
Table of contents
Installer reference guide
3
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P587502-1B – 2020.12
6.2.1 About opening the units................................................................................................................................. 58
6.2.2 To open the outdoor unit............................................................................................................................... 58
6.2.3 To remove the transportation stay................................................................................................................ 59
6.2.4 To close the outdoor unit............................................................................................................................... 59
6.2.5 To open the indoor unit ................................................................................................................................. 60
6.2.6 To lower the switch box on the indoor unit .................................................................................................. 62
6.2.7 To close the indoor unit ................................................................................................................................. 63
6.3 Mounting the outdoor unit............................................................................................................................................. 63
6.3.1 About mounting the outdoor unit ................................................................................................................. 63
6.3.2 Precautions when mounting the outdoor unit.............................................................................................. 63
6.3.3 To provide the installation structure ............................................................................................................. 63
6.3.4 To install the outdoor unit ............................................................................................................................. 64
6.3.5 To provide drainage........................................................................................................................................ 65
6.3.6 To install the discharge grille.......................................................................................................................... 67
6.3.7 To remove the discharge grille, and put the grille in safety position............................................................ 68
6.4 Mounting the indoor unit ............................................................................................................................................... 70
6.4.1 About mounting the indoor unit.................................................................................................................... 70
6.4.2 Precautions when mounting the indoor unit................................................................................................. 70
6.4.3 To install the indoor unit ................................................................................................................................ 70
6.4.4 To connect the drain hose to the drain ......................................................................................................... 71
7 Piping installation 73
7.1 Preparing water piping ................................................................................................................................................... 73
7.1.1 Water circuit requirements............................................................................................................................ 73
7.1.2 Formula to calculate the expansion vessel pre-pressure .............................................................................. 75
7.1.3 To check the water volume and flow rate ..................................................................................................... 75
7.1.4 Changing the pre-pressure of the expansion vessel...................................................................................... 78
7.1.5 To check the water volume: Examples .......................................................................................................... 78
7.2 Connecting water piping................................................................................................................................................. 79
7.2.1 About connecting the water piping ............................................................................................................... 79
7.2.2 Precautions when connecting the water piping............................................................................................ 79
7.2.3 To connect the water piping .......................................................................................................................... 79
7.2.4 To connect the recirculation piping ............................................................................................................... 82
7.2.5 To fill the water circuit ................................................................................................................................... 82
7.2.6 To protect the water circuit against freezing ................................................................................................ 82
7.2.7 To fill the domestic hot water tank................................................................................................................ 85
7.2.8 To insulate the water piping .......................................................................................................................... 86
8 Electrical installation 87
8.1 About connecting the electrical wiring .......................................................................................................................... 87
8.1.1 Precautions when connecting the electrical wiring....................................................................................... 87
8.1.2 Guidelines when connecting the electrical wiring......................................................................................... 88
8.1.3 About electrical compliance........................................................................................................................... 89
8.1.4 About preferential kWh rate power supply................................................................................................... 89
8.1.5 Overview of electrical connections except external actuators ..................................................................... 90
8.2 Connections to the outdoor unit.................................................................................................................................... 91
8.2.1 To connect the electrical wiring to the outdoor unit .................................................................................... 91
8.2.2 To reposition the air thermistor on the outdoor unit ................................................................................... 97
8.3 Connections to the indoor unit ...................................................................................................................................... 98
8.3.1 To connect the main power supply................................................................................................................ 101
8.3.2 To connect the backup heater power supply ................................................................................................ 103
8.3.3 To connect the shut-off valve ........................................................................................................................ 105
8.3.4 To connect the electricity meters .................................................................................................................. 106
8.3.5 To connect the domestic hot water pump .................................................................................................... 107
8.3.6 To connect the alarm output ......................................................................................................................... 108
8.3.7 To connect the space cooling/heating ON/OFF output................................................................................. 109
8.3.8 To connect the changeover to external heat source..................................................................................... 110
8.3.9 To connect the power consumption digital inputs........................................................................................ 111
8.3.10 To connect the safety thermostat (normally closed contact) ....................................................................... 112
8.4 After connecting the electrical wiring to the indoor unit .............................................................................................. 113
9 Configuration 115
9.1 Overview: Configuration................................................................................................................................................. 115
9.1.1 To access the most used commands ............................................................................................................. 116
9.2 Configuration wizard....................................................................................................................................................... 118
9.3 Possible screens .............................................................................................................................................................. 119
9.3.1 Possible screens: Overview ............................................................................................................................ 119
9.3.2 Home screen................................................................................................................................................... 120
9.3.3 Main menu screen.......................................................................................................................................... 123
9.3.4 Menu screen................................................................................................................................................... 124