manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Control Unit
  8. •
  9. CyberData V3 Keypad Manual

CyberData V3 Keypad Manual

Other manuals for V3 Keypad

3

This manual suits for next models

1

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The IP Endpoint Company
Installation Quick Reference
VoIP V3 Zone Controller:
4-Port Audio Out
SIP Compliant
011171
Quick Reference 930445E © 2014 CyberData Corporation ALL RIGHTS RESERVED© 2014 CyberData Corporation ALL RIGHTS RESERVED 930445E Quick Reference
Mounting
Contacting CyberData
To mount the V3 Zone Controller:
1. On the mounting location, mark and then drill two 3/16-inch (0.1875-inch) holes 3.5 inches apart from and
parallel to each other for the plastic-ribbed anchors and screws. See the drawing below.
2. Insert the plastic-ribbed anchors into the prepared holes.
3. Install the #6 screws into the plastic-ribbed anchors and leave approximately 1/8-inch gap from the screw head
to the wall.
4. Determine which sides of the V3 Zone Controller will be facing up, and then slide the V3 Zone Controller down
over the screws to latch onto the screws.
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Web: http://www.cyberdata.net/support/contactsupportvoip.php
RMA Dept: (831) 373-2601 ext. 136
Email: [email protected]
RMA Status: http://www.cyberdata.net/support/rmastatus.html
Warranty and RMA information is available at the following website:
http://www.cyberdata.net/support/warranty/index.html
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
www.CyberData.net
The VoIP V3 Zone Controller with Audio-Out enables access to existing paging speakers through a VoIP phone system.
The interface is designed to use a standard paging amplifier with audio inputs and supports paging up to 15 zone groups
from a VoIP phone.
Getting Started
• Be sure that you have received all the parts described in the Parts List section.
• Download the VoIP V3 Zone Controller Operations Guide from the following website address:
http://www.cyberdata.net/products/voip/legacyanalog/pagingzonev3/docs.html
Parts List
Product Specifications
Regulatory Compliance FCC Class A, UL 60950, CE
Power Requirement PoE or +48VDC
LAN Speed 10/100 Mbps
Protocol SIP compliant
Part Number 011171
Dimensions 6.11”L x 4.05”W x 1.15” H
Weight 1.2 lbs.
(2) #6 Plastic-Ribbed Anchors (2) #6 x 1 1/2-inch Screws
(1) Mounting Kit
(1) VoIP Zone Controller - 4-Port Audio Out
© 2014 CyberData Corporation ALL RIGHTS RESERVED 930445E Quick Reference Quick Reference 930445E © 2014 CyberData Corporation ALL RIGHTS RESERVED
Verifying Operations and Settings
To restore the V3 Zone Controller’s factory default
settings:
1. Use a paper clip to press and hold the RTFM
switch while all of the indicator LEDs turn off.
See the picture on the right.
2. Continue to press the RTFM switch until after
the indicator LEDs turn back on.
3. Release the RTFM switch. All of the V3 Zone
Controller settings will be restored to the
factory default settings.
4. You will hear the "Restoring defaults..." audio
message play through all ports before the
device reboots.
Front View with LEDs
Back View with RTFM Switch
Status
(GREEN LED)
Power Status
(BLUE LED)
Link
(YELLOW LED)
Activity
(GREEN LED)
The round, BLUE Power Status LED on the front of the V3 Zone Controller comes on indicating that the
power is on.
The square, YELLOW Link LED above the Ethernet port indicates that the network connection has been
established. The Link LED changes color to confirm the auto-negotiated connection speed:
• This LED is YELLOW at 10 Mbps.
• This LED is ORANGE at 100 Mbps.
The square, GREEN Activity LED above the Ethernet port blinks when there is network activity.
The round, GREEN Status LED comes on after the device is booted and initialized. This LED blinks when
the unit is operational.
The square, GREEN Audio Activity LEDs turn on solid when a Zone is being paged.
Paper clip RTFM switch
Audio Activity
(GREEN LED)
Typical Zone Controller Setup Using the V3 Zone Controller
Setting Up the VoIP V3 Zone Controller
Generic PoE Switch
12 34 56
IP Phone
IP PBX Server
VoIP V3 Zone Controller 4-Port Audio Out
Analog Amplifiers Paging Speakers
Non PoE (with 48 VDC power supply)
Chassis Ground
Chassis Ground
PoE
To set up the V3 Zone Controller, connect the
device to your network:
Poe
•ForPoE, plug one end of an 802.3af Ethernet
cable into the V3 Zone Controller Ethernet port.
Plug the other end of the Ethernet cable into
your network. See the figure on the left.
Non-Poe
•ForNon-PoE, connect the V3 Zone Controller
to a 48VDC power supply. See the figure on
the left.
Chassis Ground
• If required, connect the earth grounding wire to
the Chassis Ground. See the figure on the
left.