Coolmay BG200 User manual

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
Coolmay Gateway BG200
User Manual
Copyright: Shenzhen Coolmay Technology Co., Ltd
V23.21

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
Content
Product Description
I. Instructions before use ........................................................................................................................................ 1
1.1 Safety precautions .................................................................................................................................... 1
II. Introduction of Functional Parameters ...............................................................................................................3
2.1 Introduction to panel hardware and guide rail installation ........................................................................3
2.1.1 Panel introduction ...........................................................................................................................3
2.1.2 Hardware parameters .....................................................................................................................4
2.1.3 Guide rail installation ...................................................................................................................... 5
2.1.4 Guide rail disassembly ................................................................................................................... 6
2.2 Protocols supported by BG200 .................................................................................................................8
III. Networking .........................................................................................................................................................9
IV. Wiring diagram ................................................................................................................................................10
4.1 PLC wiring mode of Coolmay series ...................................................................................................... 10
4.1.1. L02 physical wiring diagram ........................................................................................................ 10
4.1.2 L02 actual wiring diagram ............................................................................................................ 11
4.2 Mitsubishi FX series PLC download port wiring mode ...........................................................................12
4.2.1 Mitsubishi FX series 422 physical wiring diagram ....................................................................... 12
4.2.2 Mitsubishi FX series 422 actual wiring method ............................................................................13
4.3 485 wiring (this interface is available for MODBUS RTU/FX series) .................................................... 14
4.3.1 485 physical wiring diagram ........................................................................................................ 14
4.3.2 485 actual wiring diagram ........................................................................................................... 15
4.4 S7-200SMART wiring ............................................................................................................................ 16
4.4.1 S7-200SMART Physical wiring diagram ..................................................................................... 16
4.4.2 S7-200SMART actual wiring diagram ......................................................................................... 17
V. Device binding ..................................................................................................................................................18
5.1 Log in Coolmay Cloud .............................................................................................................................18
5.2 Add device ...............................................................................................................................................19
5.3 Create template .......................................................................................................................................20
5.3.1 Coolmay PLC template ................................................................................................................20
5.3.2 Siemens S7-200 smart PLC template .........................................................................................21
5.4 Variables configuration ........................................................................................................................... 22
5.5 Communication module binding ............................................................................................................. 23
5.6 Tips ..........................................................................................................................................................27
5.7 Baud rate setting ..................................................................................................................................... 28
VI. Equipment Dashboard Editing ........................................................................................................................29
6.1 Configuration design ............................................................................................................................... 29
6.2 Background color .................................................................................................................................... 30
6.3 Numerical display ....................................................................................................................................31
6.4 Dash board ..............................................................................................................................................32
6.5 Water level chart ..................................................................................................................................... 34
VII. Equipment strategy ........................................................................................................................................ 36
7.1 Timed task ...............................................................................................................................................36
7.2 Independent configuration (multiple project-based equipment configuration functions in different
locations) ....................................................................................................................................................... 37
7.3 Device linkage .........................................................................................................................................37
VIII. Operation Center .......................................................................................................................................... 38
8.1 Device map ............................................................................................................................................. 38
8.2 Operational Dashboard ...........................................................................................................................38
8.2.1、Add device configuration interface ............................................................................................ 41
8.2.2、Add project configuration (independent configuration interface) .............................................. 42
8.2.3. Add device map ...........................................................................................................................43
8.2.4 Add real-time dynamic graph ....................................................................................................... 44
IX. Data center ......................................................................................................................................................45
9.1 History (query) .........................................................................................................................................45
9.2 History (export) ........................................................................................................................................47

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
9.3 Device online and offline (device online and offline record query) ........................................................ 49
9.4 Alarm record (query) ............................................................................................................................... 50
9.5 Alarm log (export) ....................................................................................................................................50
9.6 Report management ............................................................................................................................... 50
9.7 Data analysis ...........................................................................................................................................50
X. Message center ................................................................................................................................................51
10.1 Inbox ......................................................................................................................................................51
10.2 Notification strategy (WeChat alarm function) ......................................................................................52
10.2.1WeChat alarm function introduction ............................................................................................ 52
10.2.2、WeChat alarm configuration steps .......................................................................................... 53
10.3 Alarm point configuration ...................................................................................................................... 57
XI. WeChat Mini Programs ...................................................................................................................................59
XII. Gateway usage steps (beginners must read) ............................................................................................... 60
12.1 Operation steps of CX3G and BG200 (all Coolmay PLCs can be operated according to this step) .. 60
XIV. Remote upload and download ..................................................................................................................... 71
13.1 Install the transparent transmission software BoxManager ................................................................. 71
13.2 Serial port remote download .................................................................................................................74
13.3 Remote download via network port ...................................................................................................... 79

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
Product Description
Equipment introduction:
顾美通用性云网关,是一款网口串口都通用的网关,主要针对国内外工控设备的应
用而诞生,能够应付市场上各类模块例如:仪表、模拟量模块、通讯传感器、智能控制
模块、各种PLC、各种工控设备,将其设备数据全部实现远程数据读写,从而简单的实
现控制远程的设备,控制的方式很多种,例如电脑控制、微信公众号监控报警数据、手
机APP微信小程序控制,以及组态使用功能。并且可以用顾美云实现云组态功能,让数
据实时展示在远处大公屏幕上,并且支持有线传输、WIFI传输、4G传输等网络传输方
式;
在云平台上面还可以做出一系列的云平台管理系统,可以申请报修提示功能,微信
告警提示功能、数据在线查询功能、数据导出功能、地图定位功能、数据报表、报警数
据在线查询导出、实时查看设备的在线上下线运行状况、并有柱状图、曲线图、可以指
定时间查看该时间的多种数据走势;
Coolmay universal cloud gateway is a gateway that is universal for both network
and serial ports. It is mainly designed for the application of industrial control equipment
at home and abroad. It can cope with various modules in the market, such as
instruments, analog modules, communication sensors, intelligent control modules,
various PLCs, and various industrial control equipment. It can read and write all its
equipment data remotely, so as to simply control remote equipment in many ways, For
example, computer control, WeChat official account monitoring alarm data, mobile
phone APP WeChat applet control, and configuration use function. In addition, the
Coolmay cloud can be used to realize the cloud configuration function, so that the data
can be displayed on the remote public screen in real time, and it supports wired
transmission, WIFI transmission, 4G transmission and other network transmission
methods;
On the cloud platform can also make a series of cloud platform management
system, can apply for repair prompt function, Wechat alarm prompt function, data
online query function, data export function, map positioning function, data report, alarm
data online query export, real-time view of the device online up and down running
status, and with a bar chart, curve, you can specify a time to view a variety of data
trends at the time.
Remote Gateway BG200

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
Main functions and characteristics of the equipment:
Standard 485 interface, supporting standard MODBUS RTU protocol
Standard RJ45 interface, supporting standard MODBUS TCP protocol
MODBUS protocol supports up to 32 slave stations
Standard 232 DB9 interface, supporting data acquisition interface
Cloud platform configuration function
Mobile WeChat applet
remote control send value
Communication alarm function WeChat official account push alarm function
Push alarm function for specified size change of data
Data online and offline query function
Alarm record query and export function (no upper storage limit temporarily)
Historical data query and export function (there is no upper storage limit temporarily)
Device data interaction function
Functional characteristics

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
1
I. Instructions before use
1.1 Safety precautions
1.2 Precautions for installation and wiring
Safety first
Remote gateway BG200

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
2
Remote gateway BG200
Safety first

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
3
II. Introduction of Functional Parameters
2.1 Introduction to panel hardware and guide rail installation
2.1.1 Panel introduction
Note: Do not connect the WAN port and the LAN port to the same switch or router when use WAN
port networking
Remote gateway BG200

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
4
2.1.2 Hardware parameters
Product specification:
Model
→
BG200
Rated power
→
< 5W
Rated voltage
→
DC9-38V working voltage
Maximum power
consumption
→
12W
Working temperature
→
-10~60℃
Ambient humidity
→
10~90%RH (no condensation)
Networking method ①
→
4GSIM Telecom/Unicom/Mobile
Networking method ②
→
Ethernet
Networking method ③
→
Wi-Fi
CPU
→
580MHz MIPS
RAM
→
16MB Flash + 128MB DDR2
VPN
→
Support
Ethernet
→
1个WAN,2个LAN
Serial port
→
RS232 / RS485
Dimensions
→
106mm * 97mm * 23mm
(not including antenna and mounts)

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
5
2.1.3 Guide rail installation
①Select the installation location of the equipment to ensure that there is enough
space.
②Take out the attached screws and metal buckle. Install the buckle on the
machine body with screws.
③The buckle can be directly installed on the guide rail after installation.
Note: The guide rail is 35mm standard guide rail, which needs to be equipped by
itself
Fig.2.1.3.1

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
6
2.1.4 Guide rail disassembly
The specific steps are as follows:
①As shown by the arrow 1 in Figure 4-2, press the equipment downward to make the lower end of
the equipment free from the DIN rail.
②Turn the equipment in the direction of arrow 2, and move the lower end of the equipment outward
at the same time. After the lower end is separated from the DIN rail, lift the equipment upward to
remove the equipment from the DIN rail.
Fig. 2.1.4.1

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
7
2.1.5 Structural dimensions
Note: The structure size does not include the wiring part and terminal antenna part
Fig. 2.1.5.1

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
8
2.2 Protocols supported by BG200
Interface
Protocols
Support
or not
485
232
RJ45
Siemens SMART200
yes
√
Mitsubishi FX1/2/3 series
yes
√
Mitsubishi Q/5U
yes
√
Coolmay series PLC
yes
√
√
MODBUS RTU protocol
yes
√
MODBUS TCP protocol
yes
√

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
9
III. Networking
BG200 supports 3 modes of connecting to the cloud:
①Connect the WAN port of BG200 to the network interface to automatically acquire the network
without modifying the parameters;
②BG200 has a built-in 4G card slot. Inserting the 4G card into the card slot can automatically
acquire 4G network signals. It supports mobile, Unicom and telecom cards. Direct access can
automatically acquire the network without any parameter settings;
③WIFI needs to link to the local WIFI network, and the configuration method is linked by the
specified method;
Note:
WAN port is the connection port to connect the network
LAN port is used to connect industrial control equipment

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
10
IV. Wiring diagram
4.1 PLC wiring mode of Coolmay series
4.1.1. L02 physical wiring diagram
Pin-Definition
Gateway
PLC
Sending end
2
5
Receiving end
3
4
GND
5
8
The default PLC download port of each series of
Coolmay is 232 interface, which needs to be
connected with standard cable. Use DB9 mouse
header 232, defined in the table above;
Communication method ①DB232 connect to
round head 232 (standard communication method)
Communication method ②AB port of the gateway
connect to the AB port/A2B2 port of the PLC
Communication method ③The network port of the
gateway connect to the network port of the PLC
Protocol selection: Modbus/Coolmay-3G-L02
series - serial port

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
11
4.1.2 L02 actual wiring diagram
Pin-Definition
Gateway
PLC
Sending end
2
5
Receiving end
3
4
GND
5
8

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
12
4.2 Mitsubishi FX series PLC download port wiring mode
4.2.1 Mitsubishi FX series 422 physical wiring diagram
Gateway
232
Convert
422
PLC
2
1
3
2
5
4
7
To connect with the Mitsubishi FX series
PLC interface, you can directly use the 232
to 422 dedicated line, or use the above
table for terminal wiring;
Protocol selection: Modbus/Mitsubishi-FX
series-serial port

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
13
4.2.2 Mitsubishi FX series 422 actual wiring method
Gateway
232
Convert
422
PLC
2
1
3
2
5
4
7

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
14
4.3 485 wiring (this interface is available for MODBUS RTU/FX series)
4.3.1 485 physical wiring diagram
BG200
Inverter
A
485-
B
485+
The AB port of BG200 can be connected to
various industrial control equipment
(equipment supporting MODBUS RTU
protocol and Mitsubishi PLC supporting FX
series)
Protocol selection: Modbus/Modbus/Modbus
RTU

Coolmay Gateway BG200 User Manual
www.coolmayplc.com
15
4.3.2 485 actual wiring diagram
Table of contents