11
CAUTION
Do not expose the low pressure
transducer to hot air of a dryer for
excess time.
Otherwise, the transducer may be damaged.
7.1
Low pressure transducer (LPT)
The LPT is located in the refrigerant circuit.
The operating low pressure value is displayed
on the controller indication panel.
(1) Replacing the transducer
q
Disconnect the lead wire from the control box.
w In order to prevent refrigerant from flowing
out, disconnect the low-pressure transducer
piping from the gauge joint (with check valve)
C on the compressor side.
e Remove two screws on the clamp plate fixing
low pressure transducer in place, and cut the
binding bands.
tInsert the pressure transducer cable through
the heat shrinkage tube, and connect the
union joint and connector to the new low
pressure transducer. If paint on the low
pressure transducer is peeled off, apply clear
lacquer.
rRemove the heat shrinkage tube, and
disconnect the connector from the low
pressure transducer.
qClamp plate
wBinding band
wBinding band
Flare nut
Union joint
Low pressure transducer
Heat shrinkage tube
Model LXE10E-A26B,A26C,A26D,A26E
Transducer type
NSK-BC010F
Identification
color
Transducer
Black body
Connector
Nothing
Flare nut
Union joint
Low pressure transducer
7. Transducer
7.2
High pressure transducer (HPT)
The HPT is located in the refrigerant circuit.
The operating high pressure value is displayed
on the controller indication panel.
(1) Replacement procedure
The replacement procedure is the same as
that for the low pressure transducer.
Make sure that the fixing position and the
cable connection is correct.
yApply the heat shrinkage tube in the following
position, then shrink it with hot air of a dryer.
uApply sealer between the heat shrinkage tube
and the flare nut. (Sealer :KE4898)
iFix the low pressure transducer with the
clamp plate, and fix the cable with the binding
band.
Fix the shrinkage tube end of the cable side
downward for prevention of water entering
into the tube.
rDryer
Make the heat shrinkage
tube fit in this area
Gauge
pipe side
Low pressure
transducer cable side
qHeat shrinkage tube
wConnector eFlare nut
qClamp plate
Fix the tube directing
the end downward
wBinding band
Model LXE10E-A26B,A26C,A26D,A26E
Transducer type
NSK-BC030F
Identification
Transducer
Red & Brown body
Connector
Nothing
01-12SGLXE10E-A26B,C11.1.1810:37AMページ11