3. 520r PIR
Installation
Open the detector by lifting the flap and removing the screw from the case.
Install two ‘AA size alkaline batteries (not supplied). Do not use rechargeable (Nickel
Cadmium) batteries, because they are 1.2V and not 1.5V.
Learning
See “Programming - Learning Detectors” in the 500r+ Installer’s Guide.
Testing.
1. Put 500r Wirefree Control Panel into walk test (user code + 1).
2. Open and close the tamper for each detector (this will start the test mode).
Note: After opening and closing the tamper, the detector remains in test mode for half an
hour. In this mode the detector has a 30 second lockout time. At the end of half an hour the
detector reverts to normal mode, with a 3 minute lockout time.
3. Make sure the panel receives the alarm from each detector.
4. Chose another site for the detector if the panel does not receive the signal.
5. Wait thirty seconds with no movement in front of the detector before triggering it
again.
6. Press RESET on the control panel when you have finished testing, to put the panel
back into user mode.
4. 520r PIR
Walk Testing and Lockout
In normal use the 520r uses a three minute lockout timer in order to extend battery life. The
lockout timer works like this:
a) The unit detects movement, signals the panel, and starts the lockout timer.
b) If the unit detects movement while the lockout timer is running, then it restarts the
lockout timer but DOES NOT signal the panel.
c) When the lockout timer expires the unit signals the panel the next time it detects
movement.
If you want to test a 520r PIR in normal use you should wait at least three minutes between
activations. To make testing easier the detector changes the lockout period to 30 seconds for
the first half hour after you put the batteries in, or after you trigger its tamper.
Mount the back
There are a number of possible fixing holes in the back of the PIR marked by mouldings in
the plastic. Chose two to suit the location you have selected, and drill them out carefully.
1. Hold the back in location and mark and drill 5 fixing holes in the wall.
2. Secure the back to the wall with 16mm countersunk head screws and wall plugs.
3. Clip the body of the detector to the back.
5. 525r Remote Setting Device
Introduction
The user can employ the 525r Remote Setting Device to set, un-set and part set the 500r
Wirefree Control Panel. In addition, pressing Arm and Off at the same time will cause a Panic
Alarm. The 500r Wirefree Control Panel can use up to three 525r Remote Setting Devices.
Specification
Part No. 525rEUR-00
Power Supply Duracell DL 1/3N or CR 1/3N or K58L (Alkaline)
RS Part No. 596-040. Farnell Part No. 300-469
Battery Life Approximately 14 months.
Temperature Range -10 to +50 °C
Learning
The control unit stores the Remote Setting Device’s identity in the same “hidden” zone as
the 502r PAs and 524r keypads. The 500r+ can learn any mixture of keypads, 502 PAs, or
Remote Setting Devices provided the total number of devices does not exceed six.
See “Programming - Learning Detectors” in the 500r+ Installer’s Guide.
Changing the Battery
1. Undo the screw holding down the battery compartment cover.
2. Slide back the cover.
3. Replace the battery (make sure the battery polarity is correct).
4. Replace cover and tighten screw (do not overtighten).
Note: The battery can be obtained from Cooper Security Limited Service Department.
6. 525r Remote Setting Device
© Cooper Security Limited 2004
Every effort has been made to ensure that the contents of this leaflet are correct . However,
neither the authors nor Cooper Security Limited accept any liability for loss or damage caused
or alleged to be caused directly or indirectly by this leaflet. The contents of this leaflet are
subject to change without notice.
Printed and published in the U.K.
PIR
Remote Setting
Device
Universal
Transmitter
Keypad
Pendant
Installation Guide
Cooper Security Ltd
Security House
Vantage Point Business Village
Mitcheldean
Gloucestershire
GL17 0SZ
Product Support (UK) Tel: +44 (0) 870 757 5400. Hours:
08:15 to 17:00 Monday to Thursday,
08:15 to 12:45 Friday.
12:45 to 17:00 Friday emergency service only.
(CALLS CHARGED AT 60p PER MINUTE)
Product Support Fax: (01594) 545401
Part No. 496926 Issue 1
-ve terminal
Battery +ve terminal
520r, 525r, 536r, 524r, 502r
DECLARATION OF CONFORMANCE
Cooper Security Ltd issues this certificate
to certify that the equipment know as:
515r, 525r, 535r, 524r and 502r
Complies with the following directive:
1995/5/EC R&TTE Directive
Signed
Stewart Taylor, Technical Director
Date: 12 January 2004