,6VA
Impulsetimemin.50ms
Terminalsformax.2,5mmØ
Cablelengthmax.100m
MechanicaldataforCP70A
Temperaturerange-5º......+35ºC
Installationforbuilding-in
Isolation4KV>8mm
InsulationDIN40050
DINrailsymmetricDIN46277
Dimensions(HxWxD)85x70x72
WeightCP70A100g
ConnectiondiagramIR-LinktypeCP70A
Productdescription
RemotecontrolmoduleIR-LinktypeCP70Ais
especiallydevelopedforremotecontrolof
CONCEPT2000lightcontrolsystemwith38KHz
infraredremotecontrolstypeCP76(8channels)
andtypeCP79(32channels).
IR-linktypeCP70cantransmit8channelson
thedatabusandwithpossibilitiesofconnection
ofupto8IR-preamplifiers.
Themoduletransmitsatimpactviainfrared
preamplifieracommandoverthedatabus.
Commandsarereceivedbytherespectiverelay
anddimmermodules,whichthenreactonthe
commandasrequired.Theaddressingand
programmingaredonebymeansofIR-remote
con trolandprogrammingkeysCONKEYtypeCP
79.
Thechannelrangetobeused(1-8,9-16,17-24
etc.seetableoffunctionsontheback)is
programmedintothemodule.Onlyonechannel
rangeatatimecanbeactivepr.module.
Upto4pcs.CP70canbeconnectedonthebus
i.e.32channelscanbeestablishedforIRremote
control.Powersupplyisviathe3-pinplug
provided,whichisconnectedtothemodules.Via
thisplugplus(24VDC),minusanddataare
connected.
Installationguide.
MountthemoduleontheDINrailandconnect
theplugbetweenthemodules.Viathisplug+/-
and"datacord"areconnected.
Connectlowcurrenttothemodule,andcheck
connectionbeforevoltageissuppliedforthe
module.CP70Amusthaveexternalpower
supplyfromtypeCP11(18-28VDC).
Lightscene1
MEAL
Lightscene2
GUESTS
Lightscene3
TELEVISION
Lightscene4
CLEANING
COFFEE
TABLE
WALLCEI-
LING
Lightrequirements
Toggleswitches
Helprelays
(Curtaincontrol)
Lightdimmers
10.08.97
TRIAC-dimmer
Leadingedge
Transistordimmer
Trailingedge
0-10V
Ballastcontroller
Lowcurrentcontrol
Relaymodule
typeCP24
Relaymodule
typeCP24
Dimmermodule
typeCP31LR
Dimmermodule
typeCP31CR
Dimmermodule
typeCP31BC
+F
Forforstærkerindgange
Moduleno.
+_D
+_D
+_
CP70A
BC D EFGHIKL
24V12345678
Plus24V
Minus(-)
Data
Plus24V
Minus(-)
Data
1
2
3
4
5
+-F
LD
1LD
2LD
3LD
4LD
5
S1
S2
S3
S4
S5
IR-preamplifier
FUGA50x77mm
typeCP72HTouchbuttonpanel
withbuilt-in
IR-preamplifier
-typeCP2502
-typeCP2507
ON/OFF
ON/OFF+
REGULATION
DATADATA
8channels
CP70A
3
Infrared-preamplifier
receives38KHzsignals
fromremotecontrolsand
transmitsthemoncordfor
thedecoderIR-Linktype
CP70A.
IR-LinkCP70A
receivessignals
fromIR-
preamplifier,
decodesthemand
transmitsthemon
thedatabusto
activemodulestype
Infraredremotecontrol
transmits38KHzsignals
(8/32channels)to
infraredpreamplifier(s).
DINING
TABLE
5.30
IR-LinktypeCP70A
Pressbutton1-32channels-Link-no.1-4CP-BusBuscommandBuscommand
HS-no.1T-no.2T-no.3T-no.4channelpressletgo
191725
2101826
3111927
4122028
5132129
6142230
7152331
8162432
(1)*(1)*(1)*1**StartStop
(2)*(2)*(2)*2**StartStop
(3)*(3)*(3)*3**StartStop
(4)*(4)*(4)*4**StartStop
(5)*(5)*(5)*5**StartStop
(6)*(6)*(6)*6**StartStop
(7)*(7)*(7)*7**StartStop
(8)*(8)*(8)*8**StartStop
7654321
87654321
S1
S2
7654321
87654321
S1
S2
7654321
87654321
S1
S2
7654321
87654321
S1
S2
Applicationexample:Applicationof4pcs.IR-LinktypeCP70Ain4differentrooms(4x8channels).
Each8-channelIRremotecontroltypeCP76canonlybeusedintheroomwhereitbelongs,32-kanal
IR-remotecontroltypeCP79canbeusedinallrooms.ThediagramsbelowshowprogrammingofIR-
Linkno.1-4(NOTE!Moduleno.N7-N10isaccidentallychosen,dependsonpositioninthesystem)and
remotecontrolmenuLIGHTforcontrolwithCP79.REMEMBER!Max.4pcs.IR-Linkpr.datastring.
ProgrammingofIR-LinktypeCP70:
Atprogrammingthefollowingmustbestated:
moduleno.(1-200,dependsofposition),Link-no.(1-
4,max.4pcs.),remotecontroltype(HSType:1-4)
andremotecontrolno.(HSno.1-52=channel
range).
TType:1-8channelIRremotecontroltypeCP76
-32channelremotecontroltypeCP79
TType:2-Nouse
TType:3-Nouse
TType:4-Nouse
Tno:1-Channelrange1-8
Tno:2-Channelrange9-16
Tno:3-Channelrange17-24
Tno.4-Channelrange25-32
to
Tno.64-Channelrange505-512
NOTE!IR-Link-no.1-4onlytransmitchannel1-8on
thedatabus,eventhoughyoue.g.havechosen
channelrange/HSno.17.IRremotecontrolstype
CP76with8channelscanbecodedfor64channel
ranges.RemotecontroltypeCP79onlytransmits
fromchannel1-32andcannotbecodedtoother
channelranges.ThemoduleCP70Aispreprogram
-medwithmoduleno.4,Link-no.1(seeabove).T:CP70AN7Link-No.1
TType:1Tno:1
T:CP70AN4Link-No.1
TType:1Tno:1
910111213141516
ChannelNo:91718192021222324
ChannelNo:172526272829303132
ChannelNo:25
T:CP70AN8Link-no.2
TType:1Tno:2T:CP70AN9Link-No.3
TType:1Tno:3T:CP70AN10Link-No.4
TType:1Tno:4
8channels
CP70A
ROOM1
3
8channels
CP70A
ROOM2
3
8channels
CP70A
ROOM3
3
8channels
CP70A
ROOM4
3
CP76forroom1
codedtochannel1-8CP76forroom2
codedtochannel9-16CP76forroom3
codedtochannel17-24CP76forroom3
codedtochannel25-32
CP79-RemotecontrolRemotecontrolmenuforlightcontrolwith1-32channelsCP79-RemotecontrolCP79-RemotecontrolCP79-Remotecontrol
*IRremotecontroltypeCP76canbecodedtodifferentchannelranges(HSno.).
**REMEMBER!Link-no.1-4mustbeprogrammed(max.4pcs.CP70Apr.datastring).
AtprogrammingofactivemodulesIR-Link-no.1-4andchannel1-8mustbestated.
FRIDAY11/212:02
TypeCP79
Infraredremotecontrol32channels+
programmingkey
EAN-NO.5703513007119
1
3
2
4
6
8
5
7
Tobeabletochooseanotherchannel
rangetheremotecontrolcabinetmustbe
openedbyloosening4screwsonthe
back(2screwsunderbatterycover).
TypeCP76
Infraredremotecontrol8channels
EAN-NO.5703513006723
CP76ismanufacturecodedtochannel1-8.
7654321
87654321
S1
S2Codechange-over
switchontheprint
inCP76
12345678
ChannelNo:1
Withthecentrebuttonthechosen
channelnumberistransmitted
IRremotecontrolsforremotecontrol
withIR-LinktypeCP70A:
10.08.97