deconta R 150 silent User guide

Original instruction manual
Luftreiniger R 150 silent


Änderungsindex
Revision 0 Original instruction manual
Luftreiniger R 150 silent
1 / 53
Änderungsindex
Date Rev. Amendment / Reason for amendment /
Consequence of amendment / Comment In-charge
13.11.2020 0 New publication Uwe Schaaf
This instruction manual was first produced on behalf of (2020-2968) uttc – Ingenieur-
It has been prepared to the best of our knowledge and all amendments to the original
version are included here.
If you discover an error or find the instructions ambiguous, please inform us about the
same. We would appreciate customer feedback as this helps improve our overall cus-
tomer satisfaction.
Please get in touch with:
deconta GmbH
Im Geer 20
46419 Isselburg
Tel.: +49 287491 91560
Fax: +49 2874 915611
Internet: www.deconta.com
This instruction manual must be kept with the of product appliance at all times.
A copy of this instruction must also be supplied when selling this appliance.


Table of contents
Revision 0 Original instruction manual
Luftreiniger R 150 silent
3 / 53
Table of contents
1Information on reading...................................................5
1.1Abbreviations, synonyms, signs..............................................................5
1.2Risk reduction through user information..................................................5
2Legal regulations............................................................9
2.1Exclusion of liability..................................................................................9
2.2Existing directives....................................................................................9
3Safety........................................................................9
3.1Intended use............................................................................................9
3.2Gerät......................................................................................................11
3.2.1Power switch..........................................................................................11
3.2.2Labels on the applianceem Gerät..........................................................11
3.2.3Protective conductor, earthing and equipotential bonding ....................12
3.3Safety instructions .................................................................................12
3.3.1According to the source of the hazard...................................................12
3.3.2After the operation phase ......................................................................14
3.3.3According to the location of the hazard .................................................16
4Appliance description..................................................18
4.1Scope of delivery...................................................................................18
4.2Technical data .......................................................................................18
4.3Order numbers - replacement filter / UV lamp (if installed)...................20
4.3.1Filter description/classification...............................................................23
4.4Electrical connection..............................................................................24
4.5Operating and indicating elements........................................................24
5Transport.......................................................................26
5.1Warnings................................................................................................26
5.1.1Mains cable............................................................................................26
6Assembly.......................................................................26
7Initial operation.............................................................28
7.1Warnings................................................................................................28
7.1.1Mains cable............................................................................................28
7.1.2Unsuitable mains voltage.......................................................................28

Table of contents
4 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
8Operation and control ..................................................30
8.1Warnings...............................................................................................30
8.1.1Mains cable...........................................................................................30
8.1.2UV lamp (if installed).............................................................................30
8.1.3UV lamp (if installed).............................................................................30
8.2Operating modes...................................................................................31
8.2.1Manual mode ........................................................................................31
8.2.2Automatic mode....................................................................................32
8.2.3Setting the UV lamps (if installed) in automatic mode..........................34
8.3Settings - Filter change intervals...........................................................35
8.4System settings..................................................................................... 36
8.4.1Display brightness.................................................................................37
8.4.2Factory Reset........................................................................................ 37
8.5Sleep mode...........................................................................................38
8.6Key switch option.................................................................................. 39
9Filter change..................................................................40
9.1Warnings...............................................................................................40
9.1.1Voltage-carrying appliance parts .......................................................... 40
9.1.2UV lamp (if installed).............................................................................40
9.1.3Cover..................................................................................................... 40
9.2Change of pre-filter, UV lamps and large HEPA filter........................... 42
9.3Changing the optional activated carbon mat ........................................ 44
9.4Change of activated carbon cell and HEPA filter - small
(optional)............................................................................................... 45
10Cleaning.........................................................................48
10.1Warnings...............................................................................................48
10.1.1Voltage-carrying appliance parts .......................................................... 48
11Disposal of appliances.................................................49
12Systems for documentation.........................................50
12.1Type plate ............................................................................................. 50
12.2EC/EU declaration of conformity pursuant to the low-voltage
directive 2014/35/EU............................................................................. 51

Information on reading
Abbreviations, synonyms, signs
Revision 0 Original instruction manual
Luftreiniger R 150 silent
5 / 53
1 Information on reading
1.1 Abbreviations, synonyms, signs
Abbreviation/
Synonym Meaning
PSA Personal protective equipment (PPE)
EMV Electromagnetic compatibility (EMC)
BetrSichV Ordinance on Industrial Safety and Health
DGUV German Social Accident Insurance
Gerät Luftreiniger R 150 silent
ICNIRP International Commission on Non-Ionizing Radiation Protection
Signs Meaning
Guide to actions
Enumeration
Request to read other documents
Italic Name of a button, push-button, switch
1.2 Risk reduction through user information
According to § 3 of the law concerning liability for defective products (ProdHaftG), a
product is defective “if it does not offer the safety which a person is entitled to expect,
taking all circumstances into account, including the presentation of the product, the
use to which it could reasonably be expected to be put and the time it was put into cir-
culation”.
User information in the form of a manual or instruction manual is part of the presenta-
tion of a product. It must contain all relevant information for safe use throughout the
entire service life of the product. This includes the intended use and foreseeable mis-
use as well as emergency measures.
The directives, standards and regulations that apply to the product may contain re-
quirements for the content of user information.
Directives, standards and regulations other than any C standards are, for example:
2006/42/EC Machinery Directive, Attachment I, Chapter 1.7.4
EN ISO 12100 - Safety of machinery - General principles for design - Risk assess-
ment and risk reduction
EN 82079-1 - Preparation of instructions for use - Structuring, content and presen-
tation - Part 1: General principles and detailed requirements

Information on reading
Risk reduction through user information
6 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
Chapter Safety
The chapter provides information on the measures for your safety. The information
ought to build awareness for safe actions. The objective is to provide a base for train-
ings and briefings.
Information on remaining risks
Safe use also includes knowledge about existing remaining risks. Possible residual
risks that may still be present after the completion of risk reduction must be clearly in-
dicated in an instruction book or handbook. The EN 82079-1 standard specifies the
content and form of presentation of residual risks. For the description of residual risks,
a distinction is made between three hazard levels, which are visualised with signal
words and assigned symbols.
The safety-related information explains the hazards onem Gerät the appliance and
how to avoid these hazards.
Please read the safety-related information carefully. Your expertise will help you to
identify dangerous situations and to protect yourself and others.
SIGNAL WORD Degree of risk
of the hazard Meaning
HAZARD high Death, grievous bodily injury will occur if
the hazard is not avoided.
WARNING medium Death, grievous bodily injury may occur if
the hazard is not avoided.
CAUTION low Minor or moderate injury may occur if the
hazard is not avoided.
Information
not safety-
relevant General information as well as user tips
and work recommendations for efficient
and trouble-free operation.

Information on reading
Risk reduction through user information
Revision 0 Original instruction manual
Luftreiniger R 150 silent
7 / 53
Warning
SIGNAL WORD
This warning text identifies the source of the hazard and the area of effectiveness.
This warning text indicates the consequences.
This instruction states the remedy (possibilities for avoidance etc.).
This instruction manual contains warnings in several chapters. A warning always
warns you against imminent danger. It should be read in conjunction with the situation
in which the warning is given. The objective is to avoid accidents and damages.
Additional information
Information
This indication text provides further information from the risk assessment.
This warning text indicates the consequences.
This instruction states the remedy (possibilities for avoidance etc.).
This instruction manual may contain additional indications in several chapters. These
indications must only be understood in context.


Legal regulations
Exclusion of liability
Revision 0 Original instruction manual
Luftreiniger R 150 silent
9 / 53
2 Legal regulations
2.1 Exclusion of liability
In the event of misuse, incorrect operation or improper repair, no liability is accepted
for any damage. Guarantee services are also excluded in such cases.
2.2 Existing directives
Refer to the EC Declaration of Conformity in chapter 1212.
3 Safety
3.1 Intended use
The air purifier is designed to specifically improve air quality in medical, public, com-
mercial and residential areas (including medical clinics, hospitals, retirement homes,
offices, restaurants).
In the basic version, filtration is carried out via a 3-stage filter system consisting of a
pre-filter, a filter for suspended matter (HEPA filter) and a switchable UV-C lamp (if in-
stalled).
Optionally, the appliance can be equipped with an activated carbon mat or with a larg-
er activated carbon cassette filter with downstream HEPA filter to remove odours from
the room air.
The user must comply with the specified operating parameters of this manual. The
appliance may only be used according to its intended use. Any other use beyond this
is not considered as intended use. The user is liable for any resulting damages or inju-
ries of any kind whatsoever.
The applianceas Gerät may:
be used only for commercial and private purposes,
only be operated indoors, i.e. in a building,
not be operated outdoors,
not be used in potentially explosive surroundings.
The applianceas Gerät is built according to the state of the art and the recognised
safety rules.
Yet, improper or unintended use of the appliancees Gerätes may lead to hazards to
life and limb of the user or of third parties or it may lead to damages to the machine
and other tangible assets.
The application area of appliancees Gerätes is the residential and commercial sector.

Safety
Intended use
10 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
The intended use covers the compliance with this instruction manual as well as in-
struction manuals of suppliers and the compliance with the inspection and mainte-
nance requirements of the suppliers.
The manufacturer shall not be liable for non-compliance and for any resulting damag-
es. The risk shall be borne by the operator.
If there are faults during operation:
Switch off the applianceas Gerät immediately,
Inform the specialised staff or the suppliers.
Reasonably foreseeable misuse
Every use other than the one described in this instruction manual shall be deemed as
a reasonable foreseeable misuse.
This includes:
operation in potentially explosive surroundings,
operation without sheet metal cladding or protective housing,
the mechanical or electrical bypassing of the appliancees Gerätes or appliance
Geräteparts,
the use of parts other than the original parts or parts outside the specification of the
replaced part,
modifications, changes and manipulations,
the non-compliance of instructions and specified operation, maintenance and re-
pair requirements,
the non-compliance with rules and regulations in the country of use and the statu-
tory regulations and accident prevention regulations when dealing with the appli-
anceem Gerät,
the operation of the appliancees Gerätes outside technical data.

Safety
Gerät
Revision 0 Original instruction manual
Luftreiniger R 150 silent
11 / 53
3.2 Gerät
3.2.1 Power switch
Abb. 1 Power switch
The power switch of the appliance is located underneath the power socket. When not
in use, the appliance must be switched off or disconnected from the power supply sys-
tem.
3.2.2 Labels on the applianceem Gerät
Safety-related information is attached to the applianceem Gerät in the form of picto-
grams and/or labels. They indicate risks, which:
occur frequently and/or
have serious consequences.
The following labels are attached to the applianceem Gerät:
Meaning Location Label
Warning against dangerous
electrical voltage Connection socket for the
supply cable
Warning against UV
radiation UV lamps (if installed)

Safety
Safety instructions
12 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
3.2.3 Protective conductor, earthing and equipotential bonding
The following is installed on the appliance:em Gerät
Description Function Pictogram
Protective
conductor Protects people from electric shock.
3.3 Safety instructions
In this chapter, you will find safety-related information to prevent hazards related to the
appliance.as Gerät Compliance with the safety instructions protects the user of the
Gerätappliance, living beings and the environment from damage.
The safety instructions are sorted according to their area of application.
3.3.1 According to the source of the hazard
Applies in all phases of life for the entire appliance.as Gerät
Power
Electrical energy
The supply voltage of the applianceem Gerät is 230 V. Touching live parts leads to fa-
tal electric shock.
Before performing filter change, switch off the power switch and disconnect the
supply cable from the supply cable to prevent it from being switched on again.
Replace the damaged supply cable immediately.
UVC radiation
UV lamps (if installed)
UV radiation, direct or indirect, is harmful to health and can cause damage to eyes
and skin.
There is no danger during proper operation.
When working on the UV lamps, pull the mains plug! If the mains plug is not
unplugged, the lamps switch off automatically as soon as you tilt the appliance or
remove the cover.
To make it more difficult to remove the pre-filter improperly, an optional protective
grille can be fitted. Note that this reduces the volume flow minimally.
The following measured value for UVC radiation was determined with proper operation
and built-in pre-filter:

Safety
Safety instructions
Revision 0 Original instruction manual
Luftreiniger R 150 silent
13 / 53
Measured irradiance, distance of 0.2 m from appliance and floor = 0.001µW/cm2
Limit value for irradiance according to ICNIRP recommendation and directive
2006/25/EC = 0.1µW/cm2
Substances, materials
Ozone (if UV-C lamps are installed)
UV lamps are installed on the appliance.em Gerät During the first approx. 100 burning
hours, there is little ozone formation, which then comes to a complete standstill.
Ozone is an irritant gas that is not dangerous in small doses. Ozone, in combination
with cigarette smoke, can produce harmful decay products. It has a very strong inher-
ent odour, which however dissipates quickly after switching off.
Even if there is no direct health hazard from ozone, we recommend ventilating the
room during the first 100 operating hours.
Mercury (if UV-C lamps are installed)
The mercury contained in UV lamps can be released when the lamp breaks. Mercury
is harmful to the health of all living beings!
Ventilate the room for at least 30 minutes.
Remove the splinters and broken fragments with gloves only.
Do not use a vacuum cleaner.
Place the splinters and broken fragments in a sealable plastic bag.
Take the splinters and broken fragments to a collection station.
Aging, wear and tear
Unnoticeable wear and tear
The applianceas Gerät and its safety equipment are subject to aging. The components
have been designed according to the expected loads. Despite this, they age and wear
out. Components can become defective earlier than expected. If ageing, wear and de-
fective parts are not identified, it may lead to severe injuries.
Follow the filter change intervals.
Perform regular visual inspections.
Human error
Connect the appliance only to 220 - 240 volts alternating current.
The appliance must never come into contact with water during cleaning.
Do not cover the air intake and outlet nozzles during operation.
Switch off the appliance with the power switch during longer interruptions.
Remove spilled substances immediately.

Safety
Safety instructions
14 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
3.3.2 After the operation phase
Applies in special phases of life for the entire appliance.as Gerät
Transport
Power connections
The applianceas Gerät is connected to the power supply system via the house con-
nection. Cables and wires can be damaged even with a minor change in the location.
Cable damage can cause metal parts to become live. Cables can break off and be ex-
posed. An electric shock is possible.
Disconnect the applianceas Gerät from the energy sources before every transport.
Assembly
Positioning
The appliance is delivered as ready for operation ex works and is intended for imme-
diate commissioning. Installation is therefore not necessary.
Do not operate the appliance if there is visible damage. Please get in touch with
deconta GmbH immediately.
When setting up the appliance, please ensure that the surface is even and stable.
Initial operation
First intended use
Connect the appliance only to 220 - 240 volts alternating current.
Switch the appliance on at the power switch on the power socket.
Check the touch screen by tapping on the image of the air purifier.
The appliance starts in manual mode and is immediately ready for operation.
Operation, handling
Display
The appliance is operated via a display. Only very little pressure is needed to tap on
one of the buttons.
Do not touch the display with sharp objects.

Safety
Safety instructions
Revision 0 Original instruction manual
Luftreiniger R 150 silent
15 / 53
Repair and maintenance work
Filter change
The various filters of the appliancees Gerätes are compatible in their parameters and
in their construction. Replacing them with unsuitable filters may result in malfunction
and danger to persons using the appliance.em Gerät
Use only original spare parts or spare parts that meet the specification of the
original spare part.
Repairs may only be carried out by a qualified electrician.
Disposal
Avoid environmental damages
This symbol on the product, operation manual or packaging indicates that this product
should not be disposed of with normal household waste at the end of its life.
It must be sent to a collection point for the recycling of electrical and electronic
appliances.
Please contact your local authority to find out which disposal centre is responsible.
The materials are recyclable according to their identification. With the proper supply of
old appliance for recycling, material recovery or other forms of recovery, they make an
important contribution to protecting our environment.
Information
The disposal of used filters may be subject to certain regulations or laws if they
filter harmful substances.
Filters must be disposed of in accordance with legal regulations.

Safety
Safety instructions
16 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
3.3.3 According to the location of the hazard
Applicable for special appliance Geräteparts in all phases of life
Supply cable of the appliance
Electric shock due to defective supply cable
Touching a defective supply cable may result in death or serious injury.
Do not damage the supply cable (e.g. by vehicle overrun, tearing, squeezing).
Regularly check the supply cable for damage.
Have defective supply cable replaced before use by the deconta service or a
qualified electrician."


Appliance description
Scope of delivery
18 / 53 Original instruction manual
Luftreiniger R 150 silent Revision 0
4 Appliance description
4.1 Scope of delivery
The following is included in the scope of delivery of an air purifier, regardless of whether an ap-
pliance was purchased or rented, unless agreed otherwise:
Air purifier
HEPA filter (already installed in the appliance)
Pre-filter (already installed in the appliance)
2 UV-C lamps (if installed)
Mains cable
4 steering rollers with fixing material
Filter certificate
Certificate of appliance test
Instruction manual
4.2 Technical data
All data on air performance and volume flows are taking into account a measuring tolerance of ±
15% based on the measuring range end value, determined in a multi-point measuring method
with a calibrated vane anemometer.
Dimensions and weights of the appliancees Gerätes
Description Value
ApplianceGerät L x W x H 393 mm x 463 mm x 950 mm
Weight with large HEPA filter and pre-
filter 22.0 kg
Weight with large HEPA filter, pre-filter
and activated carbon filter 23.5 kg
Weight with large HEPA filter, pre-filter,
activated carbon filter and small HEPA
filter
34.5 kg
Performance data
Description Value
Mains connection 230 V / 50 Hz
Performance 220 W
Standby 1.3 W
Protection type IP 20
Mains input fuse 2 A
Table of contents
Popular Air Cleaner manuals by other brands

Boneco
Boneco Therapure TP150 manual

Pure n Natural Systems
Pure n Natural Systems LA-1000-FM Installation manual and user's guide

Electrolux
Electrolux EL500 Series owner's guide

Sharp
Sharp FP-P35CX - HEPA Air Purifier Operation manual

Honeywell
Honeywell HEPACLEAN HHT270 Series manual

Philips
Philips AC3858/86 user manual

Flanders
Flanders Bolt Lock HEPA Filter Housing Surelock B Specification sheet

Airpura
Airpura H600 Operating & Filter Replacement Directions

Momax
Momax Ultra-Air Plus instruction manual

Blaupunkt
Blaupunkt BAP-IT-H3148-U31W instruction manual

Camozzi
Camozzi MX Series operating instructions

Honeywell
Honeywell 60001 - Enviracaire Grade Air Purifier owner's manual