DATEQ BV
Bank: IBAN NL 88 RABO 0301019444
e Paal 37, 1351 JG Almere – Holland
Internet: www.dateq.nl
Bank swift RABO NL2U
Tel.: +31 36 5472222 Fax: +31 36 5317776
Skype: dateq_audio
Chamber of commerce no: 39031467
Operation
DATEQ SPL-D2 Manual
Display connected to the SPL5
When the displa is linked to the SPL5 the microphone values will be downloaded from the SPL5
automaticall . Those values will be showed in the large displa .
The LED-bar functions as a VU-meter, the displa gives the actual SPL.
As soon as the sound-level exceeds the pre-set threshold the LED's will light up red.
Connecting to the SPL5
The displa unit is connected to the SPL with the jack connector. A standard microphone cable
can be used. Connect the shield to the jacks' ground pin and the signal wires to the tip. At the SPL5
the shielding can be connected to pin 14, and the signal wire to pin 8 of the DB-25 connector.
Using the display stand-alone
To use the displa as a stand-alone device the
microphone has to be connected. The audio-
level will be showed in the large LED displa .
By means of the PC-software the threshold can
be adjusted. When the audio-level exceeds this
level the LED s will become red. This can be
used as a warning for the live-band, or the disk-
jockey.
The displa units hold three correction-curves:
• ANSI-A
• ANSI-B
• ANSI-C
The measured values can be adjusted to match
a calibrated meter. B moving the slider to the
right the microphone becomes more sensitive.
Moving the slider
to the left gives a higher level.
Common settings
The displa can be dimmed automaticall in a dark environment. This function can be enabled b
selecting 'Auto ambient light correction’
The intensit of the ‘numbers and the Vu meter can be adjusted with the sliders as can be the
response time of the Vu meter.