CSL ACROBAT User manual

INS TA LL AT I ON G U I DE 1 AND 2 INCH IC/CHICAGO RATED HOUSING | ACROBAT
STEP 1 - FRAME INSTALL / HORIZONTAL ADJUSTMENT
SPREAD HANGER BARS TO APPROPRIATE DISTANCE. FASTEN WITH HARDWARE (BY OTHERS) TO PREVENT VERTICAL MOVEMENT OF FIXTURE.
T-BAR
ROUND (DOWNLIGHT) SHOWN.
FOLLOW SAME STEPS FOR SQUARE WOOD
1 INCH:
(67 x 67mm)
2 in
8
5
2 x
8
5
2 INCH:
(85 x 85mm)
3 in
8
3
3 x
8
3
3 INCH:
(112 x 112mm)
4 in
8
3
4 x
8
3
4 INCH:
(138 x 138mm)
5 in
8
3
5 x
8
3
1 INCH: 2 in (67mm)
8
5
2 INCH:
3 INCH:
4 INCH: 5 in (138mm)
3 in (85mm)
8
3
4 in (112mm)
8
3
8
3
READ AND FOLLOW ALL SAFETY INSTRUCTION! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Never connect components under load
Do not touch the yellow surface of the LED as it may
damage the light engine
WARNING: RISK OF ELECTRIC SHOCK
Before installation, servicing, or peforming routine
maintenace disconnect power by turning o the circuit
breakers both to the outlet box and to its associated
wall switch
Installation and service of luminaires should be
performed by a qualified licensed electrician in
accordance with all local and National Electical Codes
DO NOT install damaged product
Verify that supply voltage is correct by comparing it
with the luminaire label information
All wiring connections should be capped with UL
approved recognized wire connectors
WARNING: RISK OF INJURY
Allow luminaire to cool before servicing and
performing maintenace
Follow all manufacturer’s warnings and restrictions
for: driver type, mounting locations, replacement and
recycling
Wear safety glasses and gloves when installing,
maintaining or servicing
Avoid direct eye exposure to the light source while it
is on
Keep combustible material away from luminaire
Do not install insulation within 3” (76mm) of any part
of the luminaire or in a way that may entrap heat
WARNING: RISK OF FIRE
WARNING: RISK OF PRODUCT DAMAGE

STEP 2A - VERTICAL ADJUSTMENT
INS TA LL AT I ON G U I DE 1 AND 2 INCH IC/CHICAGO RATED HOUSING | ACROBAT
DOUBLE SIDE ADJUSTMENT / OUTSIDE
Loose the wing nuts to adjust the height of the housing, then tighten.
STEP 3 - MAKEELECTRICAL CONNECTION
Step 3-1 :
Remove knock out and
acess cover
Step 3-2 :
Must cut the cable
tie for transport.
Step 3-3 :
Make electrical
connection.

INS TA LL AT I ON G U I DE 1 AND 2 INCH IC/CHICAGO RATED HOUSING | ACROBAT
STEP 4A - CEILING CUTOUT
FOR TRIMLESS SEE 4B.
STEP 4B - MUD RING (TRIMLESS ONLY)
ATTACH MUD RING TO
CEILING WITH SCREWS.
COVER MUD RING WITH A
THIN LAYER OF FINISH PLASTER

STEP 2 - PREPARE THE MODULE
STEP 1 - MAKEELECTRICAL CONNECTIONAND INSTALL SAFETY HOOK
WARNING: DO NOT USE ASA HANGINGDEVICE.
DOING SO MAY RESULTIN DAMAGE OR INJURY
I N STA L L AT IO N G UI D E MODULE | ACROBAT
Step 2-1 :
Release the Screws
to this level.
Step 2-2 :
Locate the tool into the
module.
Step 2-3 :
Twist and lock the tool.

MODULE |
3A
I N STA L L AT IO N G UI D E ACROBAT
STEP 3 - INSTALL THE MODULE
Step 3-1 : Step 3-2 :
Aline the module
with the collar. (3A)
Insert the module to
the collar
Step 3-3 :
Twist and lock the
module clockwise.
(3B)
Step 3-4 :
Tighten the screws
to secure the
module. (3C)
Step 3-5 :
Twist and release
the tool anticlockwise.
()
3B 3C

MODULE |
4A
STEP 4 - TILT ANGLE ADJUSTMENT 0
°
~ 40
°
I N STA L L AT IO N G UI D E ACROBAT
Step 4-1 :
Release this two Screws
of Lock for Tilt.
Step 4-6 :
Tight two Screws of Lock
for Tilt.
Step 4-2 :
Insert screwdriver through
the first clip
Step 4-3 :
Push the screwdriver to the
heat sink
Step 4-4:
Insert screwdriver through the
second clip
Step 4-5 :
Use the Screwdriverand
adjust tilt angle, Scales on
the two side of module. (4A)

MODULE |
Step 5-1 :
Release the Screw
of Lock for Rotation.
Step 5-2 :
Adjust rotate.
STEP 5 - ROTATION ADJUSTMENT 360
Step 6-1 :
Locate the lens into the
module.
Step 6-2 :
Twist and lock the lens.
STEP 6 - INSTALL THE LENS
I N STA L L AT IO N G UI D E ACROBAT
Step 5-3 :
Tighten the Screw
of Lock for Rotation.
360º

STEP 1 - RELEASE THE REFLECTOR AND FLANGE
WARNING: TURN OFF THE POWER FIRST.
MAINTENANCE GUIDE IC HOUSING | ACROBAT
Twist and release the lens.
STEP 2 - RELEASE THE LENS
TRIMLESS: WALLWASH:

3A
Step 3-1 :
Release this two Screws
of Lock for Tilt.
Step 3-6 :
Tight two Screws of Lock
for Tilt.
Step 3-2 :
Insert screwdriver through
the first clip
Step 3-3 :
Push the screwdriver to the
heat sink
Step 3-4:
Insert screwdriver through the
second clip
Step 3-5 :
Use the Screwdriverand
adjust tilt angle to 0 ,
Scales on the two side of module. (2A)
STEP 3 - TILT THE MODULE
MAINTENANCE GUIDE IC HOUSING | ACROBAT

Step 4-1 :
Release the Screw
of Lock for Rotation.
Step 4-2 :
Rotate the module
Anticlockwise to the stop position.
STEP 4 - ROTATE THE MODULE
STEP 5 - REMOVE THE MODULE
Step 4-3 :
Tighten the Screw
of Lock for Rotation.
MAINTENANCE GUIDE IC HOUSING | ACROBAT
Step 5-1 :
Release the Screws
of Lock for safety
to this level.
Step 5-2 :
Twist and unlock the
module anticlockwise.
Step 5-3 :
Remove the module.

Step 7-1 :
Release the Screws
of driver plate,
and take out this two screws.
STEP 6 - RELEASE THE ELECTRICAL CONNECTION AND SAFETY HOOK
STEP 7 - RELEASE THE SCREWS OF DRIVER PLATE
MAINTENANCE GUIDE IC HOUSING | ACROBAT
Step 7-2 :
Pull out the driver plate.

STEP 8 - DRIVER REPLACEMENT
STEP 9 - PUT THE DRIVER PLATE BACK
Step 9-2 :
Tighten the Screws
of driver plate.
MAINTENANCE GUIDE IC HOUSING | ACROBAT
Step 9-1 :
insert the driver plate.

MAINTENANCE GUIDE IC HOUSING | ACROBAT
STEP 11 - PREPARE THE MODULE
STEP 10 - MAKEELECTRICAL CONNECTIONAND INSTALL SAFETY HOOK
WARNING: DO NOT USE ASA HANGINGDEVICE.
DOING SO MAY RESULTIN DAMAGE OR INJURY
Step 11-1 :
Release the Screws
of Lock for safety
to this level.
Step 11-2 :
Locate the tool into the
module.
Step 11-3 :
Twist and lock the tool.

MAINTENANCE GUIDE IC HOUSING | ACROBAT
12A
STEP 12 - INSTALL THE MODULE
Step 12-1 : Step 12-2 :
Aline the module
with the collar. (3A)
Insert the module to
the collar
Step 12-3 :
Twist and lock the
module clockwise.
(12B)
Step 12-4 :
Tighten the screws
to secure the
module. (12C)
Step 12-5 :
Twist and release
the tool anticlockwise.
()
12B12C

MAINTENANCE GUIDE IC HOUSING | ACROBAT
13A
STEP 13 - TILT ANGLE ADJUSTMENT 0
°
~ 40
°
Step 13-1 :
Release this two Screws
of Lock for Tilt.
Step 13-6 :
Tight two Screws of Lock
for Tilt.
Step 13-2 :
Insert screwdriver through
the first clip
Step 13-3 :
Push the screwdriver to the
heat sink
Step 13-4:
Insert screwdriver through the
second clip
Step 13-5 :
Use the Screwdriverand
adjust tilt angle, Scales on
the two side of module. (13A)

STEP 16 - INSTALL THE REFLECTOR AND FLANGE
MAINTENANCE GUIDE IC HOUSING | ACROBAT
Step 14-1 :
Release the Screw
of Lock for Rotation.
Step 14-2 :
Adjust rotate.
STEP 14 - ROTATION ADJUSTMENT 360
Step 15-1 :
Locate the lens into the
module.
Step 15-2 :
Twist and lock the lens.
STEP 15 - INSTALL THE LENS
Step 14-3 :
Tighten the Screw
of Lock for Rotation.
360º
Table of contents
Popular Light Fixture manuals by other brands

ColorKey
ColorKey stagepar 64 tri-cob user manual

Blizzard Lighting
Blizzard Lighting Blockhead II user manual

Cooper Lighting
Cooper Lighting Corelite 1T8 Specifications

Cooper Lighting
Cooper Lighting PM615cb Specification sheet

Philips
Philips ColorBlast 6 installation instructions

Hayward
Hayward AstroLite ll Spa Lighting manual

Knightsbridge
Knightsbridge EMSUR Installation & maintenance manual

Maximus
Maximus Smart Security Light SPL08-07A1N4-BKT instruction manual

LiteGear
LiteGear Cetara Office 6262 BAP 36-830-4320LM installation manual

Light Sky
Light Sky F400LL user manual

DOTLUX
DOTLUX CIRCLEugr-dim user manual

Acuity Brands
Acuity Brands Lithonia Lighting D-Series Wall installation instructions