Dataq DI-1110 User manual

The way PC-based instrumentation should be
DI-1110
8-Channel USB Data Acquisition Starter Kit
User's Manual
Manual Revision C
Copyright © 2020 by DATAQ Instruments, Inc. The Information contained herein is the exclusive property of
DATAQ Instruments, Inc., except as otherwise indicated and shall not be reproduced, transmitted, transcribed, stored
in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic,
mechanical, magnetic, optical, chemical, manual, or otherwise without expressed written authorization from the com-
pany. The distribution of this material outside the company may occur only as authorized by the company in writing.
DATAQ Instruments' hardware and software products are not designed to be used in the diagnosis and treatment of
humans, nor are they to be used as critical components in any life-support systems whose failure to perform can rea-
sonably be expected to cause significant injury to humans.
DATAQ, the DATAQ logo, and WINDAQ are registered trademarks of DATAQ Instruments, Inc. All rights reserved.
DATAQ Instruments, Inc.
241 Springside Drive
Akron, Ohio 44333 U.S.A.
Telephone: 330-668-1444
Fax: 330-666-5434
Designed and manufactured in the
United States of America


iii
Warranty and Service Policy
Product Warranty
DATAQ Instruments, Inc. warrants that this hardware will be free from defects in materials and workmanship under
normal use and service for a period of 90 days from the date of shipment. DATAQ Instruments' obligations under this
warranty shall not arise until the defective material is shipped freight prepaid to DATAQ Instruments. The only
responsibility of DATAQ Instruments under this warranty is to repair or replace, at its discretion and on a free of
charge basis, the defective material.
This warranty does not extend to products that have been repaired or altered by persons other than DATAQ Instru-
ments employees, or products that have been subjected to misuse, neglect, improper installation, or accident.
DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the
sale, installation, or use of its products.
Service Policy
1. All products returned to DATAQ Instruments for service, regardless of warranty status, must be on a freight-pre-
paid basis.
2. DATAQ Instruments will repair or replace any defective product within 5 days of its receipt.
3. For in-warranty repairs, DATAQ Instruments will return repaired items to the buyer freight prepaid. Out of war-
ranty repairs will be returned with freight prepaid and added to the service invoice.

iv

DI-1110 Hardware Manual
Table of Contents
v
Table of Contents
Warranty and Service Policy ................................................................................................................ iii
1. Introduction ........................................................................................................................................ 1
Features .............................................................................................................................................. 1
Analog Inputs .................................................................................................................................... 1
Digital Inputs ..................................................................................................................................... 1
Software ............................................................................................................................................. 1
WinDaq Dashboard ..................................................................................................................... 2
WinDaq® Recording and Playback Software ............................................................................ 2
Help ............................................................................................................................................. 2
2. Specifications ...................................................................................................................................... 3
3. Installation .......................................................................................................................................... 5
Install WinDaq Software ................................................................................................................... 5
Connect the Instrument to Your Computer ....................................................................................... 6
4. Controls, Indicators, and Connections ............................................................................................. 7
Mini-B USB Connection ................................................................................................................... 7
Screw Terminals ................................................................................................................................ 7
DI-1110 Signal Connections ....................................................................................................... 8
Connecting Signal Leads ............................................................................................................ 8
Analog Inputs .............................................................................................................................. 9
Digital Ports ................................................................................................................................ 9
WinDaq Remote Events (Evnt/D0) ...................................................................................... 10
WinDaq Remote Storage (Rcrd/D1) .................................................................................... 12
WinDaq Rate (Rate/D2) ....................................................................................................... 12
WinDaq Counter (Cnt/D3) ................................................................................................... 14
General Purpose Digital Inputs ............................................................................................ 16
General Purpose Digital Outputs .......................................................................................... 17
4-20mA Current Loop Measurements ............................................................................................... 18
LED Indicator .................................................................................................................................... 19
5. Unlock WinDaq .................................................................................................................................. 21
6. Dimensional Drawing ......................................................................................................................... 23


DI-1110 Hardware Manual
Introduction
1
1. Introduction
This manual contains information designed to familiarize you with the features and functions of the DI-1110 USB
data acquisition starter kit. These high-end Starter kits contain features and functionality normally reserved for more
expensive data acquisition systems.
Features
The DI-1110 data acquisition instrument is a portable data recording module that communicates through your com-
puter's USB port. Power is derived from the interface port so no external power is required. Features include:
• 4 or 8 fixed differential analog inputs protected to ±100V (transient).*
• ±10V full scale measurement range.
• 12-bit analog-to-digital resolution.
• 7 digital ports* protected to +25V: Two dedicated for WINDAQ remote control operations; One dedicated to
WINDAQ rate measurements; and One dedicated to WINDAQ counter measurements.
• Up to 160 kHz maximum throughput sampling rate.
• A push-button to tag remote events in WINDAQ software.
• LED indication for easy notification of system status.
• Free WinDaq/Lite data acquisition recording software.
• Included .Net Class supports programming the DI-1110 under any .Net programming language.
• Fully documented instrument protocol for programming the device in operating systems other than Windows.
* WinDaq/Unlock required to record more than four total channels when using WinDaq software.
Analog Inputs
The DI-1110 features eight differential channel inputs (WinDaq/Unlock required to record more than four total chan-
nels when using WinDaq software) located on a single sixteen-position screw terminal block for easy connection and
operation (other terminals used for digital I/O or reserved). Note: The DI-1110 does not support Gain.
Utilize the functionality of WINDAQ software to experience all the features encased in these small, inexpensive
instruments.
Digital Inputs
The DI-1110 contains seven digital ports (WinDaq/Unlock required to record more than four total channels when
using WinDaq software), which may be used as a general-purpose digital inputs or for a specific function as desig-
nated on the device. Digital port D0 is reserved for WinDaq Events; Digital port D1 is reserved for WinDaq remote
Start/Stop; Digital port D2 is reserved for rate measurements; Digital port D3 is reserved for counts; Please Note:
Digital outputs are not supported in WinDaq software. Each port may be configured as a switch using third-party
software.
Software
All software required to record and playback waveforms is included with the purchase of any DI-1110 data acquisi-
tion starter kit via download.

DI-1110 Hardware Manual
Introduction
2
WinDaq Dashboard
The WinDaq Dashboard utility allows you to start WinDaq software with your Dataq devices. Units available for syn-
chronized recording using ChannelStretch™ are shown in compatible blocks of devices (the DI-1110 does not sup-
port ChannelStretch or stand-alone data logging).
WINDAQ®Recording and Playback Software
WINDAQ Acquisition and WINDAQ Waveform Browser allow you to record and playback data acquired through your
instrument. WINDAQ software is an invaluable resource to record and analyze your data and is available for free from
our web site (www.dataq.com).
WINDAQ Acquisition software can be used to record waveforms directly and continuously to disk while monitoring a
real time display of the waveforms on-screen. It operates, displays, and records waveform signals in real time at the
full sample rate of the DI-1110.
WINDAQ Waveform Browser playback software (also known as “WWB”) offers an easy way to review and analyze
acquired waveforms. A built-in data file translator allows the user to display multiple waveforms acquired by
WINDAQ Acquisition software or any of a wide range of data acquisition packages. The software’s disk-streaming
design allows data files of any length to be graphically displayed rapidly, in normal or reverse time directions. Seven
standard cursor-based measurements, frequency domain, and statistical analysis functions help simplify waveform
analysis and interpretation. WINDAQ Waveform Browser is free and installed when installing WINDAQ Software.
Help
All WINDAQ software utilizes context-sensitive help. Help may be accessed through the Help menu or by pressing
the F1 key with any pull-down menu item selected. This will take you directly to the Help topic most relevant to that
particular function or feature. Help topics discuss in detail each function available in the software.

DI-1110 Hardware Manual
Specifications
3
2. Specifications
Analog Inputs
Number of Channels: 8
Channel Configuration: Differential
Full Scale Range: ±10 V
Input impedance: 1M
Absolute accuracy:
@ 25°C, excluding common mode error
±12.5 mV @ 25°C
Absolute maximum input without damage:
±75 V peak, continuous
±100 V peak, one minute or less
System noise: 7.8 mV rms
Max common mode voltage: ±10 V
Common mode rejection ratio: 40 dB (dc - 60 Hz)
Channel-to-channel crosstalk rejection: -80 dB
Digital Ports
Number of Ports: 7
Type: MOSFET switch
Configuration: Programmable as digital input or switch
Programmed as a Switch
Maximum drain voltage: 25 V
Maximum sink current: 100 mA
Count/Rate/Inputs
Internal pull-up value: 4.7 k
Input high voltage threshold: 2.4V
Input low voltage threshold: 0.8V
Terminal count: 65,535
Maximum rate frequency: 50 KHz with one enabled channel, 20 KHz with 2-4 enabled channels, 10
KHz with 5-8 enabled channels, else 5 KHz.
Minimum rate frequency: 0.5Hz
Maximum count frequency: 50 kHz
Absolute maximum applied voltage (V): +25V
Reserved Digital Inputs
D0: WINDAQ remote events
D1: WINDAQ remote start/stop
D2: Rate input
D3: Count input

DI-1110 Hardware Manual
Specifications
4
ADC Characteristics
Resolution: 12-bit
Above zero ADC counts: 2,047
Below zero ADC counts: 2,048
Voltage resolution (excluding noise): 4.86 mV
4-20 mA resolution (excluding noise): 818 adc counts with 250 shunt
Max. sample throughput rate: 160 kHz
Min. sample throughput rate: Hardware only: 20 Hz
WinDaq software: 2.2 samples per hour
Sample rate timing accuracy: 50 ppm
Indicators and Connections
Interface: USB 2.0 (mini-B style connector)
Indicator light: 3 LEDs; Power, Active, Event
Input connections: Two 16-position screw terminal strips
Power
Power Consumption: <1.0 Watt, via USB interface
Environmental
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Operating Humidity: 0 to 90% non-condensing
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
Storage Humidity: 0 to 90% non-condensing
Physical Characteristics
Enclosure: Polycarbonate ABS, 0.080 inch thickness
Mounting: Desktop; bulkhead
Dimensions: 2.625D × 5.5W × 1.53H in.
(6.67D × 13.97W × 3.89H cm.)
Weight: 5.7 oz. (162 grams)
Software Support
WINDAQ software: OS support: Check online at http://www.dataq.com/products/windaq/
windows-compatability/
Programming: DATAQ .NET Class, Instrument protocol, ActiveX Control

DI-1110 Hardware Manual
Installation
5
3. Installation
The following items are included with each DI-1110 USB Data Acquisition System. Verify that you have the follow-
ing:
• A DI-1110 USB data acquisition instrument.
• 6-foot USB cable.
• A DATAQ Instruments screwdriver for signal lead connections.
If an item is missing or damaged, call DATAQ Instruments at 330-668-1444. We will guide you through the appropri-
ate steps for replacing missing or damaged items. Save the original packing material in the unlikely event that your
unit must, for any reason, be sent back to DATAQ Instruments.
Install WINDAQ Software
All software for the DI-1110 can be installed via a downloadable executable directly from the DATAQ Instruments
web site. No CD is shipped with the device. You may burn the executable onto a CD or flash drive to transport the
software to a computer with no internet connection.
1. Disconnect all DATAQ Instruments USB devices from your Computer.
2. Download software at run.dataq.com.
3. Save the executable (Dataq Software Suite Web Setup.exe) to your local hard drive.
4. Double-click on the executable to extract the program and begin software installation.
5. Follow the on-screen prompts and enter all required information.

DI-1110 Hardware Manual
Installation
6
6. Software installation is complete - you will now see a “Successful Installation” box - click OK to exit WINDAQ
Installation.
You can now plug the device(s) into your PC. Click on the “WinDaq Dashboard” shortcut to access WINDAQ soft-
ware.
Connect the Instrument to Your Computer
DI-1110 instruments can be connected to your computer’s USB port using the provided USB cable. No external
power is required. Connect one end of the communications cable to the instrument port and the other to your PC’s
port.
Note: Use a powered USB hub or a USB port on your PC. Non-powered USB hubs may not have sufficient power to
run the instrument.

DI-1110 Hardware Manual
Controls, Indicators, and Connections
7
4. Controls, Indicators, and
Connections
Please note: The SD card slot is not used in the DI-1110. Allowing foreign materials to enter the device through the
SD card slot may result in damage to the instrument.
Mini-B USB Connection
Use the supplied USB cable to connect and power the instrument through your computer’s USB port.
Screw Terminals
All input signal connections are made to the 16-port screw terminals. Each terminal is labeled on the instrument case.
CAUTION
Do not touch the input terminals after signal cables are connected to the system under test,
since it will cause an electric shock.
To avoid ESD damage in handling the device, take the following precautions:
Ground yourself with a grounding strap or by touching a grounded object before and during
your handling of the instrument.
Analog In
Channels 1-8
Digital Ports
Power, Active, and
Remote LEDs
Event Marker
Push Button
Mini-B
USB Connection
SD Card Slot
(not used in DI-1110)
Bulkhead Mounting
Ear Bulkhead Mounting Ear
+5V
Excitation Ground
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8
!
!

DI-1110 Hardware Manual
Controls, Indicators, and Connections
8
DI-1110 Signal Connections
Refer to the following for screw terminal port identification.
Ch#: Analog channels 1-8 (±10 Volts Full Scale Fixed, ±100 V max.)
D#: Digital port (0-6). Can also be used for specific WINDAQ functions (25 Vmax).
Evnt/D0 — WINDAQ Remote Event Marker (or general-purpose)
Rcrd/D1 — WINDAQ Remote Start/Stop (or general-purpose)
Rate/D2 — Rate Input (or general-purpose)
Cnt/D3 — Counter Input (or general-purpose)
D4 to D6 — General-purpose digital ports
+5V: +5V out. Max current = 100mA.
GnD: Ground.
Connecting Signal Leads
Connect signal leads to the DI-1110:
1. Insert the stripped end of a signal lead into the desired terminal directly under the screw.
2. Tighten the pressure flap by rotating the screw clockwise with a small screwdriver. Make sure that the pressure
flap tightens only against the signal wire and not the wire insulation. Do not over-tighten.
3. Tug gently on the signal lead to ensure that it is firmly secured.
When an input signal is connected and WINDAQ Acquisition software is run, WINDAQ’s real time display immedi-
ately reveals the input waveform on your computer’s monitor.
www.dataq.com
+
-
+
-
+
-
+
-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+
-
+
-
+
-
+
-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
9
Analog Inputs
Eight differential analog inputs* measure ±10 Volts (CH1 to CH8, fixed). Designed to withstand ±120 V.
Use the following diagram to connect Analog Input Channel 1.
*WinDaq/Unlock required to record more than four total channels when using WinDaq software.
Digital Ports
The DI-1110 contains 7 general-purpose digital ports.* Each digital port can be configured as a digital input or used as
a switch to control an external load (up to 25 V and 100 mA). Many of the ports also provide specific functionality in
WINDAQ or a third-party program.
Evnt/D0 is for WINDAQ Remote Events. This bit inserts an event marker in your data.
Rcrd/D1 is for WINDAQ Remote Storage. This bit can be programmed to begin recording data.
Rate/D2 is for Rate measurements: 10Hz to 50kHz.
Cnt/D3 is for Counter/Timer measurements up to 65,536.
D4 to D6 are general-purpose digital inputs.
10K
1M
1M
10K
Ref
AIN
AIN
Signal + Signal -
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
10
Equivalent Digital I/O Circuit:
Valid remote record and event signals are switch closures or discrete levels with a maximum input of 25 V and a TTL
level threshold.
*WinDaq/Unlock required to record more than four total channels when using WinDaq software.
WINDAQ Remote Events (Evnt/D0)
To use a switch closure or TTL signal to record WINDAQ Event Markers, connect signal leads to the appropriate
Remote Control Event terminals on the DI-1110 as shown below.
Dig In Dx
Dx
10
4.7K
+5
4.7K
Control
3.3V
Switch Closure
TTL
0V
25V Max
TTL Threshold
Signal + Signal -
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
11
Once the switch closure or TTL signal is connected, activate Remote Events through WINDAQ Acquisition Software.
Events may be automatically placed on the rising or falling edge of the trigger signal. Use the menu command
Options > Remote Events + to set WINDAQ to place event markers on low-to-high transitions of the Event input.
Use the menu command Options > Remote Events - to set WINDAQ to place event markers on high-to-low transi-
tions of the Event input.
Event markers may also be placed in your data file manually by pressing the push button on the DI-1110 Instrument.
You must enable Remote Events in WINDAQ to use the button (use the menu command Options > Remote Events
+or Options > Remote Events -).
An example event marker in a WINDAQ data file is shown below.
*Please Note: Event Markers do not display in the real-time WINDAQ acquisition software - they only display in the
WINDAQ playback software (WWB).
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
12
WINDAQ Remote Storage (Rcrd/D1)
To use a switch closure or TTL signal to begin recording data remotely, connect signal leads to the appropriate
Remote Control Record terminals on the DI-1110 as shown below.
Once the switch closure or TTL signal is connected, activate Remote Storage (Record) through WINDAQ Acquisition
Software. Storage to Disk may be automatically placed on the rising or falling edge of the trigger signal. Use the
menu command Options > Remote Storage 1 to set WINDAQ to begin recording on low-to-high transitions of the
Record input. Use the menu command Options > Remote Storage 0 to set WINDAQ to begin recording on high-to-
low transitions of the Record input.
WINDAQ Rate (Rate/D2)
Enable channel 10 to record Rate, or the number of falling-edge transitions per unit of time that are applied to this
input. Click on Edit > Channels in the WINDAQ Acquisition menu to open the Channel Selection grid. Channel 10 is
Signal + Signal -
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
13
the designated Rate channel. Click on the Channel 10 channel box to enable/disable Rates. The Channel 10 channel
box will display an “R” when enabled.
Connect any TTL pulse stream (25 VDC max) to the D2 Rate channel on the DI-1110.
Select Channel 10 in the channel display, then select Edit > Channel Settings in the menu to specify a full scale
range for the Rate channel. Ranges of 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000, and 50000 Hz are
available. Choose a range that comes closest to your expected full scale rate or frequency. For example, if you need to
measure the output of a flow meter that can measure a maximum flow rate of 100 gallons per minute, and the output
frequency at that rate is 100 Hz, you would choose the 100 Hz range setting. A range setting of 200 Hz full scale sac-
Signal + Signal -
www.dataq.com
+-+-
+-
+-
D5D4 D6 GnD+5V
Power
Remote
Active
-
+
Ch1
-
+
Ch2
-
+
Ch3
-
+
Ch4
Model DI-1110
Analog Inputs (±10 VFS, ±100 V max)
+-+-
+-
+-
Digital Ports (25 V @ 100mA max.)
Data Acquisition Starter Kit
Download software
at run.dataq.com
Rate/D2 Cnt/D3Rcrd/D1Evnt/D0
-
+
Ch5
-
+
Ch6
-
+
Ch4
-
+
Ch7
-
+
Ch8

DI-1110 Hardware Manual
Controls, Indicators, and Connections
14
rifices half of the instrument's resolution at 200 gallons per minute, and a range of 50 Hz allows measurements to
only 50 gallons per minute full scale.
Check the "Cycles/min" box to display and select frequencies reported in cycles per minute instead of cycles per sec-
ond (the measurement interval remains the same). Tachometer measurements in units of RPM (revolutions per min-
ute) is just one example that benefits from selecting this option. For example, if the 100 Hz range setting is selected
and "Cycles/min" is checked, the full scale range is actually 6000 cycles per minute.
Please Note: To measure the maximum rate, which is defined as 2 times the Maximum Sample Rate/Channel , the
current values of Maximum Sample Rate/Channel divided by Sample Rate per Channel MUST be an integer.
WINDAQ Counter (Cnt/D3)
Enable channel 11 to record Counts, or the number of falling-edge transitions that are applied to this input. The count
may be reset via WINDAQ software or under program control as necessary. Click on Edit > Channels in the WINDAQ