www.DaikinApplied.com 5 CAT 258 • REBEL APPLIED ROOFTOP
Rebel Applied provides an adaptive cabinet design that gives
HVAC system designers exibility to congure solutions
unique to each customer to better serve better solutions for
applications that require greater indoor air quality (IAQ), energy
eciency, control and redundancy.
Rebel Applied is designed to provide engineered cabinet
exibility to give HVAC system designers the exibility to
minimize footprint, and congure equipment solutions unique
to each customer.
Footprint
Up to 40% shorter and 30% lighter than legacy rooftops, Rebel
Applied is easier to install. Congurable construction in 4”
increments of length lowers replacement costs by eliminating
large transition curbs and simplifying the installation process.
Rebel Applied makes designing mechanical systems easier by
oering airow congurations for horizontal supply and return
duct connections
Congure the airow path to meet building requirements in
healthcare, industrial, education and oce applications. Air
path exibility gives designs exibility to congure solutions
unique to each customer to better serve applications that
require greater indoor air quality, energy eciency and
redundancy.
• Energy Recovery
• UV lights
• Extra Access Sections
• Chilled Water
• Hot Water/Steam Sections
• Sound Attenuators
• Air Blenders
• Humidier Grids
• Final Filtration Sections
• Fan Array Backdraft Dampers
• Out of Air Stream Vestibules
Filtration, temperature, humidity control, and sound are all
important considerations when designing HVAC systems
for indoor air quality. The congurability of Rebel Applied
helps design indoor air quality solutions by providing exibile
air handling options for ltration, humdication and sound
attenuation.
• Filtration: Rebel Applied has exible ltration options to
satisfy indoor air requirements from varying space types.
—Pleated Filter Options: MERV 8 or 13 Filtration
eciencies in 2" or 4" lters exceed the AHSRAE
62 minimum MERV 6 required to keep the HVAC
equipment clean and operating eciently.
—Rigid Cartridge Filters: 98% of the particulate count
in outside air is less than 0.5 µm. For adequate
ltration of these particles a MERV 13 or higher lter
is required. MERV 14 Cartridge lters are 75-85%
ecient in 0.3-1 µm particle size and oer a longer
lter life than pleated MERV 13 lters. Rebel Applied
is available of MERV 11,14, 16 Filtration in the draw-
through or nal position
—HEPA Filtration: 99.97% ecient particle capture;
these lters are used for life-safety protection in
critical care applications like hospitals and clinics.
—Carbon or Gas Phase Filtration: Rebel Applied
can be supplied with other lter media to help
with applications in contaminated ventilation air
environments like air ports or in spaces where odors
may need to be ltered out of the supply air
• Temperature Control: Rebel Applied can be congured
for varying levels of temperature and humidity control in
both heating and cooling operating ranging from staged
capacity control to fully modulating capacity control
designed to provide +/-1°F supply air temperature control.
• Dehumidication/Humidication: Indoor humidity control
is a critical component for occupant health. High humidity
supports dust mites and allergies and can result in
material degradation and mold. Low humidity dry’s out
mucous membranes in humans which increased risk of
illness.
• Acoustics: Daikin Rebel Applied rooftops oer fan and
air handling congurability to optimize sound for each
application. Perforated Liners and factory mount sound
attenuators provide single source solution to meet space
sound requirements
Congurable Cabinetry makes it easy to design your Rebel
Applied rooftop to t to an existing Trane®Intellipak®or Daikin
RoofPak® curb without requiring expensive adapter curbs or
prolonged downtime during replacement.