Cool Air CPL450 User manual

(English) (CPL)
OWNER’S MANUAL
CPL Evaporative Cooler
®
ILL1456-A

1CPL Evaporative Cooler
®
Introduction
Wall Control Functions
Drain Valve & Bleed System
Maintenance
Troubleshooting
8
7
3
2
10
2
SEELEY INTERNATIONAL – OWNER’S MANUAL
INTRODUCTION
Congratulations on choosing a
new Coolair cooler for your
home.
Your cooler is built from the
highest quality materials and
engineered to provide many
years of economical, trouble free
cooling.
Please take a few minutes to
read these instructions so you
have a full understanding of how
to operate your cooler. Your
installer should demonstrate the
features and procedures set out
in these instructions. The
installer should also provide you
with a Model and Serial number,
which can be filled out on the
last page.
Keep these instructions in a
safe place for future reference.
This appliance is not intended for
use by persons (including
children) with reduced physical,
sensory or mental capabilities, or
lack of experience and
knowledge, unless they have
been given supervision or
instruction concerning use of the
appliance by a person
responsible for their safety.
Children should be supervised to
ensure that they do not play with
the appliance.
EFFECTIVE COOLING
To provide efficient cooling or
ventilation the building must have
sufficient exhaust openings to
outdoors in the form of doors,
windows or other vents. To assist air
circulation, open windows or doors
that are furthest from the outlet vent
in each room. In every room that has
an outlet vent, provide an exhaust
opening about 2 or 2.5 times the vent
size of the room. Where the design
of the building prevents adequate
exhaust, consideration should be
given to the provision of mechanical
extraction such as an exhaust fan.
Total minimum openings for the
whole building are demonstrated by
the following table:
Please note that an average size door is 1.5m2
Cooler Model Exhaust Opening
2.0m2
CPL450
CPL600
CPL700
CPL850
CPL1000
CPL1100
2.5m2
2.5m2
3.0m2
4.0m2
4.0m2

1CPL Evaporative Cooler
®
Introduction
Wall Control Functions
Drain Valve & Bleed System
Maintenance
Troubleshooting
8
7
3
2
10
2
SEELEY INTERNATIONAL – OWNER’S MANUAL
INTRODUCTION
Congratulations on choosing a
new Coolair cooler for your
home.
Your cooler is built from the
highest quality materials and
engineered to provide many
years of economical, trouble free
cooling.
Please take a few minutes to
read these instructions so you
have a full understanding of how
to operate your cooler. Your
installer should demonstrate the
features and procedures set out
in these instructions. The
installer should also provide you
with a Model and Serial number,
which can be filled out on the
last page.
Keep these instructions in a
safe place for future reference.
This appliance is not intended for
use by persons (including
children) with reduced physical,
sensory or mental capabilities, or
lack of experience and
knowledge, unless they have
been given supervision or
instruction concerning use of the
appliance by a person
responsible for their safety.
Children should be supervised to
ensure that they do not play with
the appliance.
EFFECTIVE COOLING
To provide efficient cooling or
ventilation the building must have
sufficient exhaust openings to
outdoors in the form of doors,
windows or other vents. To assist air
circulation, open windows or doors
that are furthest from the outlet vent
in each room. In every room that has
an outlet vent, provide an exhaust
opening about 2 or 2.5 times the vent
size of the room. Where the design
of the building prevents adequate
exhaust, consideration should be
given to the provision of mechanical
extraction such as an exhaust fan.
Total minimum openings for the
whole building are demonstrated by
the following table:
Please note that an average size door is 1.5m2
Cooler Model Exhaust Opening
2.0m2
CPL450
CPL600
CPL700
CPL850
CPL1000
CPL1100
2.5m2
2.5m2
3.0m2
4.0m2
4.0m2

3CPL Evaporative Cooler
®
STARTING YOUR COOLER
The ON/OFF button turns the air cooler
on and off.
There are two modes of operation to
choose from, Automatic mode or
Manual mode. When the air cooler is
turned on, it will start in the mode of
operation it was in when last turned off.
If your air cooler has not been operated
for a while, then when you start it, “Pre
Cool Cycle” may sometimes flash on
the display as shown. This indicates
that the water pump will operate to
saturate the cooling pads for a few
minutes before the fan is turned on.
This is to ensure that when the fan
starts, only cool air enters the building.
ILL1085-A
4SEELEY INTERNATIONAL – OWNER’S MANUAL
AUTOMATIC MODE
MANUAL MODE
The AUTO button is used to select
Automatic mode or Manual mode.
When “Auto” is displayed the cooler is
under Automatic control and will
operate according to the temperature
sensed at the wall control.
When the air cooler is turned on, it will
read the temperature and set the
cooler operation accordingly. If the
temperature increases at the wall
control, then the fan speed will
increase. As the temperature
decreases the fan speed will decrease
until the cooler turns off.
Press or to overide the
automatic cooling level setting and
adjust your room temperature.
To switch to Manual mode, press
AUTO until “Man” appears in the
display. In Manual mode the cooling
level can be manually adjusted.
In Manual mode, press to
choose between circulating cool air or
uncooled air. When “Cool” is
displayed, fresh cool air will circulate
into the building. When “Vent” is
displayed as shown, fresh uncooled
air will circulate through the building.
Press to increase the fan speed
and circulate more air. Press to
decrease the fan speed and circulate
less air. Press once to change the
speed by one increment. Hold the
button down to change the speed
more quickly.
COOL
AUTOMATIC MODE DISPLAY
MANUAL MODE DISPLAY

3CPL Evaporative Cooler
®
STARTING YOUR COOLER
The ON/OFF button turns the air cooler
on and off.
There are two modes of operation to
choose from, Automatic mode or
Manual mode. When the air cooler is
turned on, it will start in the mode of
operation it was in when last turned off.
If your air cooler has not been operated
for a while, then when you start it, “Pre
Cool Cycle” may sometimes flash on
the display as shown. This indicates
that the water pump will operate to
saturate the cooling pads for a few
minutes before the fan is turned on.
This is to ensure that when the fan
starts, only cool air enters the building.
ILL1085-A
4SEELEY INTERNATIONAL – OWNER’S MANUAL
AUTOMATIC MODE
MANUAL MODE
The AUTO button is used to select
Automatic mode or Manual mode.
When “Auto” is displayed the cooler is
under Automatic control and will
operate according to the temperature
sensed at the wall control.
When the air cooler is turned on, it will
read the temperature and set the
cooler operation accordingly. If the
temperature increases at the wall
control, then the fan speed will
increase. As the temperature
decreases the fan speed will decrease
until the cooler turns off.
Press or to overide the
automatic cooling level setting and
adjust your room temperature.
To switch to Manual mode, press
AUTO until “Man” appears in the
display. In Manual mode the cooling
level can be manually adjusted.
In Manual mode, press to
choose between circulating cool air or
uncooled air. When “Cool” is
displayed, fresh cool air will circulate
into the building. When “Vent” is
displayed as shown, fresh uncooled
air will circulate through the building.
Press to increase the fan speed
and circulate more air. Press to
decrease the fan speed and circulate
less air. Press once to change the
speed by one increment. Hold the
button down to change the speed
more quickly.
COOL
AUTOMATIC MODE DISPLAY
MANUAL MODE DISPLAY

5CPL Evaporative Cooler
®
TIMED AUTOMATIC START
TIMED AUTOMATIC STOP
You can set the air cooler so that it will
turn on after a set number of hours.
1.To set the delayed start time, press
with the cooler turned OFF.
“Starting in” will be displayed as shown
with the last mode of operation (Manual
or Automatic).
2.If you want the air cooler to turn on in
Automatic mode with the previous
settings, then press until “Auto”
is displayed. Alternatively, if you want
the air cooler to turn on in Manual
mode, press until “Man” is
displayed and then press and
then or to set the required fan
speed.
3.To set the time until the start, press
.
4.Then press or to adjust the
time. The cooler can start up to 24
hours in advance.
5.Press again to initiate the
timed automatic start. The timed start
will not repeat.
You can also set the air cooler so that it
will turn off after a set number of hours.
1.To set a delayed stop time, press
with the cooler running.
”Stopping in” will display.
TIMER
AUTO
AUTO
COOL
TIMER
TIMER
TIMER
2.Press or to adjust the
number of hours before the air
cooler will stop. The maximum
delay setting is 24 hours.
3. Press again to begin
the timed stop.
TIMER
6SEELEY INTERNATIONAL – OWNER’S MANUAL
USING THE COOLER
Now that you have read these
instructions, press the
button to turn your air cooler on. If
the air cooler has not operated for
a while , “Pre Cool Cycle” will flash
on the display. The “Pre Cool Cycle
will begin and will take only a few
minutes to complete. After this
time, the fan will come on
automatically, and you can enjoy
the comfort of cool fresh air!
POWER AIR TOO COLD
With the cooler running in Automatic
mode, you may find that you are too
cold or that the air cooler is blowing
too much air. Press to lower the
automatic temperature setting and
reduce the amount of cooling.
If you are too cold with the cooler
running in Manual mode, then press
to reduce the fan speed. You can
also circulate fresh uncooled air by
pressing until “Vent”displays.COOL
AIR NOT COLD ENOUGH
You may find that with the air cooler
running in Automatic mode, you are
not cool enough. Simply press to
increase the cooling rate.
If you are not cool enough with the
air cooler running in Manual mode,
then press to increase the fan
speed. Ensure that cooled air is
circulating by pressing until
“Cool”displays.
COOL
You can experiment with the
settings on your wall control.
This is the best way to get the
most from your air cooler.

5CPL Evaporative Cooler
®
TIMED AUTOMATIC START
TIMED AUTOMATIC STOP
You can set the air cooler so that it will
turn on after a set number of hours.
1.To set the delayed start time, press
with the cooler turned OFF.
“Starting in”will be displayed as shown
with the last mode of operation (Manual
or Automatic).
2.If you want the air cooler to turn on in
Automatic mode with the previous
settings, then press until “Auto”
is displayed. Alternatively, if you want
the air cooler to turn on in Manual
mode, press until “Man”is
displayed and then press and
then or to set the required fan
speed.
3.To set the time until the start, press
.
4.Then press or to adjust the
time. The cooler can start up to 24
hours in advance.
5.Press again to initiate the
timed automatic start. The timed start
will not repeat.
You can also set the air cooler so that it
will turn off after a set number of hours.
1.To set a delayed stop time, press
with the cooler running.
”Stopping in”will display.
TIMER
AUTO
AUTO
COOL
TIMER
TIMER
TIMER
2.Press or to adjust the
number of hours before the air
cooler will stop. The maximum
delay setting is 24 hours.
3. Press again to begin
the timed stop.
TIMER
6SEELEY INTERNATIONAL – OWNER’S MANUAL
USING THE COOLER
Now that you have read these
instructions, press the
button to turn your air cooler on. If
the air cooler has not operated for
a while , “Pre Cool Cycle”will flash
on the display. The “Pre Cool Cycle
will begin and will take only a few
minutes to complete. After this
time, the fan will come on
automatically, and you can enjoy
the comfort of cool fresh air!
POWER AIR TOO COLD
With the cooler running in Automatic
mode, you may find that you are too
cold or that the air cooler is blowing
too much air. Press to lower the
automatic temperature setting and
reduce the amount of cooling.
If you are too cold with the cooler
running in Manual mode, then press
to reduce the fan speed. You can
also circulate fresh uncooled air by
pressing until “Vent”displays.COOL
AIR NOT COLD ENOUGH
You may find that with the air cooler
running in Automatic mode, you are
not cool enough. Simply press to
increase the cooling rate.
If you are not cool enough with the
air cooler running in Manual mode,
then press to increase the fan
speed. Ensure that cooled air is
circulating by pressing until
“Cool”displays.
COOL
You can experiment with the
settings on your wall control.
This is the best way to get the
most from your air cooler.

7CPL Evaporative Cooler
®
This cooler comes with a standard
bleed system or the optional automatic
Drain Valve.
STANDARD BLEED SYSTEM
During operation, the bleed system will
drain small amounts of water. This
ensures fresh water is continually
added to dilute salt accumulation in the
water caused through evaporation. This
helps keep the air cooler in good
condition and ensure optimum
performance. The bleed rate will
depend on local operating conditions
and will be set by the installer.
AUTOMATIC DRAIN
VALVE
If the drain valve was installed
instead of the standard bleed
system then your cooler will
automatically drain after a set
time of continuous operation.
This ensures the water is
always fresh and helps
maintain your cooler in good
condition to ensure optimum
cooling performance. The
frequency of the automatic
drain may have been adjusted
by your installer according to
the general water quality in your
area.
When the cooler is turned off for
72 hours, the drain valve will
open automatically and empty
water from the cooler. When the
cooler is turned on again, fan
operation will delay for a few
minutes while the tank refills
and the cooling pads are
saturated again.
At any time when the
thermostat is OFF, you can
drain the cooler by pressing
and holding s and t for 1
second. The display will show
“dr”to confirm the operation has
activated.
8SEELEY INTERNATIONAL – OWNER’S MANUAL
MAINTENANCE
HEALTH REGULATIONS
END OF SEASON SERVICE
Regular maintenance is essential to
ensure the cooler operates efficiently
for many years. Services must be
performed before and after the
summer season. More frequent
servicing may be required in dusty
conditions or in areas with poor water
quality.
Note that some regulating authorities
require services to be conducted at
specific intervals.
•Turn off the power supply to the
cooler.
•Turn off the water supply to the
cooler.
•Remove the pad frames as shown.
•A. Turn off the power switch inside
the cooler.
•B. Check and clean the lid water
channels .
•C. If fitted, first unclip and then
remove the bleed system as shown.
Allow the tank water to drain. Do not
lose the o-ring.
•Thoroughly clean the tank and pump
filter.
WARNING: We recommend
maintenance is carried out by an
authorised service agent. Climbing
onto the roof is hazardous and can
result in personal injury or property
damage. Failure to carry out
maintenance will affect your
warranty coverage.
A
B
C
•Do not replace the bleed system.
(If a Drain Valve is fitted it will
automatically drain.)
•Re-fit the pad frames.

7CPL Evaporative Cooler
®
This cooler comes with a standard
bleed system or the optional automatic
Drain Valve.
STANDARD BLEED SYSTEM
During operation, the bleed system will
drain small amounts of water. This
ensures fresh water is continually
added to dilute salt accumulation in the
water caused through evaporation. This
helps keep the air cooler in good
condition and ensure optimum
performance. The bleed rate will
depend on local operating conditions
and will be set by the installer.
AUTOMATIC DRAIN
VALVE
If the drain valve was installed
instead of the standard bleed
system then your cooler will
automatically drain after a set
time of continuous operation.
This ensures the water is
always fresh and helps
maintain your cooler in good
condition to ensure optimum
cooling performance. The
frequency of the automatic
drain may have been adjusted
by your installer according to
the general water quality in your
area.
When the cooler is turned off for
72 hours, the drain valve will
open automatically and empty
water from the cooler. When the
cooler is turned on again, fan
operation will delay for a few
minutes while the tank refills
and the cooling pads are
saturated again.
At any time when the
thermostat is OFF, you can
drain the cooler by pressing
and holding s and t for 1
second. The display will show
“dr”to confirm the operation has
activated.
8SEELEY INTERNATIONAL – OWNER’S MANUAL
MAINTENANCE
HEALTH REGULATIONS
END OF SEASON SERVICE
Regular maintenance is essential to
ensure the cooler operates efficiently
for many years. Services must be
performed before and after the
summer season. More frequent
servicing may be required in dusty
conditions or in areas with poor water
quality.
Note that some regulating authorities
require services to be conducted at
specific intervals.
•Turn off the power supply to the
cooler.
•Turn off the water supply to the
cooler.
•Remove the pad frames as shown.
•A. Turn off the power switch inside
the cooler.
•B. Check and clean the lid water
channels .
•C. If fitted, first unclip and then
remove the bleed system as shown.
Allow the tank water to drain. Do not
lose the o-ring.
•Thoroughly clean the tank and pump
filter.
WARNING: We recommend
maintenance is carried out by an
authorised service agent. Climbing
onto the roof is hazardous and can
result in personal injury or property
damage. Failure to carry out
maintenance will affect your
warranty coverage.
A
B
C
•Do not replace the bleed system.
(If a Drain Valve is fitted it will
automatically drain.)
•Re-fit the pad frames.

9CPL Evaporative Cooler
®
PRE-SEASON SERVICE
REMOVAL OF PAD FRAMES
•Turn off the power supply to the air
cooler
•Remove the pad frames as shown.
•Ensure the power switch in the cooler
is off.
•Gently wash the pads to remove any
dust build up during the winter period. If
the pads are in poor condition, replace
them.
•Replace the bleed system if it was
removed during previous maintenance
and ensure the o-ring is fitted. (If the
cooler is fitted with a drain valve this will
not be necessary as it will automatically
close when the cooler turns on).
•Turn on the power switch inside the
cooler.
•Turn on the water and then the power.
•Re-fit the pad frames and run the
cooler.
To remove a pad frame, insert a flat
screw driver tip into the slot as shown
and lever until disengagement occurs.
Take hold of the pad frame and pull it
towards you until the internal side clips
disengage.
Pivot the pad frame outwards and lift
up. Take care not to damage the pad.
Repeat these steps for the remaining
pad frames.
IMPORTANT: Do not damage the
pads with high pressure water spray.
WARNING: Do not run the air cooler
with the pad frames removed.
10SEELEY INTERNATIONAL – OWNER’S MANUAL
PROBLEM – Unpleasant Odour
CAUSE ACTION
1. Odour from new pads. Allow time to condition by running the
air cooler.
PROBLEM – Inadequate Cooling
CAUSE ACTION
1. Dry pads. Check water flow to pads.
Inspect fitment of distributor cap.
Check for blocked or kinked hose. If
blocked, dismantle, clean and flush or
unkink the hose.
2. Insufficient exhaust
openings for conditioned
air.
Ensure sufficient openings. Refer to
chart on Pg. 2
3. Excessive ambient
humidity
(See also Insufficient
exhaust)
On days where the ambient humidity
is high, the cooler will not reduce the
temperature as much as on drier
days.
If your wall control displays SERVICE or should you consider that your
cooler requires service, contact your local Dealer or the Service number on
the back of this manual.
TROUBLE-SHOOTING GUIDE

9CPL Evaporative Cooler
®
PRE-SEASON SERVICE
REMOVAL OF PAD FRAMES
•Turn off the power supply to the air
cooler
•Remove the pad frames as shown.
•Ensure the power switch in the cooler
is off.
•Gently wash the pads to remove any
dust build up during the winter period. If
the pads are in poor condition, replace
them.
•Replace the bleed system if it was
removed during previous maintenance
and ensure the o-ring is fitted. (If the
cooler is fitted with a drain valve this will
not be necessary as it will automatically
close when the cooler turns on).
•Turn on the power switch inside the
cooler.
•Turn on the water and then the power.
•Re-fit the pad frames and run the
cooler.
To remove a pad frame, insert a flat
screw driver tip into the slot as shown
and lever until disengagement occurs.
Take hold of the pad frame and pull it
towards you until the internal side clips
disengage.
Pivot the pad frame outwards and lift
up. Take care not to damage the pad.
Repeat these steps for the remaining
pad frames.
IMPORTANT: Do not damage the
pads with high pressure water spray.
WARNING: Do not run the air cooler
with the pad frames removed.
10SEELEY INTERNATIONAL – OWNER’S MANUAL
PROBLEM – Unpleasant Odour
CAUSE ACTION
1. Odour from new pads. Allow time to condition by running the
air cooler.
PROBLEM – Inadequate Cooling
CAUSE ACTION
1. Dry pads. Check water flow to pads.
Inspect fitment of distributor cap.
Check for blocked or kinked hose. If
blocked, dismantle, clean and flush or
unkink the hose.
2. Insufficient exhaust
openings for conditioned
air.
Ensure sufficient openings. Refer to
chart on Pg. 2
3. Excessive ambient
humidity
(See also Insufficient
exhaust)
On days where the ambient humidity
is high, the cooler will not reduce the
temperature as much as on drier
days.
If your wall control displays SERVICE or should you consider that your
cooler requires service, contact your local Dealer or the Service number on
the back of this manual.
TROUBLE-SHOOTING GUIDE

seeleyinternational.com AU 1110
834962-H
Affix serial & model
number ker herestic
Warranty Service
Australia 1-300-650-644
seeleyinternational.com
It is the policy of Seeley International to introduce continual
product improvement. Accordingly, specifications are
subject to change without notice. Please consult with your
dealer to confirm the specifications of the model selected.
When you contact your Dealer regarding service
or warranty please quote the cooler model
number and serial number as shown below.
®