Datalogic PWR-240B User manual

PWR-240B
INSTALLATION MANUAL
Reading Station Power Supply

Datalogic S.r.l.
Via S. Vitalino, 13
40012 Calderara di Reno (BO)
Italy
Tel. +39 051 3147011
Fax +39 051 3147205
©2020-2023 Datalogic S.p.A. and /or its affiliates
All rights reserved. Without limiting the rights under copyright, no part of this documentation may be
reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or
for any purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and
transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not
remove or alter any proprietary notices, including copyright notices, contained in this documentation and
shall ensure that all notices appear on any reproductions of the documentation.
Electronic versions of this document may be downloaded from the Datalogic website (www.data-
logic.com). If you visit our website and would like to make comments or suggestions about this or other
Datalogic publications, please let us know via the "Contact" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accu-
rate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein,
nor for incidental or consequential damages resulting from the use of this material. Datalogic reserves the
right to change any specification at any time without prior notice.
Trademarks
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including
the U.S.A. and the E.U.
All other trademarks and brands are property of their respective owners.

INSTALLATION MANUAL
iii
TABLE OF CONTENTS
PREFACE ..................................................................................................................IV
About this Manual ........................................................................................................... iv
Manual Conventions ........................................................................................................................... iv
Technical Support ........................................................................................................... iv
Support Through the Website ............................................................................................................ iv
Reseller Technical Support ................................................................................................................ iv
Safety Regulations ........................................................................................................... v
Electrical Safety ...................................................................................................................................v
Product Data Label .............................................................................................................................. v
CE Compliance ..................................................................................................................................... v
General View .................................................................................................................. vi
CHAPTER 1.
OPERATING FEATURES .........................................................................1
Description ...................................................................................................................... 1
Output Protection ............................................................................................................. 1
Light Overload .....................................................................................................................................1
CHAPTER 2.
PRE-INSTALLATION CHECKLIST ...........................................................3
System Wiring: DC Output ................................................................................................ 3
System Wiring: AC Input .................................................................................................. 4
System Wiring: Test ......................................................................................................... 4
CHAPTER 3.
MECHANICAL INSTALLATION................................................................5
Cabinet Mounting ............................................................................................................. 5
CHAPTER 4.
LOW VOLTAGE ELECTRICAL CONNECTIONS...........................................6
DC Low Voltage Cable Insertion ........................................................................................ 6
Cable Entry Plate .................................................................................................................................6
AS-I Cable Insertion ............................................................................................................................7
DC Voltage Terminal Block ............................................................................................... 7
DC OK Monitoring ................................................................................................................................8
DC Direct Output ..................................................................................................................................8
Laser Barcode Scanners ................................................................................................... 8
Supply Capacity When Wiring Directly to AS-I Compatible Scanners ..............................................8
AS-I Wiring Topologies .......................................................................................................................9
Installing Accessory Industrial Ethernet Switch ............................................................... 10
Route the Ethernet Cables through the Cable Entry Plate grommets to the devices. .......... 11
CHAPTER 5.
AC LINE VOLTAGE ELECTRICAL CONNECTIONS ................................... 12
AC Line Input Voltage ..................................................................................................... 12
12 Vdc Power Block Installation (Optional) ...................................................................... 14
CHAPTER 6.
TECHNICAL FEATURES ....................................................................... 16
APPENDIX A.
ELECTRICAL DIAGRAMS ................................................................... 17
PWR-240B Electrical Diagram ........................................................................................ 17

iv
PWR-240B
PREFACE
ABOUT THIS MANUAL
This Instruction Manual is provided for users seeking advanced technical information,
including installation, connections, maintenance and specifications.
Manual Conventions
The following conventions are used in this document:
The symbols listed below are used in this manual to notify the reader of key issues or
procedures that must be observed:
TECHNICAL SUPPORT
Support Through the Website
Datalogic provides several services as well as technical support through its website. Log
on to (www.datalogic.com).
For quick access, from the home page click on the search icon , and type in the name of
the product you’re looking for. This allows you access to download Data Sheets, Manu-
als, Software & Utilities, and Drawings.
Hover over the Support & Service menu for access to Services and Technical Support.
Reseller Technical Support
An excellent source for technical assistance and information is an authorized Datalogic
reseller. A reseller is acquainted with specific types of businesses, application software,
and computer systems and can provide individualized assistance.
NOTE: Contains important information necessary for proper installation
and use of the device.
CAUTION; This symbol advises you of actions that could damage equipment
or property.
HIGH VOLTAGE: This symbol alerts the user they are about to perform an
action involving, either a dangerous level of voltage, or to warn against an
action that could result in damage to devices or electrical shock. Opera-
tions having this symbol must be performed by qualified personnel only.

SAFETY REGULATIONS
INSTALLATION MANUAL
v
SAFETY REGULATIONS
Electrical Safety
This product conforms to the applicable requirements contained in the following Euro-
pean Standards:
• EN 61439-1
• EN 60204-1
• EN 60950-1 +A11 +A1 +A12 +A2
•EN62368-1
Product Data Label
The Product data label is located on the outside door panel.
Figure 1 – Product Data Label
CE Compliance
CE marking states the compliance of the product with essential requirements listed in
the applicable European directive. Since the directives and applicable standards are
subject to continuous updates, and since Datalogic promptly adopts these updates,
therefore the EU declaration of conformity is a living document. The EU declaration of
conformity is available for competent authorities and customers through Datalogic
commercial reference contacts. Since April 20th, 2016 the main European directives
applicable to Datalogic products require inclusion of an adequate analysis and assess-
ment of the risk(s). This evaluation was carried out in relation to the applicable points of
the standards listed in the Declaration of Conformity. Datalogic products are mainly
designed for integration purposes into more complex systems. For this reason, it is
under the responsibility of the system integrator to do a new risk assessment regarding
the final installation.
Warning
This is a Class A product. In a domestic environment this product may cause radio inter-
ference in which case the user may be required to take adequate measures.

PREFACE
vi
PWR-240B
GENERAL VIEW
Figure 2 - PWR-240B General View
1 Key Lock 6 Cooling Fan
2 Product Data Label 7 AC Line Input Terminal Block
3 AC Input Cable Compression Connector 8 Thermal-magnetic Circuit Breaker
4 Cable Entry Plate with Grommets 9 “DC OK” Terminal Block
5 Monophase Switching Power Supply 10 24 Vdc Terminal Block

INSTALLATION MANUAL
1
CHAPTER 1
OPERATING FEATURES
DESCRIPTION
The PWR-240B is an electrical cabinet housing a 24 Vdc power supply which is used to
power up a varying number of reading devices (depending on the product), along with
their relative accessory devices. See Chapter 4 for details.
As shown in the Electrical Diagram in Appendix A, the AC Input Line passes through a
protective thermo-magnetic circuit breaker and connects to the monophase switching
power supply.
The 24 Vdc output power is connected to the output terminal blocks through a direct
connection block. The direct connection block is protected by the internal power supply
features.
Two output power supply status monitoring signals (DC-OK) are provided to connect to
an optional digital alarm. If for some reason the output voltage is reduced by less than
90% of nominal) these lines open.
OUTPUT PROTECTION
This power supply is specifically designed to power Datalogic devices and implements
output protection according to the type of overload behavior.
Light Overload
Light Overload is defined as application of a load that results in a reduction of the out-
put voltage that remains above 13V. In this case the power supply can deliver up to 14
amperes continuously, see Figure 3 Overload Behavior. Datalogic devices by their nature

OPERATING FEATURES
2
PWR-240B
cannot cause overload conditions since they are equipped with intrinsic power monitor-
ing systems. The AIR CLEANING SYSTEM fans also have this function.
Figure 3 - Overload Behavior
Heavy Overload (including short-circuit)
Heavy Overload is defined as application of a load which causes a reduction in voltage
below 13V. This causes the power supply to enter HICCUP operation where power is
supplied for 2 seconds and then shuts off for 18 seconds. This procedure is repeated
until the short-circuit or overload is resolved, see Figure 4 Short-Circuit Protection HIC-
CUP Mode. For this condition, the maximum length of the power cables between the
power supply and the powered devices guarantees the behavior of a short-circuit down-
stream of this cable.
Figure 4 – Short-Circuit Protection HICCUP Mode

INSTALLATION MANUAL
3
CHAPTER 2
PRE-INSTALLATION CHECKLIST
This chapter can be used as a checklist to verify all the steps necessary to complete
installation of the PWR power supply.
1. Read all information in this manual before installation, paying particular attention
to all Caution and Warning notes.
2. Mount the PWR to the Station frame using the brackets and bolts provided in the
package. See "Cabinet Mounting" on page 5.
SYSTEM WIRING: DC OUTPUT
3. Connect your devices to the PWR according to your application.
Barcode Scanners
Correctly connect the AS-I cabling to the PWR using the AS-I cable wiring instruc-
tions for backbone and branch wiring. See "Laser Barcode Scanners" on page 8 and
your scanner manual for details.
All cables must pass through the cable entry plate using the correct AS-I cable
grommets as described in "Cable Entry Plate" on page 6 and "AS-I Cable Insertion"
on page 7.
HIGH VOLTAGE: Opening the cabinet requires a key that should be used by a
person adequately advised or supervised by an electrically skilled person
to enable him or her to perceive risks and avoid hazards which electricity
can create. Internal components guarantee an IP20 degree of protection
against direct contact.

PRE-INSTALLATION CHECKLIST
4
PWR-240B
SYSTEM WIRING: AC INPUT
4. To comply with EN 60950-1:2007 par.1.7.2.2, par. 2.7.1, par 2.7.4, par. 3.4.6, and to
protect the AC input connection to the device; a disconnecting device with built in
overcurrent and earth protection shall be installed external to the equipment
according to local regulations.
According to EN 60950-1:2007 par. 3.2.3; the AC input cable must have a maxi-
mum diameter of 14mm and the conduit a max diameter of 16mm.
5. With AC line voltage OFF, wire the AC Line to the AC Line Input Terminal Block see
"AC Line Input Voltage" on page 12.
SYSTEM WIRING: TEST
6. Apply the AC line voltage from the building installation or the DWS-SWITCH and
check that the PWR powers up correctly. The green DC-OK light should be on
steady and the overload light (red) should off.
7. Close and lock the PWR enclosure and check that it does not open (lock functions
correctly).
The PWR-240B installation is now complete.

INSTALLATION MANUAL
5
CHAPTER 3
MECHANICAL INSTALLATION
CABINET MOUNTING
The cabinet must be mounted to the reading station frame using the brackets and bolts
provided in the package.
1. Mount the bracket to the
cabinet.
2. Mount the cabinet to the
frame.
Figure 5 – Mounting Brackets
Figure 6 – PWR-240B cabinet max. height
Please note that the cabinet door can be unlocked and opened by using the key pro-
vided along with the product.
IMPORTANT: The cabinet must be installed vertically in such a way that the
key lock is no higher than 1.90 m from the ground (see Figure 6).
max. 190 cm

6
PWR-240B
CHAPTER 4
LOW VOLTAGE ELECTRICAL
CONNECTIONS
DC LOW VOLTAGE CABLE INSERTION
The Cable Entry Plate has several sealing grommets that must be inserted to provide
IP65 protection capability. This includes AS-I cable sealing grommets.
Cable Entry Plate
Follow these instructions to correctly insert the cables:
1. Determine the number and size of the cables coming into and leaving the PWR-
240B.
2. Unmount the Cable Entry Plate and select all the necessary grommets for your
application.
3. Insert the correct size sealing grommets and positions relative to these cables.
Unused positions must mount the closed grommets with their flat closed surface
facing the outside of the PWR.
4. Remount the Cable Entry Plate.
5. Press the cable end through the proper grommet so that it seals around the cable.
The Cable Entry Plate has 10 cable entry points with the following grommet kit supplied:
GROMMETS CABLE DIAMETER
QTY TYPE MM INCH
2 single
3 0.118
1 double
4 0.157
1 single
6 0.236
4 double
6 0.236
2 AS-I Cable form
- -
7 closed
- -

DC VOLTAGE TERMINAL BLOCK
INSTALLATION MANUAL
7
AS-I Cable Insertion
Prepare the AS-I cable by stripping the outer protection sheath leaving about 5 cm of
blue and brown wires free for positioning. Strip the individual wires for insertion into
the Terminal Block.
Figure 7 - AS-I Cable Prep
Pass the AS-I cable through the AS-I cable sealing grommet and make sure there is
enough length to easily reach the 24 Vdc Terminal Block.
Figure 8 – Cable Insertion
DC VOLTAGE TERMINAL BLOCK
Figure 9 – PWR-240B DC Output Power Connections
AS-I cable sealing
grommets
DC OK Signals
DC Outputs

LOW VOLTAGE ELECTRICAL CONNECTIONS
8
PWR-240B
DC OK Monitoring
The DC voltage terminal block provides two wiring terminals (13-14), which monitor the
status of the switching power supply (DC OK feature). When the power supply module
runs correctly, lines 13 and 14 form a normally closed contact. If the power module
experiences problems (i.e. output overload causing output voltage to be reduced by less
than 90% of nominal) these lines open. Lines 13 and 14 are decoupled from the power
output lines and can be connected to a free digital input to signal this alarm condition.
DC Direct Output
The 24 volt DC Output terminals are direct. Connect the output devices according to
your application requirements.
LASER BARCODE SCANNERS
Supply Capacity When Wiring Directly to AS-I Compatible Scanners
For direct wiring, power distribution is performed simultaneously for all the scanners.
However all the scanner motors start up slowly so that there is no significant peak cur-
rent draw. See the specific scanner manual for consumption data.
The maximum number of same type scanners to be supplied for direct wiring the PWR-
240B is shown in the table below and depends on the wiring topology:
The following products are also AS-I compatible: DS5100, DM3610, SC5000. In case of
networks using a mix of products, you must calculate the total power consumption so as
not to exceed the limits for the specific topology used. See the specific product refer-
ence manual in the Technical Features chapter for consumption data.
The power supply unit is connected directly to the scanners via AS-I cabling.
SCANNER TYPE MAXIMUM NUMBER OF SCANNERS BY
TOPOLOGY
DOUBLE BRANCH SINGLE BRANCH
DS8110
11 (balanced 6+5) 9
DX8210
11 (balanced 6+5) 9
AS-I Single Branch 200 W max
AS-I Double Branch 240 W max total (200 W max for a single branch)

LASER BARCODE SCANNERS
INSTALLATION MANUAL
9
Figure 10 - Connecting PWR-240B Directly to Scanners
Refer to the specific scanner manual for I/O interface wiring connections.
AS-I Wiring Topologies
Figure 11 – Single Branch Topology
24 Vdc to scanners using AS-I cabling
DC OK
AC in
device
nodes
24 Vdc AS-I single branch with end cap
200 W max

LOW VOLTAGE ELECTRICAL CONNECTIONS
10
PWR-240B
Figure 12 – Double Branch Topology
The load for Double Branches should be kept as balanced as possible. For example 6+5
or 5+4 scanners instead of 9+2.
INSTALLING ACCESSORY INDUSTRIAL ETHERNET SWITCH
An accessory 24 Vdc Industrial Ethernet Switch can be installed and powered from
inside the PWR-240B power supply.
Figure 13 - 24 Volt Industrial Ethernet Switch
device
nodes
24 Vdc AS-I double branch with end caps
240 W max total of all devices
200 W max for a single branch
24 Vdc Accessory Ethernet Switch
(purchased separately)
Ethernet Switch power cables
(included in PWR-240B package)

ROUTE THE ETHERNET CABLES THROUGH THE CABLE ENTRY PLATE GROMMETS TO THE DEVICES.
INSTALLATION MANUAL
11
Fix the Industrial Ethernet Switch to the DIN rain using the clips provided inside the
PWR and connect the power cables as shown in the figure below.
Figure 14 - Industrial Ethernet Switch Mounted Inside PWR-240B
Route the Ethernet Cables through the Cable Entry Plate grommets to the devices.

12
PWR-240B
CHAPTER 5
AC LINE VOLTAGE ELECTRICAL
CONNECTIONS
AC LINE INPUT VOLTAGE
Wire according to the following points:
• Primary wiring: Overcurrent protection should be provided by a 16 A building
installation circuit breaker. PWR-240B input components are rated for an Icp of 10
kA max.
• Wiring methods from the branch circuit breaker to the PWR-240B power supply
shall comply with the National Electric Code ANSI\NFPA. The Datalogic DWS-
SWITCH is an AC Power Disconnector and Distributor cabinet which provides this
protection.
• For primary wiring use a 3-conductor cable (between 2.5 mm2 - 4 mm2 (13 AWG –
11 AWG), for every conductor. Choose the overall cable diameter and UL Listed
conduits accordingly. The AC input cable must be inserted through the AC Input
Cable Compression Connector.
• The individual conductors must be inserted into the dedicated terminal blocks on
the DIN rail (see figure below) which are marked Line (L) neutral (N) and Protec-
tion Earth (PE).
• Replace the protection cover over the spring clamp connector after correctly
installing the wires.
HIGH VOLTAGE: This operation must be performed by a certified electrician.

AC LINE INPUT VOLTAGE
INSTALLATION MANUAL
13
Figure 15 – PWR-240B AC Line Terminal Block with Protection Covers
The terminal block marked with the ground symbol is a special block which allows direct
connection of the Protection Earth with the enclosure of the PWR-240B.
AC Line
terminal block
protection covers

AC LINE VOLTAGE ELECTRICAL CONNECTIONS
14
PWR-240B
12 VDC POWER BLOCK INSTALLATION (OPTIONAL)
A DC Power Block can be installed inside the PWR-240B to supply RFID devices with 12
Vdc.
Figure 16 - 12 Vdc Power Block
The DC Power Block connects to the AC input line and Its AC cord must be adapted to
connect to the PWR AC input terminal block.
Cut the power block AC cord to about 30 cm (12 in) from the female plug and strip the
individual wires about 4 cm (1.5 in).
Figure 17 - AC Cord Preparation
Fix the Power Block to the holder and connect the AC cord to the AC Line terminal block
as shown in the figure below.
Table of contents
Other Datalogic Power Supply manuals
Popular Power Supply manuals by other brands

Vertiv
Vertiv NetSure 7100 Compact Installation and user manual

PCB Piezotronics
PCB Piezotronics 441A101 Installation and operating manual

Altronix
Altronix Maximal1RHDV installation guide

Keithley
Keithley 2260B-30-36 Adjustment manual

MSA
MSA PS-303 Series operating manual

Magtrol
Magtrol DES 410 user manual