SiBE341001
Table of Contents ii
1.2 Check Operation ....................................................................................65
1.3 Checking in Normal Operation ...............................................................68
2. Field Setting from Outdoor Unit.............................................................69
2.1 Field Setting from Outdoor Unit..............................................................69
Part 6 Troubleshooting ............................................................... 92
1. Symptom-based Troubleshooting .........................................................94
2. Troubleshooting by Remote Controller .................................................97
2.1 The INSPECTION / TEST Button...........................................................97
2.2 Self-diagnosis by Wired Remote Controller ...........................................98
2.3 Remote Controller Service Mode ...........................................................99
2.4 Test Run Mode.....................................................................................102
2.5 Remote Controller Self-Diagnosis Function .........................................102
2.6 “E1” Outdoor Unit: PCB Defect .............................................................110
2.7 “E2” Outdoor Unit: Actuation of High Pressure Switch..........................111
2.8 “E3” Outdoor Unit: Actuation of High Pressure Switch..........................112
2.9 “E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................114
2.10 “E5” Outdoor Unit: Inverter Compressor Motor Lock.............................116
2.11 “E7” Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................118
2.12 “E9” Outdoor Unit: Malfunction of Electronic
Expansion Valve Coil (Y1E~Y3E) ........................................................121
2.13 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature..................123
2.14 “F4” Outdoor Unit: Humidity alarm ........................................................125
2.15 “F9” Outdoor Unit : Malfunction of BS Unit Electronic
Expansion Valve...................................................................................127
2.16 “H7” Outdoor Unit: Abnormal Outdoor Fan Motor Signal ......................129
2.17 “H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....131
2.18 “J3, J4, J5, J6, J7, J8, J9” Outdoor Unit: Malfunction
of Outdoor unit Thermistor ...................................................................132
2.19 “JA” Outdoor Unit: Malfunction of High Pressure Sensor......................134
2.20 “JC” Outdoor Unit: Malfunction of Low Pressure Sensor ......................136
2.21 “L1” Outdoor Unit: Malfunction of Inverter PCB ....................................138
2.22 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................140
2.23 “L5” Outdoor Unit: Momentary Overcurrent of Inverter Compressor ....142
2.24 “L8” Outdoor Unit: Momentary Overcurrent of Inverter Compressor ....144
2.25 “L9” Outdoor Unit: Inverter Compressor Starting Failure ......................146
2.26 “LC” Outdoor Unit: Malfunction of Transmission between Inverter
and Main PCB ......................................................................................149
2.27 “P1” Outdoor Unit: Inverter Over-Ripple Protection...............................151
2.28 “P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................153
2.29 “PJ” Outdoor Unit: Faulty Field Setting after Replacing Main PCB or
Faulty Combination of PCB ..................................................................154
2.30 “U1” Reverse Phase, Open Phase ........................................................156
2.31 “U2” Outdoor Unit: Power Supply Insufficient
or Instantaneous Failure.......................................................................157
2.32 “U3” Outdoor Unit: Check Operation is not Executed............................160
2.33 “U4” Malfunction of Transmission between Indoor Units
and Outdoor Units ................................................................................162
2.34 “U7” Outdoor Unit: Transmission Failure (Across Outdoor Units) .........165