manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Core Products
  6. •
  7. Floodlight
  8. •
  9. Core Products CP-10WFLCW-AC User manual

Core Products CP-10WFLCW-AC User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LED Floodlight Instructions
Please read these instructions carefully and keep in a safe place for future reference.
Safety:This is a mains voltage powered product and should only installed by a qualified electrician.
Diagram:
Specification:
Voltage
AC180-240V
Power factor
>0.9
Wattage
10W
20W
30W
50W
100W
Lumen
>80LM/W
Lamp type
Epistar SMD 2835
CRI
>80
Material
Aluminium Alloy
Beam angle
180 °
Products size
103x155x23
121x163x23
160x193x26
206x216x31
270x260x33
(mm)
Colour Temp
Warm white: 2700-3000K, Cool White: 4000-4500K, Daylight: 6000-6500K
Work Temp
-20
℃
----50
℃
Protection
IP65
Housing colour
Black, White
PIR Specification:
Power Source:220-240VAC
Power Frequency:50/60Hz
Rated load: MAX. 100W resistive load / MAX.10W Inductive load
Detection Range: 90°
Detection Distance: 6-10m (adjustable);
Time Delay: min: 10±5sec, Max:8±2min. (adjustable)
Ambient Light: 2-2000lux. (adjustable)
Detection Motion Speed:0.6-1.5m/s
Working Temperature: -10℃--+40℃
Installation Height: 1-3m
Installation:
1-Remove the bracket pulling out the two bolts on both sides. 2- Fix the bracket throughout its holes
4-Fix the body to the bracket, adjust the angle
The LED Floodlight comes with a connection port which can accommodate a plug-in PIR or
Photocell. These are sold separately and can be purchased via your local retailer.
Testing PIR:
Turn the SENS dial anti-clockwise to the maximum point, turn the TIME dial clockwise to the minimum point, turn the LUX dial
clockwise to the Sun.
When you switch on the power, the fitting will not illuminate. After a 30 second pre-heat, when the sensor gets the induction signal, the
load will turn on. Once the load switches off, it will then turn on again after 5-15 seconds of the sensor receiving an induction signal.
After the sensor goes off, trigger the detection field after 5-10 seconds. The load should work. When there are no induction signals in the
sensor, the load should stop working
Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and sensor should not work when
testing in daylight. If you cover the detection window with an opaque object, the load should work. Under no induction signal condition,
the load should stop working within 5-15 seconds.
PLEASE NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX DIAL TO THE (SUN)
POSITION, OTHERWISE THE SENSOR WILL NOT WORK!
Maintenance:
1. Before carrying out maintenance, please allow the product to cool down.
2. The electric protection class of this product is” I” so it needs to be earthed.
3. This product is IP65, so no internal cleaning is required.
4. If the housing of the led floodlight is too hot, pls power off and wait for it to cool before you touch it.
5. Please do not dispose of this floodlight in your household bin. WEEE has been paid and can be recycled via your point of purchase.
6. The fixture can’t be modified. Any modification WILL void the warranty and can make the product dangerous.
7. Luxlite Ltd shall not be responsible for any product damages caused by mounting procedures which are not in accordance with these
instructions.
8. Installation must be carried out by a professional.