
Table of contents
Installer reference guide
3
EPRA08~12EAV3+W1 + ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663478-1B – 2022.07
7.1 Preparing the installation site......................................................................................................................................... 66
7.1.1 Installation site requirements of the outdoor unit........................................................................................ 66
7.1.2 Additional installation site requirements of the outdoor unit in cold climates............................................ 69
7.1.3 Installation site requirements of the indoor unit .......................................................................................... 69
7.2 Opening and closing the units ........................................................................................................................................ 71
7.2.1 About opening the units................................................................................................................................. 71
7.2.2 To open the outdoor unit............................................................................................................................... 71
7.2.3 To remove the transportation stay................................................................................................................ 71
7.2.4 To attach the compressor cover piece .......................................................................................................... 72
7.2.5 To close the outdoor unit............................................................................................................................... 72
7.2.6 To open the indoor unit ................................................................................................................................. 73
7.2.7 To lower the switch box of the indoor unit and remove the top cover........................................................ 74
7.2.8 To close the indoor unit ................................................................................................................................. 76
7.3 Mounting the outdoor unit............................................................................................................................................. 76
7.3.1 About mounting the outdoor unit ................................................................................................................. 76
7.3.2 Precautions when mounting the outdoor unit.............................................................................................. 76
7.3.3 To provide the installation structure ............................................................................................................. 76
7.3.4 To install the outdoor unit ............................................................................................................................. 77
7.3.5 To provide drainage........................................................................................................................................ 78
7.3.6 To install the discharge grille.......................................................................................................................... 80
7.3.7 To remove the discharge grille, and put the grille in safety position............................................................ 81
7.3.8 To prevent the outdoor unit from falling over .............................................................................................. 83
7.4 Mounting the indoor unit ............................................................................................................................................... 83
7.4.1 About mounting the indoor unit.................................................................................................................... 83
7.4.2 Precautions when mounting the indoor unit................................................................................................. 84
7.4.3 To install the indoor unit ................................................................................................................................ 84
7.4.4 To connect the drain hose to the drain ......................................................................................................... 84
8 Piping installation 86
8.1 Preparing water piping ................................................................................................................................................... 86
8.1.1 Water circuit requirements............................................................................................................................ 86
8.1.2 To check the water volume and flow rate ..................................................................................................... 89
8.2 Connecting water piping................................................................................................................................................. 90
8.2.1 About connecting the water piping ............................................................................................................... 90
8.2.2 Precautions when connecting the water piping............................................................................................ 90
8.2.3 To connect the water piping .......................................................................................................................... 90
8.2.4 To connect a pressure vessel ......................................................................................................................... 95
8.2.5 To fill the heating system ............................................................................................................................... 95
8.2.6 To protect the water circuit against freezing ................................................................................................ 97
8.2.7 To fill the heat exchanger inside the storage tank ........................................................................................ 100
8.2.8 To fill the storage tank.................................................................................................................................... 100
8.2.9 To insulate the water piping .......................................................................................................................... 102
9 Electrical installation 103
9.1 About connecting the electrical wiring .......................................................................................................................... 103
9.1.1 Precautions when connecting the electrical wiring....................................................................................... 103
9.1.2 Guidelines when connecting the electrical wiring......................................................................................... 104
9.1.3 About electrical compliance........................................................................................................................... 105
9.1.4 About preferential kWh rate power supply................................................................................................... 106
9.1.5 Overview of electrical connections except external actuators ..................................................................... 106
9.2 Connections to the outdoor unit.................................................................................................................................... 107
9.2.1 To connect the electrical wiring to the outdoor unit .................................................................................... 108
9.2.2 To reposition the air thermistor on the outdoor unit ................................................................................... 114
9.3 Connections to the indoor unit ...................................................................................................................................... 115
9.3.1 To connect the electrical wiring to the indoor unit....................................................................................... 117
9.3.2 To connect the main power supply................................................................................................................ 119
9.3.3 To connect the backup heater power supply ................................................................................................ 121
9.3.4 To connect the backup heater to the main unit............................................................................................ 124
9.3.5 To connect the shut-off valve ........................................................................................................................ 125
9.3.6 To connect the electricity meters .................................................................................................................. 126
9.3.7 To connect the domestic hot water pump .................................................................................................... 127
9.3.8 To connect the alarm output ......................................................................................................................... 128
9.3.9 To connect the space cooling/heating ON/OFF output................................................................................. 129
9.3.10 To connect the changeover to external heat source..................................................................................... 130
9.3.11 To connect the power consumption digital inputs........................................................................................ 131
9.3.12 To connect the safety thermostat (normally closed contact) ....................................................................... 133
9.3.13 To connect a Smart Grid................................................................................................................................. 134
9.3.14 To connect the WLAN cartridge (delivered as accessory)............................................................................. 139
9.3.15 To connect the solar input ............................................................................................................................. 140
9.3.16 To connect the DHW output .......................................................................................................................... 140