BRM-DM1
BRM-DM1
GMS Basic Refiner Module
INSTALLATION MANUAL
dametric

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 2 of 6
1DOCUMENTREVISION.......................................................................................................................................2
2ARTICLENUMBERSKCANDVALMET..................................................................................................................2
3USERMANUAL..................................................................................................................................................2
4TECHNICALSPECIFICATION................................................................................................................................2
5INSTALLATION...................................................................................................................................................3
5.1GENERAL....................................................................................................................................................................3
5.2CONNECTORPLACING...................................................................................................................................................3
5.3CONNECTORJ1,+24VDC,CAN‐1.................................................................................................................................3
5.3.1InputsfortheSSMfunctionoption................................................................................................................3
5.4CONNECTORJ2,AGS/CPMINTERFACE(OPTION)..............................................................................................................4
5.5CONNECTORJ3,CMD,DIGITALOUTPUTS........................................................................................................................4
5.6CONNECTORJ4,POM,VIM,TVD.................................................................................................................................5
5.7CONNECTORJ5,HPM,OTM,AIN.................................................................................................................................5
5.8CONNECTORJ11,ETHERNET..........................................................................................................................................5
5.9CONNECTORJ12,USB.................................................................................................................................................5
6CONTACT...........................................................................................................................................................6
1 Document revision
Feb. 1, 2018/BL First release.
June 5, 2018/BL Added connection of K-AGP25 and K-CAN1P25.
Aug. 7, 2018/BL Added CEC and SSM-functions.
Oct. 1, 2018/BL Small corrections.
Oct. 20. 2018/BL Fixed connection J3/17 to J2/17.
Oct. 14, 2019/BL Clarified termination of CAN-bus to AGS (5.4).
2 Article number SKC and Valmet
Unit SKC Valmet
BRM-DM1 SKC2594365 VAL0399295
BRM-DM2 SKC2601904 VAL0405083.
3 User manual
See document ”BRM-DM12 UM EN YYMMDD.pdf” regarding how to use the unit.
4 Technical specification
See document ”BRM-DM12 TS EN YYMMDD.pdf” regarding the technical specification.

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 3 of 6
5 Installation
5.1 General
This manual shows all connections to the module. Some of the functions are however not activated in the
BRM-DM1 variant.
All connections are done to 20-pole connectors with spring loaded sockets.
Maximum allowed conduit area is 1.5mm2 or AWG 16. Do not use clamping sleeves.
The strip length should be 10mm (0.40 inch). A too short a length might make the cable
loose, at too long, the result will be a piece of non-isolated cable.
The cable shields should be joined with a 1.0 mm2 isolated cable and then mounted to the
connector.
5.2 Connector placing
5.3 Connector J1, +24VDC, CAN-1
1,2 +24VDC Power supply to the module
3,4 0VDC Power ground
5,6 CAN1-H CAN1-interface H-signal (use twisted pair cable for
CAN1-H and CAN1-L)
7,8 CAN1-L CAN1-interface L-signal
9,10 CAN1-R CAN1-interface termination pole (jumper between 9 and 10 for 120 termination)
11,12 0VDC Signal ground
13 DI 1 Digital input 1
14 DI 2 Digital input 2
15 DI 3 Digital input 3
16 DI 4 Digital input 4
17 DI 5 Digital input 5
18 DI 6 Digital input 6
19 DI 7 Digital input 7
20 DI 8 Digital input 8
5.3.1 Inputs for the SSM function option
Use DI7 and DI8 as inputs for the Safeset supervision option.
J1/19 DI7 Connect to pulse sensor for the motor side.
J1/20 DI8 Connect to pulse sensor for the refiner side.
USB

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 4 of 6
5.4 Connector J2, AGS/CPM interface (option)
1,2 +24VDCin Power supply input for AGS/CPM
3,4 0VDC Power ground
5,6 +24VDCout Power supply output to AGS/CPM
7,8 0VDC Power ground
9,10 CAN2-H CAN2-interface H-signal (use twisted pair cable for
CAN2-H and CAN2-L)
11,12 CAN2-L CAN2-interface L-signal
13,14 CAN2-R CAN2-interface termination pole (jumper between 13 and 14 for 120 termination)
15,16 CAN2-C CAN2-interface common (for cable shielding)
17,18 0VDC Signal ground
19,20 0VDC Signal ground
Connect K-AGP25 according to the figure. Cut away excessive
wires.
GY=grey, BU = blue, PK = pink, RD = red, SH = shield.
Connect K-AGP25 according to the figure.
(WH/BU = white / blue, BU/WH = blue /white, SH = shield
A jumper between 13 and 14 terminates the bus with 120 .
5.5 Connector J3, CMD, Digital outputs
1,2 +24VDCin The power supply input for the CMD system
3,4 0VDC The power ground
6,8,10,12 0VDC The power ground
5 SM-WA1 To control motor winding
7 SM-WA2 To control motor winding
9 SM-WB1 To control motor winding
11 SM-WB2 To control motor winding
13 DO1 Digital output 1
14 DO2 Digital output 2
15 DIO3 Digital output 3
16 DIO4 Digital output 4
17 DIO5 Digital output 5
18 DIO6 Digital output 6
19 DI7 Digital output 7
20 DI8 Digital output 8
1
2
19
20
BRM‐DM1 A+
A‐
B+
B‐
GND
J3/5
J3/7
J3/9
J3/11
J3/12
CM‐2NM...
Step
motor
A+
A‐
B+
B‐
GND
1
2
3
4
GND
K‐CM25K
BRM‐DM1 GY(+24V)
BU(+24V)
PK(0V)
RD(0V)
SH
J2/5
J2/6
J2/7
J2/8
J2/17
K‐AGP25
BRM‐DM1 WH/BU
BU/WH
SH
J2/9
J2/11
J2/15
J2/13
J2/14
K‐CAN1P25

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 5 of 6
5.6 Connector J4, POM, VIM, TVD
1 POM-T1 K-POT25/white (to POT-50 transducer)
2 POM-T2 K-POT25/brown
3 POM-T3 K-POT25/green
4 POM-T4 K-POT25/yellow
5 POM-T5 K-POT25/grey
6 POM-T6 K-POT25/rose
7 0VDC K-POT25/shield
8 0VDC Signal ground
9 VIM-EP K-VIMS25/white (to VIM-T2 transducer)
10 VIM-SP K-VIMS25/brown
11 VIM-SN K-VIMS25/green
12 VIM-EN K-VIMS25/yellow
13 0VDC K-VIMS25/shield
14 0VDC Signal ground
15 TVD-EP K-TVDS25/white (to TVD-T2 transducer)
16 TVD-SP K-TVDS25/brown
17 TVD-SN K-TVDS25/green
18 TVD-EN K-TVDS25/yellow
19 0VDC K-TVDS25/shield
20 0VDC Signal ground
5.7 Connector J5, HPM, OTM, AIN
HPM-A and HPM-B measures two pressure transmitters.
1 HPM-SAP HPM-A, Analog input, positive, 4-20mA
2 HPM-SAN HPM-A, Analog input, negative, 4-20mA
3 HPM-SBP HPM-B, Analog input, positive, 4-20mA
4 HPM-SBN HPM-B, Analog input, negative, 4-20mA
5,6 0VDC Signal ground
OTM-1 and OTM-2 measures PT100 sensors in a 3-wire connection.
The compensating and negative wires are internally connected in the transducer end.
7 OTM-E1 OTM-1, Excitation, PT-100
8 OTM-S1 OTM-1, Compensation, PT-100
9 OTM-N1 OTM-1, Negative, PT-100
10 0VDC Signal ground
11 OTM-E2 OTM-2, Excitation, PT-100
12 OTM-S2 OTM-2, Compensation, PT-100
13 OTM-N2 OTM-2, Negative, PT-100
14 0VDC Signal ground
15,16 0VDC Signal ground
MPM and AIN measures active 4-20mA input signals, that is – the electrical current loop is not
powered from the BRM unit.
17 MPM-IP MPM analog input, positive (4-20mA)
18 MPM-IN MPM analog input, negative (4-20mA)
19 AIN-P Analog input, positive (4-20mA)
20 AIN-N Analog input, negative (4-20mA)
5.8 Connector J11, Ethernet
RJ45 connector for the Ethernet cable.
Connect the cable to the switch of the local GMS network.
5.9 Connector J12, USB
USB-A connector for a memory stick.
1
2
19
20
1
2
19
20

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 6 of 6