➢TECHNICAL NOTE
INSTALLATION:
•CAUTION: The product may only be connected and installed by qualified personnel. All applicable regulations, legislation, and building
codes in force in the respective countries must be observed. Incorrect installation of the product can cause irreparable damage to the
product and the connected LEDs.
Pay attention when connecting the LEDs: polarity reversal results in no light output and often damages the LEDs.
•Isolate the mains supply before the installation or adjusting the device. Installation and maintenance must be performed in the absence
of AC Voltage.
•The product must be installed inside a switchgear/controlgear cabinet and/or junction box protection against overvoltage.
•If required, the product must be protected by a suitably sized fuse.
•The external supply must be protected. The product must be protected by a properly sized Miniature Circuit Breaker (MCB) with
overcurrent protection.
•The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically. Other positions are
not permitted. The bottom position is not permitted (label/top cover facing down).
•Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit.
•It is absolutely forbidden to connect, for any reason, directly or indirectly, the 230Vac mains voltage to the BUS terminals.
•If required, the product must be dissipated correctly.
•Use the product in harsh environments could limit the output power.
•Maintenance must be performed only by a qualified electrician in compliance with current regulations.
•Before powering the device, the cover of the product must be correctly placed in its seat and closed by securing all 4 closing hooks. The
device must absolutely not be powered without the cover of the product or with the cover of product not properly closed.
COMMAND and OUTPUT
•The length and type of cables connecting to the bus (DMX, DALI other) must comply with the specifications of the respective protocols and
the regulations in force. They must be insulated from any wiring or non-SELV voltage parts. It is recommended to use double insulated
cables.
•ALL device and control signal connect at the BUS (DMX DALI other) must be SELV type (the device connected must be SELV or supply SELV
signal).
WARNING: Do not compromise the correct functioning of the device, the product must not be in any way shielded and/or installed inside
metal and aluminium boxes.
As any other Casambi product, should not be placed in a metal enclosure or next to large metal structures. Metal will effectively block all
radio signals which are crucial to the operation of the product.