SimpleSetTM Field Programming
Thisfeatureisusedfortransferringthecongurationfromthemastertothetargetthermostat.All
thermostatsforajobcanbemountedandpoweredup.Congureonethermostat.Thiswillbethe
master.Themasterwillbeusedtocopythecongurationtotherestofthethermostats.
Preparing the master to Send:
1. Themastermustbepoweredwith24VAC.
2. VerifythemasterthermostatisinOFFmode.
3. PressSYS(left)buttonuntilOFFmodedisplays.
4. Removecoverofthemasterthermostatbygentlypullingnearoneofthe
cornersatthetopofthethermostat.
5. PresstheupanddownbuttonsandCONFIGswitchsimultaneouslyfor5
seconds.
6. TheOUTscreendisplaysindicatingthemasterthermostatisreadyto
transferdata.
Note:PresstheupanddownbuttonsandCONFIGswitchsimultaneouslyfor
5secondstoexitfromdatatransfermodeandtoreturnthemasterto
theOFFmode.
7. Turnoffpowertothemasterandremoveitfromthewall.
8. Connectthemastertothetargetusingthe3wireconnector.Attachone
endtotheMaster’sFPpinsandtheotherendtotheTarget’sFPpins.
Note:Target thermostat must be powered with 24 VAC for eld programming
to occur.
Whentheconnectionhasbeenmadecorrectly,themasterthermostatwillpowerupandthetargetwill
countfrom5downto1.ItwillthendisplaytheLOCKconrmingthedatahasbeensavedinmemory.
Whenalltargetthermostatshavebeencompleted,reinstallthemasterthermostat.
PresstheupanddownbuttonsandtheCONFIGswitchsimultaneouslyfor5secondstoexitfrom
thedatatransfermodeandtoreturnthemasterthermostattotheOFFmode.
OFF
Requires SimpleSetTM Transfer Cable (668817901)
Daikin Training and Development
Now that you have made an investment in modern, efficient Daikin equipment, its care should be a high priority. For
training information on all Daikin HVAC products, please visit us at www.DaikinApplied.com and click on Training,
or call 540-248-9646 and ask for the Training Department.
Warranty
All Daikin equipment is sold pursuant to its standard terms and conditions of sale, including Limited Product
Warranty. Consult your local Daikin Representative for warranty details. Refer to Form 933-430285Y. To find your
local Daikin Representative, go to www.DaikinApplied.com.
Aftermarket Services
To find your local parts office, visit www.DaikinApplied.com or call 800-37PARTS (800-377-2787). To find your
local service office, visit www.DaikinApplied.com or call 800-432-1342. This document contains the most current
product information as of this printing. For the most up-to-date product information, please go to
www.DaikinApplied.com.
Products manufactured in an ISO certified facility.
LIAF014-110-15-13
Lockout Feature
TheDaikinthermostathasabuttonlockoutfeaturesothemodecannotbe
changedandthetemperatureadjustmentislimited.Selecttheappropriate
lockoutfromCongurationModeSettings(Step5)ofthisguide.
ToactivatetheLOCKfeature:
1. SimultaneouslypresstheSYS,FANandUPbuttonsfor10seconds.
2. willdisplayandthelockoutfunctionwillbeenabled.
TodeactivatetheLOCKfeature,repeatsteps1and2above.
Operating Modes
TherearefourpossibleoperatingmodesfortheDaikinthermostat.Off,Cool,Heat,andCool&Heat
modesareaccessedbypressingtheSYS(left)button.Programmodeisaccessedbypressingthe
SYS(left)andFAN(right)buttonssimultaneously.
Cool Mode
• Inthismode,thethermostatcontrolsthecoolingsystem.Whenthe
coolingoutputs,thesnowakeicon apprearsonthedisplay.
Note:There is a four minute delay for your compressor to restart after
it has turned off.
OFF Mode
• Inthismode,thethermostatwillnotturnontheheatingorcoolingdevices
Note:The indoor fan can be turned on manually in every operating
mode by pressing the FAN (right) button. The word FAN
shows on the display and the fan icon appears when the fan
operates.
Cool and Heat Mode (Auto Changeover)
• Inthismode,thethermostatcontrolsthecoolingandheatingsystems,
automaticallychangingoverfromonetotheotherasneeded.
• Thetimingdisplayalternateswiththesettemperatureevery10seconds
inthecoolandheatmode.
Heat Mode
• Inthismode,thethermostatcontrolstheheatingsystem.Whentheheat
outputs,theameicon apprearsonthedisplay.
Note:For heat pumps, there is a four minute delay for your
compressor to restart after it has turned off.
Testing the Thermostat
Oncethethermostatiscongured,itshouldbethoroughlytested.
Heat Test
1. PressSYS(left)buttonuntilheatmodeisdisplayed.
2. Adjustthesettemperaturesoitis5degreesabovetheroomtemperature.
3. Heatshouldcomeonwithinafewseconds.RedLEDmayturnon.
4. Adjustthesettemperature2degreesbelowtheroomtemperatureandthe
heatshouldturnoff.Theremaybeafandelayonyoursystem.
Note:
Forheatpumps,thereisafour-minutedelaytoprotectyourcompressorafteritturnsoff.
Tobypassthecompressortimedelay,gotoOFFmodefor5seconds.
Cool Test
1. PressSYS(left)buttonuntilcoolmodeisdisplayed.
2. Adjustsettemperaturesoitis5degreesbelowroomtemperature.
3. A/Cshouldcomeonwithinafewseconds.GreenLEDmayturnON.
4. Adjustthesettemperature2degreesabovetheroomtemperatureand
theA/Cshouldturnoff.Theremaybeafandelayonyoursystem.
Note:
Thereisafour-minutetimedelaytoprotectthecompressorafteritturnsoff.To
bypassthecompressortimedelay,gotoOFFmodefor5seconds.
Fan Test
1. PressFAN(right)button.Fandisplays.IndoorfanturnsON.
2. PressFAN(right)button.IndoorfanturnsOFF.
CAUTION
Donotenergizetheairconditioningsystemwhentheoutdoortemperatureisbelow50degrees.
Itcanresultinequipmentdamageorpersonalinjury.
Mode of Operation
TheDaikinthermostatisanautochangeover,single-stageheat,single-stagecoolthermostat.It
functionswithairconditioning,heatpumps,gas,oilorelectricheatsystems.
Thethermostatactivatestheheatingappliancewhentheroomtemperatureisbelowthesetheat
temperature(bythedifferentialtemperature)andtheredindicatorlight(congurable)onthe
thermostatwilllight.Thethermostatwillstopoutputtingandtheredlightwillturnoffwhenthecallfor
heathasbeensatised.Withheatpumps,thethermostatwillnotletthecompressorcomeonfor4
minutesafteritturnsoff.Thisprotectsyourcompressor.
Whentheroomtemperatureisgreaterthanthesetcooltemperature(bythedifferentialtemperature),
thecoolingdeviceisactivatedandthegreenindicatorlight(congurable)onthethermostatwill
turnon.Thethermostatwillstopoutputtingandthegreenlightwillturnoffwhenthecallforcooling
issatised.Thethermostatwillnotletthecompressorcomeonfor4minutesafteritturnsoff.This
protectsyourcompressor.
Thethermostathasfourpossibleoperatingmodes:OFF,Heat,Cool,andHeat & Coolmode.Inoff
mode,thethermostatwillnotturnonheatingorcoolingdevices.The manual fan can be turned on in
all operating modes using the fan switch and the fan speed can be set in all operating modes using
the fan speed switch.Inheatmode,thethermostatcontrolstheheatingsystem.Inthecoolmode,the
thermostatcontrolsthecoolingsystem.Inheat&coolmode,thethermostatcontrolsboththeheating
andcoolingsystems.Theclockdisplayalternateswiththesettemperaturedisplayforheat&cool
mode.
Thethermostatalsohasabuttonlockoutfeature.Thisenablesthethermostattobesettotheproper
modeandtemperatureandlockedsoitcannotbetamperedwith.
12.Status Indicator Light(Led0or1)
0=Statusindicatorneveron
1=Statusindicatoronwithrststage
Presstheupordownbuttontoselect.
PresstheCONFIGbuttonfor2secondstoexitconguration.
OFF
11. Cooling Fan Delay Off Time(0,30,60,90seconds)
Selectthefanpurgetimeforcooling.
Presstheupordownbuttontoselect.
Presstherightbuttontoadvancetothenextscreen.
10.Temperature Sensor(1-3)
1.Onlyon-boardsensordeterminesroomtemperature.
2.Onlyremotesensordeterminesroomtemperature.
3.Averagetemperatureofon-boardandremotesensor.
Presstheupordownbuttontoselect.
Presstherightbuttontoadvancetothenextscreen.
9. Maximum Cycles Allowed Per Hour(--,2-6)
--=asmanyasneeded,2-6=maximumcycles/hour
Presstheupordownbuttontoselect.
Presstherightbuttontoadvancetothenextscreen.
7. Minimum Cool Setpoint(45°Fto90°F)(7°Cto32°C)
Adjusttocontroltheminimumcoolsettemperatureallowed.
Presstheupordownbuttontoselect.
Presstherightbuttontoadvancetothenextscreen.
8. Room Temperature Offset(+9°Fto-9°F)(+4.5°Cto-4.5°C)
Adjusttocalibratedisplayedroomtemperaturetomatchactualroom
temperature.
Note:When not set to 0, will display.
Presstheupordownbuttontoselect.
Presstherightbuttontoadvancetothenextscreen.
Troubleshooting
Symptom Remedy
Nodisplay Checkfor24VACatthermostat;displayisblankwhen24
VACisnotpresent
Systemfandoesnotcomeonproperly Verifywiringiscorrect,checkGas/ElectricConguration
(seeSetting)
Allthermostatbuttonsareinoperative Verify24VACispresent;unitlocksoutwhen24VACis
notpresent
Noresponsewithrstbuttonpress Firstbuttonpressactivatesbacklightonly
Thermostatturnsonandofftoo
frequently
Adjusttemperaturedifferential(seeCongurationMode
Setting2)
Fanrunscontinuously PressFAN(right)buttontoturnfanoff
Statusindicatorlightnotonduringcall Turnstatusindicatorfunctionon(seeCongurationMode
Setting12)
Roomtemperatureisnotcorrect Calibratethermostat(seeCongurationModeSetting8)
Ifremotesensorisused,checkS1andS2terminal
connections
displayswhenanybuttonis
pressed
Thermostathasthebuttonlockoutfunctionactivated(see
LockoutFeatureandCongurationModeSetting5)
ondisplayinsteadofroomtemp. CheckforabadconnectionatS1andS2terminals,if
used(seeCongurationModeSetting10)
HeatorCoolnotcomingon Verifywiringiscorrect,verifyRC/RHjumperisinplace
(forsingletransformersystem)
Remoteoroutdoorsensornotaccurate PressSYSandDownbuttonssimultaneouslytodisplay
remoteoroutdoortemperature.VerifyconnectionsatS1
andS2terminals.
Problemnotlistedabove PressResetbuttononce*
* Reset Button Function:
Timeanddayarereset,congurationsettingsareunchanged.
FPpins
S1 S2 R C W
O/B GY1W2 W3Y2
RESET CONFIG
FP