manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CONQUEST
  6. •
  7. Scanner
  8. •
  9. CONQUEST 100 User manual

CONQUEST 100 User manual

Popular Scanner manuals by other brands

Radio Shack PRO-433 quick start guide

Radio Shack

Radio Shack PRO-433 quick start guide

Atid AT911N series user guide

Atid

Atid AT911N series user guide

Siemens RUGGEDCOM WiN5100 Faq

Siemens

Siemens RUGGEDCOM WiN5100 Faq

Canon CanoScan LiDE 20 Specifications

Canon

Canon CanoScan LiDE 20 Specifications

Epson 4180 - Perfection Photo Product support bulletin

Epson

Epson 4180 - Perfection Photo Product support bulletin

Radio Shack PRO-72 owner's manual

Radio Shack

Radio Shack PRO-72 owner's manual

Lanier 5622 Operator's guide

Lanier

Lanier 5622 Operator's guide

Faro Freestyle 2 user manual

Faro

Faro Freestyle 2 user manual

Kramer VS-16N user manual

Kramer

Kramer VS-16N user manual

Z/I Imaging PhotoScan 2001 instructions

Z/I Imaging

Z/I Imaging PhotoScan 2001 instructions

Renkforce DS100-5M operating instructions

Renkforce

Renkforce DS100-5M operating instructions

Canon imageFORMULA CR-120N user manual

Canon

Canon imageFORMULA CR-120N user manual

Fujitsu FI-4860C2 Specifications

Fujitsu

Fujitsu FI-4860C2 Specifications

HPc9861a 4400c Setup and support guide

HPc9861a

HPc9861a 4400c Setup and support guide

Kodak i5800 Scanner Brochure & specs

Kodak

Kodak i5800 Scanner Brochure & specs

Kodak i7300 user guide

Kodak

Kodak i7300 user guide

Revopoint POP user manual

Revopoint

Revopoint POP user manual

Fujitsu fi-4860C installation guide

Fujitsu

Fujitsu fi-4860C installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Star key
Add a ag
Enter key
Start and Stop
data collection
Battery Charger/AC Adapter
Display Unit
Cable
Note: New batteries are shipped
in an inoperative “Transport”
mode for safety. Batteries must be
charged before they will function.
Battery can be charged while you
use the system by plugging in the AC
adapter.
Allow the battery to charge for
3-4 hours.
Navigaon Buons
Power Button
Turn on/off the system
Touch sensitive screen
Touch the icons on the screen
Function keys
Use the numbered 1-8
buttons that correspond
to the function above it
Quick Start
USB Port
Transfer images
to PC with a
memory stick
Star key
Add a ag
Camera
Save an image of the
screen. This image
can be transferred to
a USB memory stick
or embedded
into a simple report
and sent wirelessly to
an e-mail
address.
Sensor Head
Li-Ion Battery
Attach the male end of the cable to the
connector on the back of the
Display Unit.
Connect the female end of the yellow
cable to the Sensor Head.
Insert Li-Ion battery into the battery
compartment on the Display Unit
www.sensoft.ca
Assembly
Features
AC Power
System will run
on AC Power
Depth scale Horizontal Position
1. Place the Sensor Head on the surface and press Start key on the
Display Unit or Enter key on the Sensor Head.
2. Move the Sensor Head forward.
3. Data scrolls on the screen from right to left.
4. PCD (Power Cable Detector) data is displayed as a red line
under the cross-section image.
5. DynaQ line is an indicator of data quality.
6. FINISH - Press Stop on the screen or the Enter key
on the Sensor Head.
ADJUST DISPLAY PARAMETERS - Use the menu options along the
bottom of the screen to change: Color, Filter, Gain, and Zoom.
To pinpoint the location
of an embedded object
move the Sensor Head
backwards.
A red vertical line
(corresponding to the
arrow at the center of
the Sensor Head) will
appear on the screen
marking the position of
the Sensor Head.
Line Scan Displays Cross-Sectional GPR Data - Get a quick idea of what`s in the concrete, locate rebar and current-carrying cables.
Start Up
Scan
Using tape, secure the plastic grid sheet
at the survey location.
Set your grid
parameters: grid
number, size and
resolution. Then
press Start.
Align the Sensor Head
so it is centered on Line
1 and the middle of the
wheels line up with the
start line on the grid.
1. Press Start on the Display Unit or Enter key on the Sensor Head.
The sensor will beep once to indicate the start of collection.
2. Move the Sensor Head at a steady pace in the direction of the arrows shown on the grid. Collection stops
automatically at the end of a line.
3. The GPR line appears on the left side of the screen. Underneath it is the Power Cable Detector (PCD) image in red,
indicating the possible presence of a current-carrying wire.
4. Collected line turns red on the grid image on the right side of the screen. The next line to collect is shown in white.
5. Normal resolution lines are collected every 4 inches (10 cm). For a high resolution grid, collect lines every 2 inches
(5cm); these lines are denoted with an H.
6. Continue until all the numeric (X) and alpha (Y) lines in the grid are collected.
7. Press Slice View on the screen, to process the grid data and create the depth slices.
Viewing Results
Depth slice images of the scanned area appear on the
right side of the screen. Slice up and down through the
depth slices by pressing the Depth –/+ buttons. This
increments 1 inch (25mm) at a time.
The left side of the screen displays one of the GPR grid
lines. Use the 4-way Navigation buttons to change the
alpha or numeric GPR line displayed.
2015-00041-03
Grid Scan
Scan
Displays Depth Slices - Better visualize embedded objects in an area. High resolution grids provide the best image quality.
Pinpoint Targets
To view the
PCD plan map
image, press
the PCD
button.