D-MAX DRX-500 User manual

CCTV RECEIVER
USER MANUAL
DRX-500
DONGYANG UNITECH

2
WARNING
Always have the unit installed by the store it was purchased from.
zImproper connections and/or installation could result in electrical shock, fire or
other serious injury or damage.
Do not place the unit on an unstable surface.
zAlways checks the strength and stability of the installation location.
zA falling unit will result in damage and could cause serious injury.
Never disassemble or attempt to repair or modify the unit.
zDisassemble by untrained personnel could result in serious electrical shock, fire
and/or malfunction.
Never use in locations where combustible materials are used.
zThe unit should never be used where combustible materials, such as gases, are
being used.
zFire, explosion or other serious accidents could occur
Never touch electrical connections with wet hands.
zTouching electrical connections with wet hands could result in serious electrical
shock.
Never expose the unit to water.
zIf the unit becomes wet, turn off the power and unplug it immediately.
zStop using the unit if it becomes wet and contact your nearest supplier or
manufacturer representative.
Never use the unit if there is an abnormality.
zTurn off the power and unplug the unit immediately if there is any type of
abnormality, such as a strange smell or smoke.
zContinuing to use a unit that is not operation properly could result in serious injury
or damage to the unit.
Always use the designated power supply.
zFailure to use the proper power supply could result in fire, electrical shock, serious
injury and/or damage.
zAlways uses the designated power supply.
Always handle the connecting cords properly.
zNever damage or modify the connecting cords.
zNever pull on the connecting cord, expose them to extreme heat and/or place
heavy objects on top of them.
zFailure to follow these warnings could result in fire, electrical shock or other
damage or injury.

3
CAUTION
Always use the unit indoors.
zThe unit should never be used outdoors, or in any place where it will be exposed to
rain or other extremes of moisture.
zDirect exposure to water will result in rust and will damage the unit.
Never use in environments that have heavy concentrations of dust, smoke, steam or
humidity.
zEnvironments such as these could result in fire, electrical shock or other serious
damage or injury.
Never place the unit in extremes of high or low temperatures.
zExtreme temperatures will damage the unit.
zAlways use within an operating range of -15℃to 60℃
Never place the unit near the magnetic.
zThe unit should never be placed near by magnetic.
zIt is reason for the malfunctions.
Never expose the unit to impact.
zStrong impact may seriously damage the unit.
FOR PROPER OPERATION
Never install the unit yourself.
zThe unit should be installed by trained personnel.
This product has been designed and manufactured in accordance with the harmonized European
standards, following the provisions of the below stated directives.
Low Voltage Directive 73/23/EEC & Electromagnetic Compatibility Directive
89/336/EEC(EN60065, EN50130-4, EN55022, EN61000-4-2, 3, 4, 5, 6, 11)
This devise complies with part 15 of the fcc rules operation is subject to the following two conditions: (1)
This device may not cause harmful interference and (2) This device must accept any interference received
including interference that may cause undesired operation

4
Table of Content
CHAPTER1. INTRODUCTION 4
1. FEATURES 4
CHAPTER2. CONNECTIONS
1. NAMES AND FUNCTIONS OF EACH PART 5
2. HOW TO CONNECT TO PERIPHERALS 7
CHAPTER3. HOW TO USE THE DETAILED FUNCTIONS 8
1. RS485 CONNECTION 8
2. RS422 CONNECTION 9
3. ADDRESS SETTING 10
CHAPTER4. NOTICE 11
1. CAUTION 11
2. REPAIRING MEASURES 12
CHAPTER5. APPEARANCE 13
CHAPTER6. SPECIFICATION 14

5
CHAPTER1. INTRODUCTION
1. FEATURES
1-1. Controlling through Data Communication
Data communication with the controller allows this receiver to control Pan/Tilt, Zoom
Lens, Camera, Light Power, etc.
1-2. Supports Various Communicating Standards.
This receiver covers various communicating methods of RS485, RS422, TTL.
1-3. Waterproof, Dustproof
Designed to be protected from water and dust, this machine can be used both indoor
and outdoor.
1-4. PAN/TILT Control
Can control Pan/Tilt Driver.
1-5. ZOOM LENS Control
Can control Zoom Lens.
1-6. AUTO PAN Function
Auto Pan (On/Off)
1-7. Choice of Voltages for PAN/TILT Controlling
Can select the kind of voltages for controlling Pan/Tilt Driver among AC24V, AC110V and
AC220V.

6
CHAPTER2. CONNECTIONS
1. NAMES AND FUNCTIONS OF EACH PART
LEFT
SW
POWER
INPUT
POWER
POWER
ELIGHT UP
CAMERA DOWN
DATA
RXD
PAN/TILT
A/PANRIGHT
COM
ZOOMP/T FOCUS COMCOM TXD
ON
110V
220V
PT POWER SEL
AC24VINPUT COM
24V0V 220V110V
14V
3
DIP SW
AC IN
14V
OV
OLD
8
7
6
5
4
ADDRESS
ON
1
2
ADDRESS/INITIAL SW
ODR
LENS
TTL
RS422/485
DATA INPUT
485(+)
485(-)
422(+) OUT
422(-) OUT
GND
422 IN
522 IN
ON
485/422 SEL
ER
ACAC
13
2
4
5
9
7
6
11
10
ZOOM LENS
LPC 8
①MAIN POWER Switch
Operates On/Off of Power Supply.
②MAIN FUSE
Protects the Whole Machine against Surge. Uses 5A FUSE.
③1A FUSE
Cut off the electric currency in case the unexpected accidents happen on the Electric
Circuit or on Pan/Tilt Driver.

7
④AC110/220 Converting Switch
Choose suitable kind of Power Sources with this switch.
⑤P/T POWER SELECT
Can choose suitable kind of Pan/Tilt-activating power. AC110V, AC220V and AC24V are
available.
⑥TTL/485(422) SELECT
Insert the socket to the pin on your demand. If your socket covers the pin beside which
'RS422/485' is written, you choose 485/422 way
⑦DATA INPUT
This is an Outlet Box to which Data Lines would be connected when you use RS-422 or
RS-485.
⑧LPC (LENS POWER CHANGE)
If Zoom Lens operates its zooming In/Out work oppositely, turn the socket over.
⑨DIP Switch
Sets each receiver (camera)'s address with this switch. (You must turn off the switches
of 9 and 10 if you use 'DCK-255' controller together. If you turn on the switches of 9 and
10, you can use this receiver for DVR Use.)
⑩TTL Data Input
It is data communication terminals for compatibility with old models. These terminals will
be activated if the socket in COMM SEL box covers the pin named 'TTL'.
⑪End Resistance Switch (ER)
Notice: Only in the last receiver among the all connected, this switch is to be 'ON'
position.

8
2. HOW TO CONNECT TO PERIPHERALS
□Basic Diagram of Line Connection
Notice: When released, this Unit's Main Power is set to AC220V and Pan/Tilt Voltage is
set to AC24V. Please plug after confirming your power source.
CAMERA POWER
UP
DOWN
LEFT
P/T COMMON
AUTO PAN
RIGHT
IRIS
FOCUS
ZOOM
LENS COMMON
MAIN POWER
AC 220V
E
LIGHT POWER
AC IN
A/PAN
ON
POWER
INPUT
AC ACE
SW
POWER
CAMERALIGHT
POWER PAN/TILT
UP DOWN LEFT RIGHT
24V
110V
220V
0V
PT POWER SEL
110V 220V
INPUT AC24V COM
OV
14V
14V
485(-)
COMM SEL
TXD
LENS
ZOOM LE NS
COM
DATA
FOCUSP/T ZOOM COMCOM RXD
ON
ER
TTL
RS422/485
522 IN
GND
422(-) OUT
422(+) OUT
DATA INPUT
LPC
DIP SW
7
8
TTL
ODR
ADDRESS
3
6
5
4
2
ON
1
422 IN
485(+)
ADDRESS/INITIAL SW

9
CHAPTER3. HOW TO USE THE DETAILED
FUNCTIONS
1. RS485 CONNECTION
Used when the RS485 mode is chosen in the Junction Box. Shielded Twist Paired Cable is
recommended. In case of using AWG28 cable, this receiver can send the data up to
1.2Km away. (It may differ from real spots)
In COMM SEL box, you must cover the Pin on which 'RS422/485' is written with the
socket.
Notice: There are 2 sets of Camera Control Ports in the Keyboard Controller (DCK-255),
and each of them can be connected to up to 128 receivers in parallel.
KEYBOARD JUNCTION BOX
-
-
OUT
422
485
CAMERA CONTROL 2CAMERA CONTROL 1
+ - C
422
OUT
-
422
+
OUT
422
IN
+
485485 N
G C +
N
D
422
IN
-
422
OUT
+
N 485
IN
422
SUB KEYBOARD
G
D
N
C C
422
+
IN
422
IN
-
N N
C - +
OUT
422422
OUT
+ - +
485485 N
RTS
GRX C
D
N
422
-
IN RTS
N
접지SK
DOWN
POWER
LIGHT
POWER
INPUT
EAC AC CA MERA UP
ON
POWER
SW
110V
220V
LENS
COM
COM
P/T
PAN/TILT
RIGHTLEFT A/PAN
ZOOM LENS
ZOOM FOCUS
DATA
RXDCOM TXD
422(+) OUT
422(-) OUT
COMM SEL
485(-)
END LINE
ON
GND
522 IN
RS422/485
TTL
DATA INPUT
485(+)
422 IN
RS422/485 위치 로
DATA INPUT
GND
COMM SEL
422(-) OUT
422(+) OUT
Place the Socket Like
ON
END LINE
422 IN
485(+)
TTL
RS422/485
522 IN
485(-)
this Position

10
2. RS422 CONNECTION
Used when the RS422 mode is chosen in the Junction Box. Shielded Twist Paired Cable is
recommended. In Case of using AWG28 Cable, this receiver can send the data up to
1.2Km away. (It may differs from real spots)
In COMM SEL box, you must cover the Pin on which 'RS422/485' is written with the
socket.
CAMERA CONTROL 2
422
IN
N
KEYBOARD JUNCTION BOX
CAMERA CONTROL 1
C
422
N
+ - C
422
OUT
-
422
+
OUT
422
IN
+
485485 N
-
-
OUT
422
485
G +
N
D
IN
-
422
OUT
+
485
C
+
RTS
SK
422
SUB KEYBOARD
G
D
N
C
422
IN
-
N
- +
OUT
422422
OUT
+ -
485485
IN
C
+
N
GRX C
D
N
422
-
IN RTS
N
접지
220V
110V
POWER
AC E
INPUT
SW
POWER
ON
POWER
AC LIGHT UP
CAMERA LEFT RIGHT
PAN/TILT
DOWN A/PAN P/T
COM
DATA INPUT
GND
COMM SEL
422(-) OUT
422(+) OUT
FOCUSZOOM
ZOOM LENS
COM
LENS
TXDCOM RXD
DATA
RS422/485 위치로
ON
END LINE
422 IN
485(+)
TTL
RS422/485
522 IN
485(-)
DATA INPUT
GND
COMM SEL
422(-) OUT
422(+) OUT
Place the Socket Like
ON
END LINE
422 IN
485(+)
TTL
RS422/485
522 IN
485(-)
this Position

11
3. ADDRESS SETTING
1. Set the addresses with DIP switches numbered 1~8. You can use up to 255 receivers
(cameras) with the keyboard controller (DCK-255).
2. You must turn off the switches of No. 9 and 10 if you are using the 'DCK-255'
controller together.
3. If you turn on the switches of 9 and 10, you can use this receiver for DVR use.
*Table for Address Setting
DIP SWITCHES (HEX) DIP SWITCHES (HEX)
RX NO
(DEC) 1 2 3 4 5 6 7
RX NO
(DEC) 1 2 3 4 5 6 7
1 ON OFF OFF OFF OFF OFF OFF 33 ON OFF OFF OFF OFF ON OFF
2 OFF ON OFF OFF OFF OFF OFF 34 OFF ON OFF OFF OFF ON OFF
3 ON ON OFF OFF OFF OFF OFF 35 ON ON OFF OFF OFF ON OFF
4 OFF OFF ON OFF OFF OFF OFF 36 OFF OFF ON OFF OFF ON OFF
5 ON OFF ON OFF OFF OFF OFF 37 ON OFF ON OFF OFF ON OFF
6 OFF ON ON OFF OFF OFF OFF 38 OFF ON ON OFF OFF ON OFF
7 ON ON ON OFF OFF OFF OFF 39 ON ON ON OFF OFF ON OFF
8 OFF OFF OFF ON OFF OFF OFF 40 OFF OFF OFF ON OFF ON OFF
9 ON OFF OFF ON OFF OFF OFF 41 ON OFF OFF ON OFF ON OFF
10 OFF ON OFF ON OFF OFF OFF 42 OFF ON OFF ON OFF ON OFF
11 ON ON OFF ON OFF OFF OFF 43 ON ON OFF ON OFF ON OFF
12 OFF OFF ON ON OFF OFF OFF 44 OFF OFF ON ON OFF ON OFF
13 ON OFF ON ON OFF OFF OFF 45 ON OFF ON ON OFF ON OFF
14 OFF ON ON ON OFF OFF OFF 46 OFF ON ON ON OFF ON OFF
15 ON ON ON ON OFF OFF OFF 47 ON ON ON ON OFF ON OFF
16 OFF OFF OFF OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF
17 ON OFF OFF OFF ON OFF OFF 49 ON OFF OFF OFF ON ON OFF
18 OFF ON OFF OFF ON OFF OFF 50 OFF ON OFF OFF ON ON OFF
19 ON ON OFF OFF ON OFF OFF 51 ON ON OFF OFF ON ON OFF
20 OFF OFF ON OFF ON OFF OFF 52 OFF OFF ON OFF ON ON OFF
21 ON OFF ON OFF ON OFF OFF 53 ON OFF ON OFF ON ON OFF
22 OFF ON ON OFF ON OFF OFF 54 OFF ON ON OFF ON ON OFF
23 ON ON ON OFF ON OFF OFF 55 ON ON ON OFF ON ON OFF
24 OFF OFF OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF
25 ON OFF OFF ON ON OFF OFF 57 ON OFF OFF ON ON ON OFF
26 OFF ON OFF ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF
27 ON ON OFF ON ON OFF OFF 59 ON ON OFF ON ON ON OFF
28 OFF OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF
29 ON OFF ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF
30 OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF
31 ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF
32 OFF OFF OFF OFF OFF ON OFF 64 OFF OFF OFF OFF OFF OFF ON

12
* If you turn on NO.7 DIP S/W, NO.1 in above Table will be NO.65 and NO.64 in above
table will be set for NO.128. And if you turn off NO.7 DIP S/W and turn on NO.8 DIP S/W,
NO.1 in above Table will be NO.129. And if you turn on both NO. 7 and 8 DIP switches,
NO.1 in above Table will be the NO.193.
In this way, you can set up to 255 addresses.
CHAPTER4. NOTICE
1. CAUTION
□You make sure that the Power Switch is Off Position before install.
□Never install in improper circumstances. (Consider Temperature, Humidity, etc)
□Never install near the Magnet or so.
□Never open the Cap in Operation.
□Always use the designated power supply.
□This unit can be used in -15℃∼60℃Condition and also be used both indoor and
outdoor.
□Never expose the unit to impact.
□Always handle the connecting cords properly.

13
2. REPAIRING MEASURES
* Check the unit as the following ways when you happen to meet situations mentioned in
table.
Status Confirmation Management
Power not supplied Is the Power supplied
normally? Reconnect the Power after
confirmation
Power is being supplied
normally, but the unit doesn't
work
Is the right fuse and voltage
you are using? Check the fuse and control the input
voltage of S/W in normal
Data LED is not working Is Data Line connected
normally? Check the state of Data Line
Connection
Operates up & down, but
doesn't operate left & right Isn't the unit being fixed in
AUTO PAN function? Off the AUTO PAN function
Data LED is operating, but the
Pan/Tilt doesn't work
(1) Is the address of DIP
S/W correct?
(2) Is the socket in right
position in COMM SEL box?
1) Off the power and fix a correct
DIP Switch
(2) Check again the socket's position
in COMM SEL box
There's a trouble at a
revolution speed of PAN/TILT Is the right voltage selected? In the Pan/Tilt power selecting box,
confirm the right connection
Zooming is operating in
opposite way Insert the socket oppositely in LPC
box
Doesn't operate left & right Is the unit in AUTO PAN
function? Off the Auto Pan function at
Keyboard
*Please contact where you purchased if you happen to meet the other problems.

14
CHAPTER5. APPEARANCE
UNIT: mm
제6장 제품 규격
280
260
280
130
260

15
CHAPTER6. SPECIFICATION
Power ●AC 110V/220V, 50/60HZ
Power Consumption ●1KW
●RS485/RS422 DATA
As
y
nc.
,
1 start bit
,
1 sto
p
bit
,
8 data bits
,
No
p
arit
y,
9600 b
p
s
Communicating Method ●NEGATIVE TTL (9V PULL UP)
As
y
nc.
,
1 start bit
,
1 sto
p
bit
,
8 data bits
,
Even
p
arit
y,
1200 b
p
s
Cable ●Shielded Twisted Pair Cable is recommended
Address Setting ●DIP Switch
●ZOOM --- ±9V
●FOCUS --- ±9V
●IRIS --- ±9V
*Can change the lens-activating voltage in control keyboard.
●PAN/TILT --- AC 24V, Input Power (AC110, 220V)
●CAMERA POWER --- Same as Input Power (MAX. 1A)
●AUTO PAN --- Same as Pan/Tilt Power
●LIGHT POWER --- Same as Input Power (MAX 5A)
*When released, Pan/Tilt Power is set to AC24V.
Voltages
●AUX1 --- No Voltage, Point of Contact
Constituent Parts
●CCTV Receiver 1EA
●Manual 1EA
●Fuse (1A, 5A) 2EA
●Brackets 4EA
Dimension ●W: 280 ×H: 280 ×D: 130 (UNIT: mm)
Weight ●3Kg
Material ●PC . ABS (Grey)
Notice: Some gages can be modified without notice for improving the efficiency and
quality of the unit.

Table of contents