SR21 SERIES
INSTRUCTION MANUAL
Slot sensor
CONTROL PANEL
AUTO SET PUSHBUTTON:
automatic setting
BI-COLOUR LED
GREEN (READY): operative state indicator
RED (ERROR): error indicator
LED YELLOW (OUT):
output state indicator
DIMENSIONS
LOCK SCREW
2
12
9 920
6
50
4
26
18
4
97.5
M8
7.5
90
7.5
18
n°2 M4x8
Ø4.25
8
20
26
16
mm
NOTE
To install the sensor with 90° connector, unscrew the lock screw and
rotate the block counterclock-wise, when finished tighten the lock
screw completely.
CONNECTIONS
M8 Connector
10 … 30 Vdc
+-
PNP
0 V
2
1
4
3
NPN
(WHITE)
(BROWN) (BLUE)
(BLACK)
(
the connector is viewed from
the external side of the housing)
TECHNICAL DATA
Power supply: 10 … 30 Vdc; protected
against inversion of polarity
Ripple: 2 Vpp max.
Consumption
(output current excluded): 55 mA max.
Output: NPN and PNP on different pins;
pull up/down resistance = 10KΩ
Output current: 100 mA max.
with short-circuit protection
Saturation voltage: 1 V max. with NPN
2 V max. with PNP
(values at peak output current)
Response time: 66 µs max. (SR21-AH/AR/AV)
33 µs max. (SR21-AS)
Switching frequency: 7.5 kHz max. (SR21-AH/AR/AV)
15 kHz max. (SR21-AS)
T rise: 1 µs (NPN; R = 1 KΩ)
120 µs (NPN; C = 4,7 nF)
internal pull up 10KΩ
T fall: 1 µs (PNP; R = 1 KΩ)
120 µs (PNP; C = 4,7 nF)
internal pull down 10KΩ
Humidity: 35 … 85% rH non condensing
Indicators: Bi-colour LED READY/ERROR
(green/red)
OUT LED (yellow)
Keyboard: AUTO SET pushbutton
Retention data: EEPROM non-volatile memory
Operating temperature: 0 … 55°C
Storage temperature: -20 … 70°C
Electrical shock protection: Class 1
Emission frequency: 20 Khz ±10% modulated light
Emission type: 880 nm infrared (SR21-AR/AV/AS)
red/green visible (SR21-AH)
Ambient light rejection: according to EN 60947-5-2
Slot width: 2 mm
Detectable object limits: max. thickness 1.5mm
min. width 1mm (SR21-AH/AR)
min. width 0.5mm (SR21-AV/AS)
Housing material: ZAMA
Lens material: Glass
Protection class: IP65
Connections: M8 4 pole connector
Weight: 115 g.
SETTING
Sensor setting
1) Place the label or the mark to read in the sensor slot using the
reference marks on the tip for alignment.
2) Press and hold the AUTO SET pushbutton till the green READY LED
turns OFF, this starts the acquisition phase of the object to read
which must not be removed till the green LED lights on again.
3) When the green READY LED blinks, put the label support or the
mark background in the sensor slot using the reference marks on the
tip for alignment.
4) Press and hold the AUTO SET pushbutton till green READY LED
turns OFF, this starts the acquisition phase of the object to read
which must not be removed till the green LED blinks.
5) The green READY LED continuously ON indicates the setting is
completed and the sensor is ready.
Error messages
•Alternate blinking of the green READY LED and the red ERROR
LED indicates that the contrast between the label/support or
mark/background is insufficient, or that the setting is incorrect.
Repeat the sensor setting operation.
•The red ERROR LED blinking indicates the output is in protection
mode because of a short circuit. As soon as the cause of the short
circuit is removed, the output reactivates and red LED turns OFF.
•The red ERROR LED continuously ON indicates the sensor is
damaged and must be replaced.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are
conform to the 2004/108 CEE, 2006/25/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective
during the warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements
without prior notification.
826540047 Rev.J
SR21-IR / SR21-RG
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (YELLOW)
The yellow LED ON indicates output activation.
READY/ERROR LED (RED/GREEN)
The green LED continuously ON indicates a normal operating condition. Refer to the “SETTING”
paragraph for the correct setting phase indications.
The red LED continuously ON or blinking indicates an error status.
Refer to “ERROR INDICATIONS” paragraph for the correct indications during the different functioning
phases.
AUTO-SET PUSH-BUTTON
Activates the different setting modes using the READY/ERROR LED indications.
The pressure on the AUTO-SET push-button can be “brief” when pressed for at least 3 sec., or “long”
when pressed longer.
Refer to “SETTING” paragraph for operating mode indications.
DIMENSIONS
mm
16
7.5
n°2 M4x8
12
Ø4.25
90
2
4
418
18
6
M8
LOCK SCREW
50
7.5
9 9
20
826
20
97.5
26
POWER SUPPLY
OUTPUT
PUSH-BUTTON
LEDS
NOTE
To install the sensor using the connector positioned at 90°, unscrew the blocking screw and rotate the
fixing block in an anti-clockwise direction. At the end rescrew the blocking screw.
CONNECTIONS
M8 connector
TECHNICAL DATA
Power supply: 10 … 30 Vdc;
reverse polarity protection
Ripple: 2 Vpp max.
Consumption
(output current excluded): 55 mA max.
Outputs: NPN and PNP on different poles;
pull up/down resistance= 33 KΩ
Output current: 100 mA max.
short-circuit protection
Output saturation voltage: 2 V max. with NPN
2 V max. with PNP
(values at maximum output current)
Response time: 20 µs max.
Switching frequency: 25 kHz max.
T rise: 1 µs (NPN; R = 1 KΩ)
120 µs (NPN; C = 4.7 nF)
33 KΩpull-up internal resistance
T fall: 1 µs (PNP; R = 1 KΩ)
120 µs (PNP; C = 4.7 nF)
pull-down internal resistance 33 KΩ
Humidity: 35 … 85% rH non-condensing
Indicators: Bicolour READY/ERROR LED (green/red)
OUT LED (yellow)
Setting: AUTO-SET push-button
Data retention: EEPROM non volatile memory
Operating temperature: -20 … 60°C
Storage temperature: -20 … 70°C
Emssion frequency: Modulated light at 50 kHz ±10%
Emission type: infrared 880 nm
visible red/green (633 nm/570 nm)
Ambient light rejection: EN 60947-5-2
Slot width: 2 mm
Detectable object limits: Min. 0.5mm width
Housing material: ZAMA
Lens material: glass
Mechanical protection: IP65
Connections: M8 4-pole connector
Weight: 115 g.
SETTING
Static setting (MANUAL)
Recommended in presence of transparent irregular profiles and requires a separate acquisition of the
label and of the support with manual positioning.
The best result is obtained acquiring the most transparent area of the label and the most opaque area of
the support.
Setting steps:
1) With LED continuously ON, position the label in the sensor slot if the output has to be activated in
correspondence of the label (NORMAL output), or position the support if the output has to be
activated in correspondence of the support (INVERTED output). Use the specific references for
centring.
2) Briefly press AUTO-SET. The green and yellow LEDs turn OFF. The object acquisition phase begins.
The object must not be moved until the green LED doesn’t blink rapidly.
3) When the green LED blinks postion the second object (support or label) in the sensor slot using the
specific references for centring.
4) Briefly press AUTO-SET. The green LED turns OFF. The detection of the second object begins. The
object must not be moved until the green LED doesn’t turn ON continuously.
5) The green READY LED continuously ON indicates that the sensor has detected a sufficient contrast
between the label and the support. The sensor can function with the new setting. A different indication
signals an error due to insufficient contrast.
Static setting of only the support (MANUAL)
Recommended in presence of less critical conditions where the label is totally opaque and the output
has to be activated in correspondence of the label. The detection of only the support has be carried-out
with manual positioning.
Setting steps:
1) With LED continuously ON, position the support in the sensor slot, slot using the specific references
for centring.
2) Briefly press AUTO-SET. The green and yellow LEDs turn OFF. The support acquisition phase
begins. The support must not be moved until the green LED doesn’t blink rapidly
3) When the green LED blinks, press AUTO-SET until the green LED blinks rapidly three times. Release
the push-button.
4) The green READY LED continuously ON indicates that the sensor has detected a sufficient support
transparency degree. The sensor can function with the new setting, activating the output in
correspondence of the label (NORMAL output). A different indication signals an error due to insuffient
transparency.
Dynamic setting with NORMAL or INVERTED output
The programming has to be carried-out during normal movement of the label ribbon inside the sensor
slot. Recommended for labels and supports with a rather uniform transparency degree.
Setting steps:
1) With green LED continuously ON, start the movement of the label ribbon in the sensor slot.
2) Press AUTO-SET until the green LED blink slowly.
3) Release the push-button. The sensor acquires the transparency degree of both the moving labels and
support in approximately 2 sec. cycles. Leave the sensor in this acquisition phase for the time
necessary to guarantee the detection of the major number of points possible. The duration depends
on the ribbon speed and dimensions of the labels and support.
4) Setting with NORMAL output: briefly press AUTO-SET. The green READY LED continuously ON
indicates that the sensor has detected a sufficient contrast between the label and support. The sensor
begins to function with the new setting and the output is activated in correspondence of the label. A
different indication signals an error due to insufficient contrast.
5) Setting with INVERTED output: press AUTO-SET until the green LED blinks rapidly three times.
Release the pus-button. The green READY LED continuously ON indicates that the sensor has
detected a sufficient contrast between the label and the support. The sensor begins to function wth
the new setting and the output is activated in correspondence of the support. A different indication
signals an error due to insufficient contrast.
ERROR INDICATIONS
READY/ERROR LED blinking with slow red and green alternation: indicates that the setting (static or
dynamic) has failed due to insufficient transparency or contrast between label and support. In this case
the sensor maintains the previous setting and returns to normal functioning pressing and releasing
AUTO-SET.
READY/ERROR LED red blinking at average speed: during normal functioning and only with active
output, indicates a short-circuit or overload of the outputs or insufficient power supply. The indication
disappears when the cause is removed.
PUSH-BUTTON BLOCKING AND UNBLOCKING
The push-button can be blocked to avoid accidental movements during normal sensor functioning. The
block can be maintained even after the turning OFF and turning ON of the sensor. The blocking and
unblocking operations are given below:
1) With sensor turned OFF press AUTO-SET
2) Re-power sensor keeping the push-button pressed. The sensor inverts the block status: if the push-
button was unblocked the bock is activated and the red LED is continuously ON, if the push-button
was blocked the sensor unblocks it and at sensor re-powering the green LED is continuously ON.
3) The sensor begins to operate with normal functioning. The setting can not be modified if the push-
button is blocked.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the 2004/108 CEE,
2006/25/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty
period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826003050 Rev.A

This manual suits for next models

2

Other Datasensor Accessories manuals

Datasensor TL80 Series User manual

Datasensor

Datasensor TL80 Series User manual

Datasensor TL80 Series User manual

Datasensor

Datasensor TL80 Series User manual

Datasensor S62 B Series User manual

Datasensor

Datasensor S62 B Series User manual

Datasensor SVS1 User manual

Datasensor

Datasensor SVS1 User manual

Datasensor S65-PA-5-Z User manual

Datasensor

Datasensor S65-PA-5-Z User manual

Datasensor TL46-W User manual

Datasensor

Datasensor TL46-W User manual

Popular Accessories manuals by other brands

XMOS Audio Interface quick start guide

XMOS

XMOS Audio Interface quick start guide

quadient AS-CSD6 user guide

quadient

quadient AS-CSD6 user guide

Axis AXDL-100 Manual guide

Axis

Axis AXDL-100 Manual guide

TOPPOINT LT95081 quick start guide

TOPPOINT

TOPPOINT LT95081 quick start guide

Flextailgear MAX COOLER user manual

Flextailgear

Flextailgear MAX COOLER user manual

LaserPoint Fit IPL-R instruction manual

LaserPoint

LaserPoint Fit IPL-R instruction manual

Elko Inels RFDSC-71 manual

Elko

Elko Inels RFDSC-71 manual

VonHaus 2500456 quick start guide

VonHaus

VonHaus 2500456 quick start guide

Comet P8552 quick start guide

Comet

Comet P8552 quick start guide

OPP Liam 21222KF-UK Product description

OPP

OPP Liam 21222KF-UK Product description

Interlogix ADC-IS-300-LP installation guide

Interlogix

Interlogix ADC-IS-300-LP installation guide

PCB Piezotronics 354C02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 354C02 Installation and operating manual

Comet XRC-4501-OW manual

Comet

Comet XRC-4501-OW manual

Halsey Taylor HTVBLEE-MVP Series owner's manual

Halsey Taylor

Halsey Taylor HTVBLEE-MVP Series owner's manual

VWR INCU-Line IL 23R Cool Short instruction manual

VWR

VWR INCU-Line IL 23R Cool Short instruction manual

WIKA D-20-9 operating instructions

WIKA

WIKA D-20-9 operating instructions

Monnit MNS2-9-W2-OC-ST user guide

Monnit

Monnit MNS2-9-W2-OC-ST user guide

CMA Dishmachines DIFFERENTIALVOLTAGE SENSOR 0210I user guide

CMA Dishmachines

CMA Dishmachines DIFFERENTIALVOLTAGE SENSOR 0210I user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.