Si39-504
Table of Contents iii
3.5 “A7” Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................175
3.6 “A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E) ........................................................177
3.7 “AF” Indoor Unit: Drain Level above Limit..............................................179
3.8 “AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........180
3.9 “C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................181
3.10 “C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........182
3.11 “C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........183
3.12 “CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................184
3.13 “E1” Outdoor Unit: PC Board Defect ......................................................185
3.14 “E3” Outdoor Unit: Actuation of High Pressure Switch ..........................186
3.15 “E4” Outdoor Unit: Actuation of Low Pressure Sensor ..........................187
3.16 “E5”Outdoor Unit: Compressor Motor Lock ..........................................188
3.17 “E6”Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............189
3.18 “E7”Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................190
3.19 “E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................192
3.20 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................194
3.21 “F6”Outdoor Unit: Refrigerant Overcharged.........................................195
3.22 “H7”Outdoor Unit: Abnormal Outdoor Fan Motor Signal.......................196
3.23 “H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....197
3.24 “J2”Outdoor Unit: Current Sensor Malfunction ....................................198
3.25 “J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31~33T) .....................................................................................199
3.26 “J5” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe ...200
3.27 “J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger Deicer...................................................201
3.28 “J7” Outdoor Unit: Malfunction of Receiver Outlet Liquid
Pipe Thermistor (R6T)..........................................................................202
3.29 “J9” Outdoor Unit: Malfunction of Subcooling Heat Exchanger
Gas Pipe Thermistor (R5T) ..................................................................203
3.30 “JA” Outdoor Unit: Malfunction of High Pressure Sensor......................204
3.31 “JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................205
3.32 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................206
3.33 “L5” Outdoor Unit: Inverter Compressor Abnormal ...............................207
3.34 “L8” Outdoor Unit: Inverter Current Abnormal.......................................208
3.35 “L9” Outdoor Unit: Inverter Start up Error..............................................209
3.36 “LC” Outdoor Unit: Malfunction of Transmission Between
Inverter and Control PC Board .............................................................210
3.37 “P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................212
3.38 “P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................213
3.39 “UO” Outdoor Unit: Low Pressure Drop Due to Refrigerant
Shortage or Electronic Expansion Valve Failure ..................................214
3.40 “U1”Reverse Phase, Open Phase.........................................................215
3.41 “U2” Outdoor Unit: Power Supply Insufficient or
Instantaneous Failure...........................................................................216
3.42 “U3”Outdoor Unit: Check Operation not executed................................218
3.43 “U4”Malfunction of Transmission Between Indoor Units ......................219