1.User’s Guide For CR6 Remote Controller
1-1. Features
zBattery bank voltage display
zOutput power display
zError condition indicator(High Battery, Low Battery, Over Temperature, Over Load conditions)
zAction condition indicator(INV, GRID, POWER SAVING)
zFailed connection display
1-2. Specification
zInput Voltage : 10.5 – 30Vdc
zOperating Temperature Range : 0 – 40 ℃
zStorage Temperature Range : - 30 ℃- 70 ℃
zStand-By Current Draw : < 80mA
zApplicable Models : SK700 / 1000 / 1500 / 2000 / 3000 / ST Series (except ST600)
1-3. Introduction
zPower ON/OFF Switch:
Power ON/OFF switch is to turn the inverter on or off. You are supposed to hear one beep sound
every time you switch on or off.
zBattery voltage indicator:
This bar chart controls a light that will move up and down as the battery voltage changes. Ideally, the
voltage should remain in the green Ares of the bar chart. If the voltage goes into the red area at the
top and bottom of the graph, inverter may shut down.
zOutput power indicator:
The AC load watt chart indicates the power drawn from the power inverter by the load. Ideally, the
watt indicator should remain in the green & orange area of the bar chart.
If the OUTPUT POWER indicator is up to the red area of the bar, the light will flash and the inverter will
shut down for inverter safety.
zOver voltage indicator:
The over voltage indicator is to indicate that the power inverter shuts down because its input voltage is
above 12 / 24 VDC.
zUnder voltage indicator:
The under voltage indicator is to indicate that the power inverter shuts down because its input voltage is
below 12 / 24 VDC.
zOver temp indicator:
The over temp indicator is to indicate that the power inverter shuts down because of overheating.
The over temp indicator will be OFF when the power inverter cools down.
zOverload indicator:
The overload indicator is to indicate that the power inverter shuts down because of short circuit or
overload problems.
zINV. indicator:
The inv. indicator is to indicate that the inverter is ready.
zGRID indicator:
The GRID indicator is to indicate that you are using AC supply.
zPWR.SAV. Indicator:Power saving functions are described below: