DIP 2
ANTI MASK
Setting the DIP 2 Off we exclude anti-masking.
Set dip 2 in ON you turn on the front masking infrared active
If the dark field detection sensor and the dip 2 is ON, in a maximum
time of 10 seconds generates a tamper alarm (the output-mask open)
and remains in alarm as long as it remains the cause .
DIP3
AND
This function is activated setting DIP 3 in Off position. In this
configuration, when the two infrared sensors and the microwave
sensor detect a movement, the detector, will produce an alarm. This
mode is recommended in external environments with unstable
elements that could be produce false alarms.
OR
This mode is activated setting DIP 3 in Off position. In this
configuration, when one of the two infrared sensors and the
microwave sensor detect a movement, the detector will produce an
alarm. It is recommended in completely external environments and in
presence of small animals.
With this mode every small movement is detected.
DIP 4
MICROWAVE DE-ACTIVATION
DIP 4 in OFF. Microwave active.
DIP 4 in ON . Microwave de-activate.
This mode refers to the microwave alarm detection.
In particularly narrow environments ( such as garage passages,
gardens pedestrian areas) it is reccommended setting DIP 4 in On
position in order to have the infrared sensors detection only. If you
use this mode, you will always set DIP 3 in Off position (AND mode).
Let DIP 5 in ON position.