Electronic vacuum switch PSA100C
1Display
Mode To select the different modes
+/- To change settings
LED output 1 & 2 Switching indicators
2 Switch output 1 adjustment
To adjust switch output 1 threshold, push the “mode” key
1 time.
The display is alternating between “H1” and the adjusted
value.
To change this adjustment, push “+/-” keys until the
requested value is displayed.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
To change this adjustment, push “+/-” keys to display the
requested value.
After 5 seconds, the chosen value registers
automatically and the screen returns to the vacuum
display.
3 Switch output 2 adjustment
To adjust the switch output 2 threshold, push the “mode”
key 2 times quickly.
The display is alternating between “H2” and the adjusted
value.
To change this adjustment, push “+/-” keys to display the
requested value.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
Mode
+
-
To adjust the hysteresis
h1, push the mode key.
The display is alterna-
ting between “h1” and
the adjusted value.
or
To adjust the hysteresis
h2, push the mode key.
The display is alterna-
ting between “h2” and
the adjusted value.
or
Attendre
5 sec.
- 1
46H1
+75H1
75
1xM
-
Attendre
5 sec.
- 2
46H2
+65H2
75
2xM
-
+-
07h1
75
Attendre
5 sec.
10h1
nc
no
+-
07h2
10
Attendre
5 sec.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
To adjust output 1
configuration, push
the “mode” key.
To change this adjust-
ment, push “+/-” keys.
NO or NC are
displayed.
or