The LED Floodlight comes with a connection port which can accommodate a plug-in PIR or
Photocell. These are sold separately and can be purchased via your local retailer.
Testing PIR:
Turn the SENS dial anti-clockwise to the maximum point, turn the TIME dial clockwise to the minimum point, turn the LUX dial
clockwise to the Sun.
When you switch on the power, the fitting will not illuminate. After a 30 second pre-heat, when the sensor gets the induction signal, the
load will turn on. Once the load switches off, it will then turn on again after 5-15 seconds of the sensor receiving an induction signal.
After the sensor goes off, trigger the detection field after 5-10 seconds. The load should work. When there are no induction signals in the
sensor, the load should stop working
Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and sensor should not work when
testing in daylight. If you cover the detection window with an opaque object, the load should work. Under no induction signal condition,
the load should stop working within 5-15 seconds.