Switches, Indicators, and Controls
The 9325 has two sets of switches and indicators
controlling the operation of the two disks. Those
associated with the removable cartridge are located on
the left-hand side of the drive's front panel. The fixed
disk's indicators and switches are on the right-hand
side of the front panel. The main power switch, which
controls power to both drives,
is
located on the front
lower right-hand corner of the cabinet. The switches
and indicators on the 9324, 9326 and 9327 are similar.
POWER Switch
61626-02
The main POWER switch, located on the lower
right-hand corner of the 9325 front panel,
is
a
two-position rocker switch. Set the switch to the
ON
position to power on both drives in the 9325 and begin
the start-up cycle for the fixed disk
(see
Figure
2).
Before powering off the disks, ensure all tasks using
the 9325 are finished and the LOAD light
is
on,
indicating the cartridge drive
is
ready to load.
To
start
the cartridge unload
cycle,
set the
START/STOP
toggle
switch to STOP and wait until the
IDAD
light comes
on before powering off. This prevents possible damage
to the disk
by
ensuring the read/write mechanism
is
retracted from the disk surface.
If
this sequence
is
not
followed, the cartridge door remains locked and the
cartridge cannot be removed.
To
power off the disks,
set the switch to the
OFF
position.
9324/25/26/27 OPERATING
GUIDE