Dametric BRM-DM1 User manual

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 1 of 6
BRM-DM1
BRM-DM1
GMS Basic Refiner Module
INSTALLATION MANUAL
dametric

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 2 of 6
1DOCUMENTREVISION.......................................................................................................................................2
2ARTICLENUMBERSKCANDVALMET..................................................................................................................2
3USERMANUAL..................................................................................................................................................2
4TECHNICALSPECIFICATION................................................................................................................................2
5INSTALLATION...................................................................................................................................................3
5.1GENERAL....................................................................................................................................................................3
5.2CONNECTORPLACING...................................................................................................................................................3
5.3CONNECTORJ1,+24VDC,CAN‐1.................................................................................................................................3
5.3.1InputsfortheSSMfunctionoption................................................................................................................3
5.4CONNECTORJ2,AGS/CPMINTERFACE(OPTION)..............................................................................................................4
5.5CONNECTORJ3,CMD,DIGITALOUTPUTS........................................................................................................................4
5.6CONNECTORJ4,POM,VIM,TVD.................................................................................................................................5
5.7CONNECTORJ5,HPM,OTM,AIN.................................................................................................................................5
5.8CONNECTORJ11,ETHERNET..........................................................................................................................................5
5.9CONNECTORJ12,USB.................................................................................................................................................5
6CONTACT...........................................................................................................................................................6
1 Document revision
Feb. 1, 2018/BL First release.
June 5, 2018/BL Added connection of K-AGP25 and K-CAN1P25.
Aug. 7, 2018/BL Added CEC and SSM-functions.
Oct. 1, 2018/BL Small corrections.
Oct. 20. 2018/BL Fixed connection J3/17 to J2/17.
Oct. 14, 2019/BL Clarified termination of CAN-bus to AGS (5.4).
2 Article number SKC and Valmet
Unit SKC Valmet
BRM-DM1 SKC2594365 VAL0399295
BRM-DM2 SKC2601904 VAL0405083.
3 User manual
See document ”BRM-DM12 UM EN YYMMDD.pdf” regarding how to use the unit.
4 Technical specification
See document ”BRM-DM12 TS EN YYMMDD.pdf” regarding the technical specification.

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 3 of 6
5 Installation
5.1 General
This manual shows all connections to the module. Some of the functions are however not activated in the
BRM-DM1 variant.
All connections are done to 20-pole connectors with spring loaded sockets.
Maximum allowed conduit area is 1.5mm2 or AWG 16. Do not use clamping sleeves.
The strip length should be 10mm (0.40 inch). A too short a length might make the cable
loose, at too long, the result will be a piece of non-isolated cable.
The cable shields should be joined with a 1.0 mm2 isolated cable and then mounted to the
connector.
5.2 Connector placing
5.3 Connector J1, +24VDC, CAN-1
1,2 +24VDC Power supply to the module
3,4 0VDC Power ground
5,6 CAN1-H CAN1-interface H-signal (use twisted pair cable for
CAN1-H and CAN1-L)
7,8 CAN1-L CAN1-interface L-signal
9,10 CAN1-R CAN1-interface termination pole (jumper between 9 and 10 for 120 termination)
11,12 0VDC Signal ground
13 DI 1 Digital input 1
14 DI 2 Digital input 2
15 DI 3 Digital input 3
16 DI 4 Digital input 4
17 DI 5 Digital input 5
18 DI 6 Digital input 6
19 DI 7 Digital input 7
20 DI 8 Digital input 8
5.3.1 Inputs for the SSM function option
Use DI7 and DI8 as inputs for the Safeset supervision option.
J1/19 DI7 Connect to pulse sensor for the motor side.
J1/20 DI8 Connect to pulse sensor for the refiner side.
USB

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 4 of 6
5.4 Connector J2, AGS/CPM interface (option)
1,2 +24VDCin Power supply input for AGS/CPM
3,4 0VDC Power ground
5,6 +24VDCout Power supply output to AGS/CPM
7,8 0VDC Power ground
9,10 CAN2-H CAN2-interface H-signal (use twisted pair cable for
CAN2-H and CAN2-L)
11,12 CAN2-L CAN2-interface L-signal
13,14 CAN2-R CAN2-interface termination pole (jumper between 13 and 14 for 120 termination)
15,16 CAN2-C CAN2-interface common (for cable shielding)
17,18 0VDC Signal ground
19,20 0VDC Signal ground
Connect K-AGP25 according to the figure. Cut away excessive
wires.
GY=grey, BU = blue, PK = pink, RD = red, SH = shield.
Connect K-AGP25 according to the figure.
(WH/BU = white / blue, BU/WH = blue /white, SH = shield
A jumper between 13 and 14 terminates the bus with 120 .
5.5 Connector J3, CMD, Digital outputs
1,2 +24VDCin The power supply input for the CMD system
3,4 0VDC The power ground
6,8,10,12 0VDC The power ground
5 SM-WA1 To control motor winding
7 SM-WA2 To control motor winding
9 SM-WB1 To control motor winding
11 SM-WB2 To control motor winding
13 DO1 Digital output 1
14 DO2 Digital output 2
15 DIO3 Digital output 3
16 DIO4 Digital output 4
17 DIO5 Digital output 5
18 DIO6 Digital output 6
19 DI7 Digital output 7
20 DI8 Digital output 8
1
2
19
20
BRM‐DM1 A+
A‐
B+
B‐
GND
J3/5
J3/7
J3/9
J3/11
J3/12
CM‐2NM...
Step
motor
A+
A‐
B+
B‐
GND
1
2
3
4
GND
K‐CM25K
BRM‐DM1 GY(+24V)
BU(+24V)
PK(0V)
RD(0V)
SH
J2/5
J2/6
J2/7
J2/8
J2/17
K‐AGP25
BRM‐DM1 WH/BU
BU/WH
SH
J2/9
J2/11
J2/15
J2/13
J2/14
K‐CAN1P25

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 5 of 6
5.6 Connector J4, POM, VIM, TVD
1 POM-T1 K-POT25/white (to POT-50 transducer)
2 POM-T2 K-POT25/brown
3 POM-T3 K-POT25/green
4 POM-T4 K-POT25/yellow
5 POM-T5 K-POT25/grey
6 POM-T6 K-POT25/rose
7 0VDC K-POT25/shield
8 0VDC Signal ground
9 VIM-EP K-VIMS25/white (to VIM-T2 transducer)
10 VIM-SP K-VIMS25/brown
11 VIM-SN K-VIMS25/green
12 VIM-EN K-VIMS25/yellow
13 0VDC K-VIMS25/shield
14 0VDC Signal ground
15 TVD-EP K-TVDS25/white (to TVD-T2 transducer)
16 TVD-SP K-TVDS25/brown
17 TVD-SN K-TVDS25/green
18 TVD-EN K-TVDS25/yellow
19 0VDC K-TVDS25/shield
20 0VDC Signal ground
5.7 Connector J5, HPM, OTM, AIN
HPM-A and HPM-B measures two pressure transmitters.
1 HPM-SAP HPM-A, Analog input, positive, 4-20mA
2 HPM-SAN HPM-A, Analog input, negative, 4-20mA
3 HPM-SBP HPM-B, Analog input, positive, 4-20mA
4 HPM-SBN HPM-B, Analog input, negative, 4-20mA
5,6 0VDC Signal ground
OTM-1 and OTM-2 measures PT100 sensors in a 3-wire connection.
The compensating and negative wires are internally connected in the transducer end.
7 OTM-E1 OTM-1, Excitation, PT-100
8 OTM-S1 OTM-1, Compensation, PT-100
9 OTM-N1 OTM-1, Negative, PT-100
10 0VDC Signal ground
11 OTM-E2 OTM-2, Excitation, PT-100
12 OTM-S2 OTM-2, Compensation, PT-100
13 OTM-N2 OTM-2, Negative, PT-100
14 0VDC Signal ground
15,16 0VDC Signal ground
MPM and AIN measures active 4-20mA input signals, that is – the electrical current loop is not
powered from the BRM unit.
17 MPM-IP MPM analog input, positive (4-20mA)
18 MPM-IN MPM analog input, negative (4-20mA)
19 AIN-P Analog input, positive (4-20mA)
20 AIN-N Analog input, negative (4-20mA)
5.8 Connector J11, Ethernet
RJ45 connector for the Ethernet cable.
Connect the cable to the switch of the local GMS network.
5.9 Connector J12, USB
USB-A connector for a memory stick.
1
2
19
20
1
2
19
20

Dametric AB BRM-DM1/2 Installation manual
BRM-DM12 IM EN.docx October 14, 2019 Page 6 of 6
6 Contact
Sales, development, production and service:
Dametric AB
Jägerhorns Väg 19, 141 75 Kungens Kurva, Sweden
Phone: +46-8 556 477 00
e-mail: [email protected] Web site: www.dametric.se
dametric
Other manuals for BRM-DM1
1
Table of contents
Other Dametric Control Unit manuals
Popular Control Unit manuals by other brands

SKF
SKF Lincoln 85307 installation instructions

Linear Technology
Linear Technology DC1210A quick start guide

ARI
ARI VB-060 manual

Rockwell Automation
Rockwell Automation Allen-Bradley 1606-XLSBUFFER24 instruction manual

KERAFLO
KERAFLO AYLESBURY KB Series quick start guide

Potter
Potter PAD100-IM installation manual

Taoglas
Taoglas EDGE Locate quick start guide

Modentic
Modentic Y-Type Installation, operation & maintenance manual

ICP DAS USA
ICP DAS USA I-2533 quick start

ABB
ABB FEPL-02 Ethernet POWERLINK Quick installation and start-up guide

SMC Networks
SMC Networks IBV1 Series Operation manual

coval
coval LEMCOM quick start guide