Intelligent Addressable Product Range
Passive Repeater Panel DF6000PR
verview
The DF6000PR is a cost effective passive repeater
panel which can be programmed via its informative
display to be either fully passive (display only) or
semi passive (restricted system control).
When loop connected the repeater panel will display
the system information text of the connected control
panel and will provide a fire indication, with panel
number, of any connected network control panel that
has fire activation.
The F6000PR repeater panel only requires
programming with local text information.
In addition to the repeater panels main menu driven
2 x 40 backlit LC display, which provides system
status information, it also has 6 supervisory LE ’s
(Power On, Alarm, Trouble, Supervisory, Test In
Progress, and Scroll).
2 x 40 backlit LC display and 6 supervisory LE ’s
Features
• Up to 20 repeaters can be
connected to the loop
• 2 x 40 backlit LC display and
6 supervisory LE ’s
• Compact size
• Can be surface or semi-
recessed mounted
Benefits
• Menu driven easy to operate
• Simple connection to panel
loop circuit reduces wiring and
installation time
• istance run up to 2km from
main panel without additional
cable and equipment, saving
cost
simple user interface F6000PR passive repeater panel
cfs0018_UK_R1_menvier-data-sheets_Lay ut 1 04/08/2011 12:05 Page 61
Intelligent Security & Fire Ltd
Cooper Lighting and Safety Ltd, Wheatley Hall Road, Doncaster, South orkshire, DN2 4NB. UK.
T: +44 (0) 1302 303350 l F: +44 (0) 1302 303332 l E: [email protected] l W: www.cooperfire.com
Intelligent Addressable Passive Repeater Panel - DF6000PR
Code CF30000PR
escription Passive repeater panel
Standards EN54 Pt4
Specification
Mains Input Voltage 230V ac +10% / -15%
Operating Voltage 24V dc
System Indicators Power on, fire, fault, test, disable and scroll
System Controls Silence alarms, evacuate and reset
Input Ports RS232 (for connection of programmer)
Battery 1 x 12V 3.2Ah
Standby uration 24 hours
Environmental
Operating Temperature 0°C to +25°C
Humidity (Non Condensing) 0 to 75% RH
Physical
Construction PC/ABS
Colour Light Grey
imensions (H x W x ) 332mm x 270mm x 92mm
Weight 3.6kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier intelligent addressable fire systems
Technical Specification
Installation
1. Wall mounted by means of 4 fixing screws.
2. Cable entry at top or back.
3. 12 top entry gland holes with push out blanking
plugs.
4. 4 separate rear access cable entry facilities.
5. Local mains supply required.
System Functionality
1. Panel operates in either normal, supervisor or
engineer mode.
2. Supervisor and engineer modes are accessed via
4 digit pass codes.
3. Supervisor mode allows silence, evacuate and
reset commands to be sent to host panel (loop
connected) or to network (network connected).
4. Engineer mode enables password to be changed if
required and allows access to text download menu
5. When connected to network, all text is transmitted
via network, changes to other network panels
update automatically.
6. When connected to a detector
loop, text for host is
downloaded to repeater and
updated manually as required.
7. Zonal fire and fault indication is
by means of 2 x 40 character
LC display.
Device verview
1. Panel can be connected to
either the detection loop of a
single panel or to a network as
part of a networked system.
2. Supplied with integral power
supply and standby battery.
Dimensions
W
H
D2
D1
12345
SCROLLMUTE
BUZZER
H (mm) W (mm) D1 (mm) D2 (mm)
270 332 45 47
Code Description
F6000PR Intelligent addressable passive repeater panel, loop connected
F6000PRNC Intelligent addressable passive repeater panel, network connected
Product Codes
Mains Supply
Network Link
Mains Supply
Mains Supply
Network Link
Loop Connected
Network Connected
Note: In this configuration the repeater would give
‘text’ information for the panel that is on the
loop, but only address number for the other
panel on the network.
Standard Connection
-+
SCREEN
-+
SCREEN
LOOP
OUT
LOOP
IN
SCREEN
Tx +
Tx -
Rs485
MIMIC
TEXT DOWNLOAD
cfs0018_UK_R1_menvier-data-sheets_Lay ut 1 04/08/2011 12:05 Page 62
Intelligent Security & Fire Ltd

Popular Repeater manuals by other brands

Dekolink MW-BDA-ESMR-25W90 806-15 Hardware manual

Dekolink

Dekolink MW-BDA-ESMR-25W90 806-15 Hardware manual

GoMax Electronics CV-5005Z-G user manual

GoMax Electronics

GoMax Electronics CV-5005Z-G user manual

Homeworks HR-REP-SW installation instructions

Homeworks

Homeworks HR-REP-SW installation instructions

Relcom CBR-2AC installation instructions

Relcom

Relcom CBR-2AC installation instructions

DCB PR-6606 user guide

DCB

DCB PR-6606 user guide

SKYDANCE EV3-H Installation

SKYDANCE

SKYDANCE EV3-H Installation

Collingwood Lighting PR3002 Wiring diagrams

Collingwood Lighting

Collingwood Lighting PR3002 Wiring diagrams

Norman RPT01 quick start guide

Norman

Norman RPT01 quick start guide

Stahl 9186 5-12-11 Series operating instructions

Stahl

Stahl 9186 5-12-11 Series operating instructions

PureTools PT-R-HD21 user manual

PureTools

PureTools PT-R-HD21 user manual

Aztech WL580E user manual

Aztech

Aztech WL580E user manual

Pettinaroli U2WA Technical specifications

Pettinaroli

Pettinaroli U2WA Technical specifications

ICP DAS USA I-7531-FD quick start

ICP DAS USA

ICP DAS USA I-7531-FD quick start

Diamond Multimedia WR300N quick start guide

Diamond Multimedia

Diamond Multimedia WR300N quick start guide

golmar RD-V2PLUS instruction manual

golmar

golmar RD-V2PLUS instruction manual

Solt SR5-BPR user guide

Solt

Solt SR5-BPR user guide

Globalmediapro IP04R user manual

Globalmediapro

Globalmediapro IP04R user manual

Gembird WNP-RP-002 installation manual

Gembird

Gembird WNP-RP-002 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.