Current eFlux User manual

IMPORTANT: Please refer to additional safety warnings on last page.
- eFlux wave pumps create a tremendous amount of water flow. Do not install pump where the
strong current can harm corals or animals.
- Do not install pump too close to the sand bed where it will not stir/suck the sand.
- Pumps can also produce powerful waves in both wave and surge mode. Ensur
e your aquarium is
designed for wave pumps and ensure pumps ar
e mounted low enough not to push water out of the
aquarium.
- Magnet mounting assembly is very powerful. Be cautious not to cause injury to fingers.
- Keep out of reach of children.
- Never place magnets or pump near sensitive electronics, sharp objects or attractive surfaces.
- Never run wave pump dry or out of water.
- Always place spacer between magnets when not in use.
- Always unplug with dry hands for any maintenance or service.
- eFlux wave pumps are 24VDC. Ensure one 24VDC UL® transformer is used per wave pump.
- Ensure 24VDC UL® transformer is plugged into a GFCI approved outlet with a drip loop.
- Turn controller OFF and disconnect pump from power before performing any service
- Ensure eFlux wave pumps and any accessories all have a drip loop installed before plugging into
the wave pump manifold HUB as shown below.
SAVE THESE INSTRUCTIONS
AC Power
GFCI Outlet
24VDC
Power Supply
Wave Pump
LED Display
Wave Pump
Manifold HUB
P1P3 P2
LCK P/S SRE SUR PUL FRE FLO
24VDC
Power Supply
Drip
Loop
Drip
Loop
Ensure use of drip
loop for all cables
Use only with GFCI
Protected AC Outlet
Ensure correct voltage power
supply for each component
Use caution when
installing magnets
Ensure pump location
will not spill water from
wave motion
Ensure use of drip
loop for all cables
Safety Instructions & Warnings 1
What’s Included & Installation 2
eFlux Wave Pump Installation 3
Cable Connections 4
Programming Guide 5-9
Safety Warnings & Warranty 10
Thank You!
For purchasing our eFlux Wave Pump Kit.
Please read all instructions before
getting in the LOOP!
eFlux Wave Pump Kit
Safety Instructions & Warnings
Table of Contents
Page 1

Each eFlux Wave Pump Kit includes:
Item Description Quantity
A eFlux DC Wave Pump 1
B Magnet Swivel Bracket Assembly(pre-installed) 1
C 24V DC Transformer, UL® Listed 1
D Wave Pump HUB Controller w/Silicone Cover 1
E Pump HUB Mounting Bracket w/2 Screws 1
F eFlux Wave Pump LED Display 1
G eFlux LED Display Bracket w/2 Screws 1
H eFlux Wave Pump Wireless IR Remote Control 1
J IR Sensor 1
K Micro USB Communications Cable 1
L Cable Wraps 3
M Wave Pump Prefilter 1
P Pump Cable Wrapping 1
!"
or
A
B
C
D
G
P1P3
E
FK
LJ
H
Note:
If your eFlux wave pump is missing
any components, please contact us
directly at www.current-usa.com.
DO NOT RETURN TO RETAILER
Accessory Wave Pumps
#1685 EFlux Wave Pump Manifold HUB
(controls up to 3 wave pumps)
#6004 Accessory Wave Pump, 660 GPH
#6005 Accessory Wave Pump, 1050 GPH
#6006 Accessory Wave Pump, 2100 GPH
#4180 LOOP® Extension Cable, 9 ft./3M
#3239 EFlux Pump 660 Prefiler Pack of 3
#3240 EFlux Pump 1050 Prefiler Pack of 3
#3241 EFlux Pump 2100 Prefiler Pack of 3
#3231 EFlux Pump 660 Impeller
#3232 EFlux Pump 1050 Impeller
#3233 EFlux Pump 2100 Impeller
#3036 24VDC 60w Transformer
P2
LCK P/S SRE SUR PUL FRE FLO
0 1 2
TM
TM
M
P
Replacement Parts
eFlux Wave Pump Kit
Additional Help
What’s Included
For additional installation instructions & videos, please visit our website at www.current-usa.com
Optional Accessories and Replacement Parts
Page 2
STREAM
SURGE
WAVE
LOCK
FEED
P / S
FLOW
FLOW FREQ
FREQ

Installation Instructions
IMPORTANT: Before installation, read ALL SAFETY INSTRUCTIONS & WARNINGS
eFlux Wave Pump Kit
Step 1. Ensure all components are unpacked, unwrap cords and ensure there is no damage.
Step 2. Choose a mounting location inside the aquarium vertical wall for your pump. Clean location
of any dirt, algae or calcium deposits.
Step 3. Install cable wrap wrapping (P) around
wave pump cable. This protects the pump
cable from triggerfish, urchins and other
animals that may damage pump cable. Place
pump prefilter (M) over pump end (optional).
Step 4. Carefully separate magnet (B) from
pump and place pump (A) into position in tank.
Attach pump to tank using magnet. Swivel
and adjust pump as desired.
Magnet
Attachment
Cable Wrap
Pump Prefilter
(optional)
P1P3 P2
INSTALLING WAVE PUMP MANIFOLD HUB AND EFLUX LED DISPLAY
Step 5. Choose a location underneath your aquarium cabinet free of excessive moisture and/or
saltwater creep. Note: if you want the eFlux wave pump LED display outside cabinet, ensure the
mounting location is 6”-10” away from where the wave pump manifold HUB will be mounted.
Step 6. Using included wood mounting screws, mount the eFlux wave pump HUB mounting bracket
(E) and eFlux pump LED display bracket (G) to stand. Slide wave pump manifold HUB (D) and pump
LED display (F) into each bracket.
Step 7. Remove silicone caps from Pump #1 DC input and
Pump #1 connection on manifold HUB. Attach caps to HUB
mounting bracket (E). Keep other silicone caps in place if not
in use.
Step 8. Choose a location for the IR Sensor (J) outside stand. The IR sensor is what receives
control and on-demand command signals from the wireless remote. Unwrap cable and attach the
IR sensor clip to your stand, attach IR sensor cable into the sensor clip. Ensure cable can reach wave
pump manifold HUB (D).
P
M
B
A
D
G
P1P3
E
F
P2
LCK P/S SRE SUR PUL FRE FLO
!"
J
Remove
Cap
Store Cap
Store Cap
LED Display
IR Sensor
Manifold HUB
LED Display
Mounting Bracket
Wood
Screws
Wood
Screws
Wave Pump Manifold
HUB Mounting Bracket
Page 3

AC Power
GFCI Outlet
24VDC
Transformer
eFlux Wave Pump
LED Display
Wave Pump Manifold HUB
P1P3 P2
LCK P/S SRE SUR PUL FRE FLO
!"
IR Sensor
P1P2
P3
Pump #1
Power DC Input
Pump #2
Power DC Input
Pump #3
Power DC Input
Pump #2
Pump Connection
Pump #3
Pump Connection
Port#1
Port#2
Port#3
Port#4
CABLE CONNECTIONS
Important:
Before connecting all of the components together, please review the following specifications in
regards to the Wave Pump Manifold HUB and appropriate connections:
Step 9. Connect cables in the following order:
a. Connect LED Display micro USB cable into Port#2
b. Connect IR Sensor micro USB cable into Port#1
c. Connect eFlux Wave Pump into P1 Pump Connection
d. Connect 24V DC cable into P1 Power DC input
Step 10. Plug 24V DC transformer into GFCI outlet.
LED indicator light on manifold HUB will turn Blue.
Step 11. Use velcro cable wraps (L) for excess cables.
Step 12. Remove clear plastic tab from battery
compartment on wireless remote control (H).
Step 13. Press Main Power Key to
turn pump ON. Pump will operate
in default setting of Stream/Steady
Flow Mode at 100% flow.
Step 14. Follow programming guide
on next page.
Pump #1
Pump Connection
Communication LED
Indicator Light
Specifications:
Pump DC Inputs:
Voltage: 24VDC
Max. DC Input per Channel: 72w@24VDC
Max. DC Output per Channel: 60w@24VDC
Pump Connections:
P1 Pump#1= Main/Primary Wave Pump
P2 Pump#2= Secondary (Gyre) Wave Pump
P3 Pump#3= Steady/Stream Wave Pump**
Note: Pump#3 ONLY operates in steady/stream mode
Micro USB Ports:
Port#1= Communications
Port#2= Wave Pump LED Display Only
Port#3= Communications
Port#4= Communications
Port#1
Port#2
0 1 2
TM
TM
LOCK
Battery Tab
MicroUSB Ports
A
B
C
D
A
B
C
D
Main
Power
eFlux Wave Pump Kit
Installation Instructions
Page 4
STREAM
SURGE
WAVE
FEEDP/S
FLOW
FLOW
FREQ
FREQ

Remote Control Overview
FLOW
FLOW
FREQ
FREQ
Pump LED Display Overview
Main On/Off
Pump 1, Primary Wave Pump
Pump 2, Secondary Wave Pump
Pump 3, Flow/Stream Mode Only
Primary/Secondary Pump
Stream / Steady Flow Mode
Surge / Gyre Mode
Wave / Pulse Mode
Lock/Unlock Key
Increase / Decrease Flow Rate
Increase / Decrease Frequency
FLOW
FREQUENCY
LOCK Mode Main / Secondary Pump
PUMP
Rate Display
Displays which pump is in
programming mode.
Designates if Pump 2 is a Primary
or Secondary (Slave) Pump
LED ON = Secondary Pump (Slave to Pump I)
LED OFF = Primary Pump (Independent)
Displays if the Flow
(velocity) is being shown
on the rate display
Displays level of FLOW or FREQUENCY.
Each LED = 10% FLOW or duration
Displays if the Frequency
(duration) is being shown
on the rate display
1 2 3
TM
TM
LOCK
FEED
WAVE
1
2
3
LOCK
FEED
FEED Mode
Designates if controller and
wireless remote are locked.
LED ON = Locked
LED OFF = Unlocked
Flow Mode
Designates which mode pump is in.
SRE = Stream/Steady
SUR = Surge/Gyre
PUL = Wave/Pulse
SURGE
STREAM P/S
FLOW
FLOW
FREQ
FREQ
P/S
eFlux Wave Pump Kit
Programming Guide
STREAM
SURGE
WAVE
Page 5

Programming Guide
Press the Main ON/OFF key to turn all of the pumps and pump display ON or OFF. When
pumps are on, LEDs on display will illuminate. If all pumps are turned off, all LEDs on display will
be off.
To individually turn each pump ON/OFF, hold the designated Pump Key for 5
seconds. Pump will turn ON or OFF.
To Lock settings and IR remote communication, press Lock
key and hold for 5 seconds, the LED over LCK on the pump
display will turn green.
To unlock settings and IR remote communication, press Lock
key again for 5 seconds, the LED over LCK on the pump
display will turn off. The wireless remote will not operate and
communicate with the HUB and LED display.
To set all pumps into feeding mode, press the FEED Mode key .
All pumps within the LOOP network will go into idle speed for 10 minutes.
After 10 minutes, all pumps will ramp back into their previously programmed
flow mode.
Operational Flow Modes
There are three modes of water flow available for Pumps 1 and 2;Stream/Steady, Surge/Gyre and
Wave/Pulse. Note that Pump 3 is designated as a circulation pump and can only be programmed
in Stream/Steady Flow Mode.
!"#
LOCK
LOCK
LED ON = Locked
LED OFF = Unlocked
FEED
TIME
STREAM/STEADY MODE
0
100%
50%
When a pump is in Stream/Steady mode, the pump will constantly circulate
water at the programmed speed.
Flow
Flow rate is adjustable from
0-100% in 10% increments by
pressing:
FLOW FLOW
Step 1: Turning pumps ON/OFF
Step 2: Turning individual pumps ON/OFF
Step 3: LOCK / unlock remote
Step 4: FEED Mode
Step 5: Programming Flow Modes
eFlux Wave Pump Kit
Page 6
Display remains same
during FEED Mode

Programming Guide
SURGE/GYRE FLOW
FREQ
FREQ 0
100%
50%
FLOW
Press to increase frequency of
pulse (decrease time interval)
Press to decrease frequency of
pulse (increase time interval)
FREQUENCY
10s
FREQUENCY (seconds) 15s 20s 25s 30s 40s 50s 70s 80s 90s
Max. Flow
Frequency (time duration) is adjustable:
WAVE/PULSE MODE
0
100%
50%
FLOW
FREQ
FREQ Press to increase frequency of
pulse (decrease time interval)
Press to decrease frequency of
pulse (increase time interval)
Pump OFF
Pump ON
.3s .5s 1s 2s 3s 4s 5s 6s 7s
.3s .5s .7s
.3s .5s .7s 1s
1s
2s
2s
3s 4s 5s 6s 7s
3s 4s 5s 6s 7s
.7s
TIME
ON
Frequency (time duration) is adjustable:
FLOW
FLOW
Flow rate is adjustable
from 0-100% in 10%
increments by pressing
FLOW keys on wireless
remote.
FREQUENCY (seconds)
OFF
Max. FLOW
ON
OFF
When a pump is in Surge/Gyre mode, the pump will gently ramp up and down
to the maximum flow speed based on the frequency (time) programmed. This
mode mimics back and forth water surges found in the ocean. See GYRE for
using 2 pumps and creating Gyre flow.
When a pump is in Wave/Pulse mode, the pump will turn on/off, creating a
pulsing between the maximum flow and off. This flow simulates waves
commonly found on reef crests.
FLOW
FLOW
Flow rate is adjustable
from 0-100% in 10%
increments by pressing
FLOW keys on wireless
remote.
Choosing flow modes
Every aquarium is different and eFlux wave pumps provide multiple modes of flow for a wide variety
of applications.
STREAM/STEADY MODE
SURGE/GYRE MODE
WAVE/PULSE MODE
eFlux Wave Pump Kit
Steady, constant flow stream (adjustable) Alternates a slow ramp up/down Alternates a short pulsing action
Mimics strong, flowing water currents Mimics surging water currents Mimics wave type action
Adjustable flow speed only, 0-100% Flow 0-100%, frequency 10-90 sec. Flow 0-100%, frequency 0.3-7 sec.
Excellent circulation in specific areas Ideal for soft corals and anemones Ideal for SPS corals
Page 7

Programming Guide
Step 5A: Designate pump to program (1, 2, or 3)
Press the pump you pick to program by
pressing the designated pump key on the
wireless remote.
Pump icon will illuminate on LED display.
Step 5B: Designate water flow mode
Press the FLOW mode you wish to run the pump
in by pressing the designated flow key on wireless
remote.
Flow icon will illuminate on the LED display.
Step 5C: Program the maximum FLOW
Press the increase/decrease FLOW keys to adjust
the pumps maximum flow rate until you have reached
the desired flow. FLO will illuminate on the LED display.
The RATE display will show the flow from 0-100% in
10% flow increments on LED display.
Step 5D: Designate FREQUENCY setting
If programming the pump in either SURGE or WAVE
mode, adjust the FREQUENCY setting by pressing
the increase/decrease FREQ keys on wireless remote
until the desired frequency/duration is reach.
The RATE display will show the
FREQUENCY in 10 settings
as follows:
Note: Decreasing FREQUENCY increases the time duration between min/max flow.It will appear
opposite in your aquarium (lowering frequency/duration will increase wave motion).
Your setting will automatically be saved into memory.
No additional keys need to be set to save your settings.
!"#
FLOW
FLOW
STREAM
SURGE
WAVE
FREQ
FREQ
10s 15s 20s 25s 30s 40s 50s 70s 80s 90s
Pump OFF
Pump ON
.3s .5s 1s 2s 3s 4s 5s 6s 7s
.3s .5s .7s
.3s .5s .7s 1s
1s
2s
2s
3s 4s 5s 6s 7s
3s 4s 5s 6s 7s
.7s
Wave/Pulse
Frequency Setting
SURGE/GYRE
Frequency Setting
eFlux Wave Pump Kit
Page 8

Programming Guide
Primary/Secondary Pump Syncing (GYRE)
A pump group consists of one Primary pump and at least one Secondary pump. The eFlux Wave
Pump manifold HUB automatically designates Pump 1 as a Primary pump. Pump 2 can
be designated as a Primary pump (controlled independently), or as a Secondary pump (runs oppo-
site of Primary pump). Running two pumps in tandem (Primary/Secondary) automatically synchro-
nizes the pumps in opposite flow modes (WAVE or SURGE), providing stronger wave flow and/or
gyre flow in your aquarium. Note: Primary/Secondary mode is not available using Stream Mode.
To sync your pumps as Primary/Secondary (GYRE Flow):
Step 1: Program Pump 1 into desired mode
Press PUMP 1 keyon wireless remote, pump 1 LED will illuminate
on the LED display.
Press WAVE or SURGE mode, mode LED will illuminate
on the LED display.
Adjust both FLOW (Flow) and FRE (Frequency) to the
desired amount using increase/decrease arrow keys.
Step 2: Program Pump 2 as Secondary Pump
Press PUMP 2 key on wireless remote, pump
2 LED will illuminate on LED display.
Press the P/S key on the wireless remote.
P/S will illuminate on the LED display when Pump 2 is
designated as a Secondary pump.
Pumps will now operate in Sync.
Step 3: Program Pump 2 as Primary Pump (Independent)
Press PUMP 2 key on wireless remote, pump 2
LED will illuminate on LED display.
Press the P/S key on the wireless remote.
P/S LED will turn off on LED display when Pump 2 is
designated as a Primary pump.
Pump can now be programmed independently of Pump 1.
NOTE: PUMP 3 is ONLY a Primary Pump (independent) and ONLY in Steady/Stream Mode.
!
"
"
FLOW
FLOW
FREQ
FREQ
SURGE WAVE
eFlux Wave Pump Kit
P/S
P/S
Page 9

GFCI Outlet
Drip Loop
P1P3 P2
Drip
Loop
DC
Do not install pumps where strong currents can harm animals. Do
not install close to sand bed where it can suck/stir sand.
Pumps can produce powerful wave action in both wave and surge
modes. Ensure your aquarium is designed for wave pumps and
ensure pumps are mounted low enough not to push water out of
the aquarium tank.
Magnet assembly is VERY powerful. Be cautious not to cause
injury to fingers.
Keep magnets and all accessories out of reach of children.
Never place magnets or pump near sensitive electronics, sharp
objects or other attractive surfaces.
Do not run pumps dry or out of water.
Always place spacer between magnets when not in use.
Always unplug with dry hands for maintenance or servicing.
Turn all controllers OFF and disconnect power supply before
performing any service or maintenance.
This product MUST be powered by a UL or ETL listed power supply.
To avoid possible electric shock, power supply MUST be plugged
into a GFCI wall outlet installed by a certified electrician in
accordance with all local codes. All products must have a drip loop.
eFlux Wave Pump Kit
This product MUST be purchased from an authorized Current-USA
reseller. Visit our website for a list of unauthorized resellers.
Current USA, Inc. warrants this product against defects in
materials and worksmanship for ONE (1) YEAR from the date of
original retail purchase and is none transferable.
Current-USA One Year Limited Warranty
Safety Warnings and Warranty
Page 10
Other manuals for eFlux
2
Table of contents
Other Current Water Pump manuals
Popular Water Pump manuals by other brands

Linkam Scientific Instruments
Linkam Scientific Instruments ECP user guide

Calpeda
Calpeda CT Series operating instructions

Binder
Binder VAP 1 operating manual

Barracuda PUMPS
Barracuda PUMPS BAAU33 owner's manual

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS 60 Series Installation, operation, and maintenance manual with parts list

SMC Networks
SMC Networks PB1313A Operation manual