SH-8008F Setup Guide
Network Cables
Cablesmeetingthefollowingspecificationsshould beused:
- 10BASE-T : Equal to greater than Category 3 UTP, STP cable 100m or less
- 100BASE-TX : Equalto greaterthan Category 5 UTP, STP cable 100m or less
- There arestraight/cross UTP and STP cables. Auto MDI/MDI-XfeatureallowsconnectionofyourSwitchingHUB
unit to apersonal computer (LAN adapter) or another HUBunitand a bridgesusing eithera straight or cross cable.
Inspection
Inspect theproductperiodically as follows to use it safely.
Neither dustnoralien substance is attached to the ventilation slits.
FCC PART15 Class A Notice
FCCWARNING
Changes ormodifications not expressly approvedbythe partyresponsibleforcompliancecould void the user's
authority tooperate theequipment.
NOTE:
This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15ofthe
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and,ifnot
installed and used in accordance with the instruction manual, may causeharmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which casetheuser will be
required to correctthe interferenceat his own expense.
EN55032 Class ANotice
Warning:Operationofthis equipmentin a residentialenvironment could causeradio interference.
Thecaution when youregister ULforyoursystem with this product
- Use POA201-10-2of the optionalproducts.
Specifications
Specifications
–
10Mbps/100Mbps (auto-negotiation)
All ports: Full/Half duplex (auto-negotiation)
Full Duplex : IEEE802.3x compliant flow control
Half Duplex : Back pressure
Number of effective ports
8,130pps (at 10Mbps) / 148,800pps (at 100Mbps)
8,130pps (at 10Mbps) / 148,800pps (at 100Mbps)
POWER (Green), LINK/ACT (Greed), SPEED 10/100M (Orange)
Reverse polarity protection
Power supply connector equipped with FG pin
When inputting 12V : 0.12A,When inputting 24V : 0.06A
40(W) x 60(D) x 90(H) (exclusive of protrusions)
Module installation method
Attachment of a 35mm DIN rail.
*1 This product can operate with a single powersupply. Also, you can add redundancy to the power supply by adding
a second powe r supply input.
Installation Environment Requirements
10 -90%RH (No condensation)
Line-Noise
resistance
AC line/2kV, Signal line/1kV (JIS C61000-4-4Level 3, EN61000-4-4Level 3)
Static electricity
resistance
Contact discharge/4kV (JIS C61000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (JIS C61000-4-2Level 3, EN61000-4-2Level 3)
Vibration
resistance
Sweep
resistance
10 -57Hz/semi-amplitude 0.15mm,57 - 150Hz/2.0G
40minutes each in X, Y, and Z directions
(JIS C60068-2-6-compliant, IEC60068-2-6-compliant)
15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C60068-2-27-compliant, IEC60068-2-27-compliant)
Class D grounding (previous class 3 grounding)
VCCI Class A, FCC Class A, UL,
CE Marking (EMC Directive Class A, RoHS Directive)
Physical Dimensions
Handling Precautions
- Do not use the productwhere itis exposedto flammableor corrosivegas. Doingso may result inan explosion,fire, electricshock,orfailure.
- Do not allow this device to come into co ntact with foreign substances (metal particles, flammable substances, liquids, etc.) Thiscancausefireorelectricalshock.
- Do not place this device in anunstable locationor use incompletemountings.This mayc ause the device to fall.
- Besure to connectthe product to thestipulated powersupply voltage.Connectingto adifferentvoltage mightcause a fireorelectricalshock.
- Thisproduct is not intended for use in aerospace, space, nuclearpower, medical equipment, or other applications that require a very high levelof reliability. Do not use
the product in such applications.
- If using this product in applications wheres afety is criticalsuch as in railways, automotive, or disaster preventionor securitysystems,pleasecontactyour retailer.
- The link speed value(e.g., 100Mbps) of the transmissionrateused intheManual (thisdocument) is the theoretical maximumvalueof thewired LANstandardanddo
not indicatethe actual data transmission speed.
- The frameloss could occurdependingon theconnectiondestinationor installed environment.
- Thisproductcontains precisionelectronic elements and must notbe used in locations subject to physicalshock orstrong vibration. Otherwise,theboard may
malfunction,overheat,orcausea failure.
- Avoid transportingthis productsstatetoshockor vibration thatexceeds range ofspecification.
- Do not useorstorethe equipmentina hot orcold place,or in aplacethatis subject to severe temperaturechanges. They may causethe malfunction, heat generation,
fault,ordamage.
- Do not use or storethe equipment in aplace subject to directsunlightornear aheatingdevice,such as astove. Anddo notuseorstoretheproduct near equipment
generating astrongmagnetic fieldor radio waves. They may causethe malfunction, heatgeneration,fault, ordamage.
- Do not useorstorethisproduct inthepresenceofchemicals.
- Use theproduct in thespecified operatingcondition(temperature, humidity, vibration and shock)
- Please adjustthe aircurrent to preventthe rejectheatfrom theproductstayingaround the product.
- Do not use this productinextremely humid or dustylocations. It is extremelydangerous to use this productwith its interiorpenetrated by water or any other fluid or
conductivedust. If this product mustbe used in suchanenvironment, install it onadust-proofcontrol panel, forexample.
- If you noticing abnormalodor oroverheat,please unplugthe powercord immediately.
- When you find faults or abnormalities (badsmell orexcessive heat), pullthepowercord off, thencontact theshop you boughttheproductor your retailer.
- When usingonepower supplyinput,do not touchthe unconnected powersupply connector. Doingso mayresult inelectric shockor failure.
- Whenplacingimportanceon line-noise resistance, use shielded cables to connect to periphery devices.
- Theproductcould be veryhot in the operation. Pleasedo nottouchby handsor body. It maycauseburns.
- To avoid electric shock, please do not touch the system with a wet hand.
- Do not openthe unit casing. CONTEC willdisclaimany responsibility forequipmentwhosecasing hasbeenopened.
- Do not modifytheproduct. CONTEC will bearno responsibility for anyproblems, etc., resultingfrommodifyingthis product.
- Tocleanthis product, gently wipe it with asoftclothsoaked with waterora neutraldetergent. Do not usebenzene, a thinner, orothervolatile solvents as theycancause
thecoatingtodiscolororpeeloff.
- Whenconnecting cables, first check theshapes ofconnectors (such as LANconnectors), andthen insertthemin thecorrectorientation. Afterthey areconnected,do not
put too much load on the connected part. Doingso mayresult in poorcontactor damage to this product and theconnectedpart.
- Do not touch terminals oftheproduct with yourhands in operation. Otherwise, this product maymalfunction,overheat, or cause a failure.
- The specificationof this product is subjecttochangewithout noticeforenhancement andquality improvement. Even when usingthis productcontinuously, be sureto
read themanualofCONTEC’swebsite and understandthecontents.
- If you moveortransfer theproduct, makesureto attach theSetupGuide(this document).
- To use theproduct inplaces affectedbyovercurrent orovervoltage(lightningsurge, etc.),select appropriate surgeprotectiondevice(SPD) for allentrypaths (power line,
LAN, ground, etc.). For selection/introd uction/installation of SPD, please consult a specialist.
- Regardless of theforegoingstatements,CONTEC is not liable for any damages whatsoever (including damages for loss ofbusiness profits)arisingoutof theuseor
inability to use this CONTEC productorthe informationcontained herein.
- Whendisposingthis product,pleasecomplywith themunicipalregulations and ordinances.
LTD.
-9-31, Himesato, Nishiyodogawa-ku, Osaka555-0025,Japan
Japanese http://www.contec.co.jp/ English http://www.contec.com/
Chinese
http://www.contec.com.cn/
No part of this documentmay becopied or reproducedin anyform byanymeanswithout priorwrittenconsentof CONTEC CO., LTD.
12-24VDC
14
18
φ4
60 5
90 40
18
Open
[mm]