DADISICK QT Series User manual

USER'S MANUAL
Thank you ve much for purchasing DADISICK products!
Please be familiar with the user manual and product manual before use.
For your safety, please be sure to follow the precautions in the safety precautions.
Please be sure to follow the instructions, product manual, DADISICK website, and other precautions.
Please keep it properly for easy retrieval.
The specications and external dimensions recorded in this manual are subject to change or discontinuation
due to product improvements without prior notice.
Please conrm the latest information on the DADISICK website.
Figure can va
QT series
SAFETY LIGHT CURTAIN SENSOR
Emitter and Receiver
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD
Website: Email:
www.dadisick.com sale@dadisick.com
We resee the right to make technical changes
2023-04-11
GB/T 19001-2016

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 02
Website: Email:
www.dadisick.com sale@dadisick.com
Warning Failure to follow instructions may result in serious injury or death.
01. Fail-safe device must be installed when using the unit with machinery that may cause serious inju or substantial economic loss. (e.g. nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal inju, economic loss or re.
02. Do not use the unit in the place where ammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or re.
03. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
04. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
05. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
01. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
02. Use a d cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re.
03. Do not use a load over the range of rated relay specication.
Failure to follow this instruction may result in re, relay broken, contact melt, insulation failure or contact failure.
•
Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
•
12 - 24 VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
•
Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor rst.
•
When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0 V and F.G.
terminal to remove noise.
•
When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
•
Wire as sho as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
•
This unit may be used in the following environments.
- Indoors (in the environment condition rated in 'Specications')
- Altitude max. 2,000 m
- Pollution degree 2
- Installation catego II
Caution Failure to follow instructions may result in inju or product damage.
CAUTIONS DURING USE
Warning Failure to follow instructions may result in serious injury or death.
01. Fail-safe device must be installed when using the unit with machinery that may cause serious inju or substantial economic loss. (e.g. nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal inju, economic loss or re.
02. Do not use the unit in the place where ammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or re.
03. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
04. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
05. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
• Symbol indicates caution due to special circumstances in which hazards may occur.
SAFETY CONSIDERATIONS

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 03
Website: Email:
www.dadisick.com sale@dadisick.com
Operation and display
Emitter Receiver
Status indicator Status indicator
Emitter
Receiver
Red, always on
Green
Red
Lights flashing
Normal operation of light curtain LED Indicator status Explain
Turns on the power
All light paths are connected
Light path shading
Receiver and emitter are red Receiver and Emitter are not aligned
Interference or overstep detection range

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 04
Website: Email:
www.dadisick.com sale@dadisick.com
Dimensioned drawings
Remarks:
L=18+P+H+J+18 H n 1 K
H:Height of protected areaL Total length of light screen
n Beams number
K Resolution ratio
Height of protection
Beams number
Emitter Receiver
(10mm)
1. QT signal output selection (actual output of transistor working normally)
load
load
BLUE (0V)
BROWN (VCC)
WHITE (OSSD1)
GREEN (OSSD2)
BLACK (CP)
RED (CE)
load
load
BLUE (GND)
BROWN (VCC)
WHITE (OSSD1)
GREEN (OSSD2)
BLACK (CP)
RED (CE)
load
BLUE (GND)
BROWN (VCC)
WHITE (OSSD1)
GREEN (OSSD2)
BLACK (CP)
RED (CE)
load
load
BLUE (0V)
BROWN (VCC)
WHITE (OSSD1)
GREEN (OSSD2)
BLACK (CP)
RED (CE)
load
A B
CD
+24V
0V
+24V
0V
K(m m)
P(m m)
J(m m)
10
5
20 40 8 0 2 0 0
30
10 15 20 40
32 25 25 25 25 25
20

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 05
Website: Email:
www.dadisick.com sale@dadisick.com
3. PNP output wiring diagram
2. NPN output wiring diagram
This figure is an example of NPN double output 7-pin wiring.
NPN
Relay
load
load
butt-joint
Ground wire
(Shield net)
Yellow Green
(+12~24V DC)
0V+
-
Power
2
3
4
5
6
7
1 234567
1
BLUE (0V)
BROWN (VCC)
WHITE (0V OUT1)
GREEN (0V OUT2)
BLACK (CP)
RED (CE)
WHITE (0V OSSD1)
GREEN (0V OSSD2)
butt-joint
+12~24V DC
Emitter Receiver
This figure is an example of PNP double output 7-pin wiring.
Relay
load
load
butt-joint
Ground wire
(Shield net)
Yellow Green
(+12~24V DC)
0V+
-
Power
2
3
4
5
6
7
1 234567
1
BLUE (0V)
BROWN (VCC)
WHITE (0V OUT1)
GREEN (0V OUT2)
BLACK (CP)
RED (CE)
WHITE (0V OSSD1)
GREEN (0V OSSD2)
butt-joint
+12~24V DC
PNP
Emitter Receiver

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 06
Website: Email:
www.dadisick.com sale@dadisick.com
4. Selection of safety light curtain controller
4.1 Wiring diagram of QET built-in controller
RED(CE)
WHITE(24V OSSD1)
GREEN(24V OSSD2)
RED(CE)
GREEN(24V OSSD2)
WHITE(24V OSSD1)
ON
OFF
Power Supply
Protection
ON OFF
A group of NO, a group of NC
Output:
Power input:
Model:
Power consumption:
Contact rating:
Built in controller of safety light curtain
(simple type)
AC250V 5A
≤5W
AC220V/110V50/60HZ
QET
Bypassed
OSSD2
OSSD1
Light
Shading
Power ON
BLUE WHITEBLACK
BROWN
BLACK BLUE YELLOW
GREEN
BROWN
GREEN REDRED
GROUND WIRE
GROUND WIRE
OS1 OS2 VCC OS1OS2
VCC
GREEN WHITE
Emitter Receiver
NameOrder separately Model
Safety relay QSRN
QSRN safety relays have three groups of NO and one group of NC,
with strong control capabilities. They are suitable for various signal
monitoring in industrial places with high safety requirements,
including emergency stop signals, safety door opening and closing
signals, safety light curtain signals, and two-handed button signals.
Built-in
controller QET Used to monitor the signal processing of QT series light curtain, and
output one group of NO and one group of NC.
Light curtain
relay QET-1 Output conversion between NC and NO for QT series light curtain.
Safety relay Ter-A
Equipped with a mode switch, it can be used for most safety
components, such as light curtains, safety switches, carpet contacts,
two handed switches, etc.Automatic/manual reset paddles for quick
configuration.Dual channel monitoring circuit, safe and reliable.
Multifunctional
switching switch
Descriptions

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 07
Website: Email:
www.dadisick.com sale@dadisick.com
4.2 Wiring diagram of QSRN safety relay
4.3 Wiring diagram of Ter-A safety relay
Dual channel light cuain PNP switch safety input, with automatic reset and PLC signal output.
Emitter
Blue
Brown
0V
24V
NC
CP
CE
shielded wire
White
Green
Black
Red
YG
CE
Red
CP
Black
OSSD 1White
OSSD 2
Green
Brown 24V
Blue 0V
shielded wire
YG
Receiver
NC
23 13 33 43
S2 S1 0V 24V
24 14 34 44
SRC SR 0V 24V
24V
0V POWER
SUPPLY
Emitter
Receiver
24V
0V
POWER
SUPPLY
Blue 0V
NC
CP
CE
shielded wire
White
Green
Black
Red
YG
CE
Red
CP
Black
OSSD 2
White OSSD 1
Green
shielded wire
YG
NC
A1
A2
X1
T1 R1 T2 R2
Y1
14 24 34 42
13 23 33 41
A
M1 2 3
ON ON ON
Brown 24V
PLC signal
Ter-A
Brown 24V
Blue 0V

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 08
Website: Email:
www.dadisick.com sale@dadisick.com
87
65
4 3
21
+
-
Light curtain input
NC
NO
Share
Power input
When not powered on
87
65
4 3
21
+
-
Light curtain input
NC
NO
Power input
When powered on
4.4 Wiring diagram of QET-1 light curtain relay
Share
+
-
87
2
4
6
1
3
5
Circuit diagram
4.5 Wiring between light curtain and PLC and one-chip computer system
NPN wiring:PNP wiring:
PLC
+24V DC
-0V
NPN
0V
0V
Brown
Emitter Receiver
Brown
Blue Blue
White
Green
PNP
+24V
+24V
Emitter Receiver
Brown Brown
Blue Blue
White
Green
PLC
+24V DC
-0V

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 09
Website: Email:
www.dadisick.com sale@dadisick.com
Accessories
2. Installation method of side right angle bracket
(Original accessories)
Side mounting bracket Model:QCA-05
Unit:mm
T-screw Model:QCA-02-1
Flange nut M6 Model:QCA-02-2
Unit:mm
Unit:mm
R2
10
R2
M6
10
16
17 M6
2
R7
R3
R5
14
R1
R1
14
6
3. Installation method of convex nut
(Optional accessories)
1. Installation method of T-shaped screws on the back
(Original accessories)
31
R2
13 613
17
4
R3 R2
33
2
47
13 613
R3
14
23
R10
Unit:mm
10
10 5
M5
2
3
2 2
6
M5
Raised nut Model:QCA-03-1
Unit:mm
M5 screw Model:QCA-03-2
5
12 17
9

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 10
Website: Email:
www.dadisick.com sale@dadisick.com
Model:QA-02
4.Installation method of right angle brackets
at both ends
(Order separately)
5.Shockproof installation method of
right angle brackets at both ends
(Order separately)
Shockproof right angle brackets Model:QA-01
42
R5
9R4
20 28
25 R3
R10
36
R5
R13
R3 R5
36
28
20
3
3
26
53 48
5614 65
Unit:mm
28
2.5
36
20
R6.2
5
28
R6.2
35
25
35 25
49.6
45.13
2.5
35
25
35
45.13
60
25
20
8
Unit:mm
Right angle brackets at both ends

SAFETY LIGHT CURTAIN USER'S MANUAL
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 11
Website: Email:
www.dadisick.com sale@dadisick.com
6.Stainless steel bracket installation
(Order separately)
Stainless steel bracket installation Model:QCA-01
Clip:
Aluminum round:
Aluminum arm:
33 32.4 10.5
7
R11
R17.5
5.8
5.5
75.9
R3.3 R3.3
11 6.5 2.5
6.5
3.8
6.5
14
14
7 35
90
25 R7
R4
3
14
6.0 8
37 16
5.5
14
8.5
8
R8
R20
25 40 25
56 3 14 314
68
6.5
8.5
41 15
5.5
14
8.5
8
2816
200
R10
R8
22.2
21.8
R11 7.5
6
13
4
13
200
R5.5
R3
10 16 5
11
20
30
4.5 11
10
20
7
6
11.2
1.2
Steel pipe:
Length: 400/500/600/700/800/1000 optional
Unit:mm
R11

Before installation, please open the packing box first, check the packed components according to the packing list,
and turn off the power supply of the machine tool at the beginning of installation to avoid danger.
INSTALL
WARNING
1、Installation direction
The installation direction of the light emitting device and the light receiving device should be consistent.
Emitter Receiver Emitter Receiver
2、Reflection from the ground and walls
When installing it as below, the light reflected from the surface of wall and flat is not shaded. Please check whether
it operates normally or not with a sensing target before using. (interval distance: ≥ 0.5 m)
Emitter Receiver
Emitter Receiver
Sensing target
Reflecting light
Reflecting light
Sensing target
Floor Wall
3、For protection of interference
It may cause interference when installing more than 2 sets of the sensor. In order to avoid the interference of
the sensor, please install as following figures and use the transmitted light frequency changing function.
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 12
Website: Email:
www.dadisick.com sale@dadisick.com
• Transmission direction should be opposite between 2 sets.
Emitter 1
Receiver 1 Emitter 2 Receiver 2
Emitter 2 Receiver 2
Emitter 1 Receiver 1
Cable Cable Cable
Cable
SAFETY LIGHT CURTAIN USER'S MANUAL

DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 13
Website: Email:
www.dadisick.com sale@dadisick.com
Emitter 1Receiver 1
Emitter 2 Receiver 2 Emitter 2 Receiver 2
Emitter 1 Receiver 1
Emitter 1Receiver 1
Emitter 2 Receiver 2
Emitter 1 Receiver 1
Emitter 2 Receiver 2
• Baffle should be installed between 2 sets.
Emitter 1 Receiver 1 Emitter 2 Receiver 2
Baffle
•Interval distance adjustment:
① Depending on the environment, it may vary;
② Do not use it directly under high-speed and high-frequency fluorescent lamps.
D(mm)
L(mm)
L (sensing distance) L (installation allowable distance)
0.1~1m
≥1m
≥0.1m
≥0.2m
SAFETY LIGHT CURTAIN USER'S MANUAL

Protection height≥ machine slide stroke + adjustment amount
WARNING
Safety distance is one of the necessary conditions to ensure that the photoelectric protection device realizes the
protection function, the safety distance must be calculated correctly, and the safety distance must be ensured during
installation!
1、the determination of height position
The height position refers to the position of the light curtain of the photoelectric protection device relative to the
upper and lower die ports of the machine tool, that is, under the premise of ensuring a safe distance, the lowest beam
of light of the photoelectric protection device shall not be higher than the lower edge of the lower die mouth, and the
top beam of light shall not be lower than the upper edge of the upper die port.
This involves the selection of the protection height of the photoelectric protection device
Incorrect installation position
(light curtain is too close to the die port to stop in time)
Protection height:H
Upper mold
Installation distance
=Ds
Lower mold
Correct installation location
Protection height:H
Upper mold
Installation distance
=Ds
Lower mold
Incorrect installation position
(light curtain is too high, human hand can reach under the light curtain)
Protection height:H
Upper mold
Installation distance
=Ds
Lower mold
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 14
Website: Email:
www.dadisick.com sale@dadisick.com
SAFETY LIGHT CURTAIN USER'S MANUAL

Incorrect installation position
(light curtain is low, human hand can reach out from the top of the light curtain)
Upper mold
Lower mold
Installation distance
=Ds
Protection height:H
A. The height position is one of the necessary conditions to ensure that the photoelectric protection device realizes
the protection function, and the height position must be ensured correctly during installation.
B. If the mold is replaced during use, the safety distance and height position must be readjusted according to the
above two requirements.
WARNING
2. Setting of auxiliary protective measures
When the horizontal distance between the light cuain plane of the photoelectric protection device and the front end
of the mold base exceeds 400mm, auxilia photoelectric or protective fences should be installed to prevent the
operator's body from entering the inside of the light cuain plane. When it is less than 400mm, safety measures such
as auxilia photoelectric or protective fence can also be taken.
Incorrect installation position
(too far from the die port for people to enter the danger zone)
Protection height:H
Upper mold
Installation distance
=Ds
Lower mold
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD We resee the right to make technical changes
2023-04-11 15
Website: Email:
www.dadisick.com sale@dadisick.com
SAFETY LIGHT CURTAIN USER'S MANUAL
Table of contents
Other DADISICK Security Sensor manuals
Popular Security Sensor manuals by other brands

Xintex
Xintex G-1BB-24-R Owner's Manual & Installation Instructions

LEGRAND
LEGRAND Wattstopper IDP 3050-A User reference guide

MSA
MSA altair 5 operating manual

Powerfix Profi
Powerfix Profi HG00384B Operation and safety notes

VOLTCRAFT
VOLTCRAFT LSG-10 operating instructions

Sanwa
Sanwa KDP10 instruction manual