ConServ CMV 400 User manual

Read the instructions carefully and keep for future reference
OWNER’S MANUAL
Commercial/Medical Refrigerator
MODEL: CMV 1300 GMODEL: CMV 400
Scan the above QR code to download the “Tuya Smart” app to operate the WiFi function

installing incorrectly
using solvents
Mishandling e.g. breakage of shelves
ConServ Appliances
10216 Georgibelle Drive, Suite 900D
Houston, Texas 77043-5249
(Conserv
Conserv
Conserv
Conserv
1-800-776-3538
CMV 400 CMV 1300 G
You can register your Warranty by any of
the following methods:
-
1. Open Smart Phone
2. Open Photo
3. Scan QR Code
1. Scan the QR Code
2. Online at: ApplianceDesk.com/Warranty
QR Code QR Code

State of California Proposition 65 Warnings:
WARNING:This product contains one or more chemicals known to the State of California to cause cancer.
WARNING:This product contains one or more chemicals known to the State of California to cause birth defects or
other reproductive harm.
Do not puncture or damage refrigerant tubing.
Safe Disposal
Before discarding the refrigerator, remove doors in order to prevent risk of child entrapment.
Leave shelves in place.
U
Use a dedicated power outlet and a three prong power socket, that is properly
grounded.
Do not use the power cord or plug if it is damaged.
When removing the power plug, do not pull on the cord. Grasp the plug firmly and pull
it out from the socket.
Unplug the unit first when doing maintenance or repair.
Repairs must be done only by a qualified technician.
Do not use extension cords or ungrounded two prong adapters.
This appliance is not intended for use by children or persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not
play with the appliance.
Customer Service.
Do not put acid or flammable or volatile materials inside the appliance.
1
Safety
Please always follow the safety precautions listed below:
Secure the cord behind the unit to prevent a tripping hazard.
Do not connect or disconnect plug with wet hands.
Keep ventilation openings free of obstructions.
Dispose off this appliance in accordance with local regulations.

Placement
This unit is designed to be free standing or built-in and used indoors.
The unit should be placed in a ventilated and dry environment.
Do not put the unit in direct sunlight, and keep it as far as possible from heat sources.
Do not put the unit in a cold or moist area.
The unit should be placed on flat and stable ground. Keep the unit level by adjusting the
2 front leg levelers.
The refrigerator can be placed with at least a space of 2" (5 cm) around the top, sides
and back of the unit to allow proper ventilation.
2
Installation
Ensure the vent in the front of the refrigerator is not covered or blocked.
Installation must be done in accordance with local regulations.
Installation under counter for CMV 400
CMV 400 can be installed under a counter keeping minimum space required as shown below.

Before Use
Before initially plugging in the refrigerator, keep the unit standing upright and stable for
at least 2 hours.
The refrigerator should be on for 4 to 6 hours and adequately cold, before putting items in it.
It is recommended that you clean the interior of the unit before placing items inside.
This appliance is designed for the storage of medicine and other medical products.
Do not store beverages or perishable food in this unit.
Do not open the door more often than necessary.
Do not overfill the unit. Allow space between stored items.

3
Control Panel
Operating Instructions
There are 4 buttons on the control panel:
SET
Press the SET button for 1 second to see the display on the control panel.
Press the SET button for 5 seconds to set or change the temperature or lighting on
the control panel.
HI LO
Press the HI LO button to view or select the highest and lowest temperature.
Power/Temp Up
Press the Power and Arrow Up button to turn the power on and off and also to
increase the temperature.
Light/Temp Down
Press the Light and Arrow Down button to turn the lighting on and off and also to
decrease the temperature.
The front top of the Refrigerator has a Lock, Control Panel, USB connection and
Reset Switch.
Operation
When the Refrigerator is first plugged in, the compressor will start to run, which will show as
an indicator light on the Control Panel and the temperature inside the unit will also be displayed.
To turn the refrigerator On: Press the Power button.
To set the temperature: Press the SET button and the Arrow Up or Arrow Down button
at the same time. Once the desired temperature has been selected, press the SET
button to save the temperature setting.
Press the Light button to turn on or off the lighting in the refrigerator.
Press the HI LO button to see the highest and lowest temperature in the display.
To start or stop Defrost, press both the SET and HI LO button at the same time for 3 seconds.

S1 Refrigeration: Flashing icon indicates refrigeration is delayed.
S2 Light: Shows whether light is on or off.
S3 Door open alarm: Indicates the door is open.
S4 Fan: Shows when the Evaporator Fan is working.
S5 Defrost: Shows if the refrigerator is being defrosted.
S6 Clock: Time settings.
S7 Alarm: This icon flashes while the temperature is being set.
S8 WiFi: indicates one of four WiFi status:
Off: WiFi module is not connected.
Quick flash: WiFi module is waiting for network distribution.
Slow flash: WiFi module is connected to the router, but not connected to the network.
On: the WiFi module is connected to the router and the network.
Setting the Time
Press the Up and Down buttons at the same time for 1 second –
the display will show “YR”
Press the Up or Down buttons to program the desired year.
Repeat this process to program:
-Month “MH”
-Day “dy”
- Hour “Hr”
-Minute “Mn”
Once you have programed the time, press the SET for 3 seconds to save.
There are 8 icons on the display screen:
4

Alarm Codes
turn On/Off the light.
control panel
control panel.control panel
control panel
control panel
control panel
5

Clean inside, behind and around the refrigerator regularly, using water and mild
detergent, and a damp cloth (not wet).
Clean the door gasket regularly to ensure that the door closes and seals properly.
Never use boiling water, harsh cleaning chemicals or abrasive materials.
Extended Absence
Leave the door open and place the unit in a well ventilated area to avoid build up of odor.
If the unit will be switched off for a long time, remove all items, turn off the appliance
and clean the unit throughly.
Defrost
The surface of the evaporator will ice up over time when the refrigerator is in use. This is a
normal process. The refrigerator must be defrosted and cleaned on a regular basis to avoid
unnecessary energy consumption and inefficient operation.
Maintanance
Simply
The following phenomenon is normal
6
Always remove all items and unplug the unit before cleaning.
Dry all surfaces thoroughly.
After defrosting, clean the appliance and allow it to dry.
Remove all items and unplug the appliance.
Plug in the refrigerator and wait 4 to 6 hours for the unit to be at the correct temperature
before putting your items back.
We will add the following bullet item at the end of the Cleaning section: The Condenser is
located at the back or bottom of the unit. It should be cleaned every 3 months using a
vacuum hose.

7
Troubleshooting
This is normal.
No action needed.
This is normal.
No action needed.

CMV 400
Commercial Ref.
3.8 cu.ft.
120V / 60Hz
R600a
No Frost
82 / 95
35 x 24 x 21.3
Weight (Net/Gross) lbs
Certification UL & ETL
Rated Voltage / Frequency
Capacity
Category
Model No.
Package Dimensions (H*W*D) inches
Product Dimensions (H*W*D) inches
P
71 x 29.9 x 29
Refrigerant
Type of Defrost
Temperature Range
Electronic
Thermostat
CMV 1300 G
Commercial Ref.
12.7 cu.ft.
120V / 60Hz
R600a
No Frost
157 / 177
65 x 23.4 x 28
Weight (Net/Gross) lbs
Certification UL & ETL
Rated Voltage / Frequency
Capacity
Category
Model No.
Package Dimensions (H*W*D) inches
Product Dimensions (H*W*D) inches
P
71 x 29.9 x 29
Refrigerant
Type of Defrost
Temperature Range
Electronic
Thermostat
35 F to 46 F
O O
8
35 F to 46 F
O O

S6 Clock: Time settings.
S3 Door open alarm: Indicates the door is open.
8
This manual suits for next models
1
Table of contents
Other ConServ Refrigerator manuals

ConServ
ConServ MDRF 1010ESE User manual

ConServ
ConServ RF 1012 DC S User manual

ConServ
ConServ CRF 450 B User manual

ConServ
ConServ MDFR 280WE User manual

ConServ
ConServ RF 132 R User manual

ConServ
ConServ TMRI 180 S User manual

ConServ
ConServ FR1350SS-N User manual

ConServ
ConServ FR1700EL User manual

ConServ
ConServ CT 375 User manual

ConServ
ConServ CREF 26 SS User manual