Dear customer,
you have purchased a Roters air purifier from the XG 500, XG 520 or XG 820 series and have therefore decided on a,
Made in Germany” high-quality product. Regularly exchanging the filter cartridges is necessary in order to maintain the
filter performance. Always control the filter cartridges every 6 months or after the red filter interval indicator illuminates.
These instructions explain the necessary steps for exchanging the filter cartridges.
Device feet
Clamping screws for filter unit
4 pieces)
Inspection cover
Intake shutter (only with Profi model)
Intake opening
H14 HEPA Filter
Activated carbon filter/gas filter
Pre-filter
Filter exchange instructions
Air Purifier Series XG 500/520/820
Always observe before exchanging the filter!
Always switch off the air purifier and disconnect the mains plug before exchanging the filter. Lay the air purifier with the front
side positioned on a soft sub-surface.
Wear a protective mask (FFP2) and disposable gloves when exchanging the filter. Never execute a filter exchange in a
hygiene area.
Please handle the filter cartridges with care. Even the smallest damage can impair the effectiveness of the filter. Never
remove the enclosed test certificate when inserting the HEPA H14 filter cartridge.
All electrical components must not be cleaned with water or solvent-containing cleaning agents. These can ingress into the
electrical components as well as the wiring, dissolve them and thereby cause an electric shock.
The air purifier must never be operated with loosened or missing screws on the inspection cover or without an inserted filter.
Additional information can be found in the operating instructions for the air purifier.
Bottom side/rear side with opened inspection cover
Serie XG 500/520/820 | EN
Filter Exchange Instructions | 2021B
Telephone: +49 (0) 21 51
|
74 30 11
Telefax: +49 (0) 21 51
|
74 30 12 Web: www.roters.gmbh
Email: info@roters.gmbh
Tempelsweg 32a
47918 Tönisvorst, Germany
© Copyright ROTERS GmbH | Technical alterations, errors, printing errors reserved.
Filter exchange in detail The figures show the XG 500 Basic/Design device without intake shutter
Loosen the four clamping screws on the bottom of the
device with an Allen key. Screw out the screws by
approx. 35 mm.
Lay all the filter cartridges in a disposal sack and clean
the air purifier housing.
Loosen the four inspection cover screws on the rear side
of the air purifier. Remove the inspection cover.
Insert the new filter cartridges. Always observe the
correct arrangement and air direction for the cartridges
when inserting them.
When finished, position the cover and tighten the four
clamping screws and the four inspection cover screws
again. Stand the air purifier up again and execute a test
operation.
Do you still have questions regarding exchanging filters?
Please feel free to contact us at: info@roters.gmbh
Remove the pre-filter from the housing. Then remove the
activated carbon filter/gas filter and the HEPA H14 filter.
Package Article No.
for XG 500 FPX50050 PM Z-Line (pre-filter), Gas filter, HEPA H14
for XG 520 FPX52080 PM1 70% (pre-filter), Gas filter, HEPA H14
for XG 820 FPX82080 PM1 70% (pre-filter), Gas filter, HEPA H14
➊➍
➋➎
➏
➌
Serie XG 500/520/820 | EN
Filter Exchange Instructions | 2021B
Telephone: +49 (0) 21 51
|
74 30 11
Telefax: +49 (0) 21 51
|
74 30 12 Web: www.roters.gmbh
Email: info@roters.gmbh
Tempelsweg 32a
47918 Tönisvorst, Germany

This manual suits for next models

2

Popular Air Cleaner manuals by other brands

Steel City 65120 user manual

Steel City

Steel City 65120 user manual

CFM CX1000 user guide

CFM

CFM CX1000 user guide

Amana Media MAC1 Series installation instructions

Amana

Amana Media MAC1 Series installation instructions

Glaziar PUR50 Instructions for use

Glaziar

Glaziar PUR50 Instructions for use

Panasonic F-PXR40H operating instructions

Panasonic

Panasonic F-PXR40H operating instructions

Lightair IonFlow 50 manual

Lightair

Lightair IonFlow 50 manual

Lennox Healthy Climate PMAC-12C brochure

Lennox

Lennox Healthy Climate PMAC-12C brochure

IKEA UPPÅTVIND quick start guide

IKEA

IKEA UPPÅTVIND quick start guide

Nash AP-1 PureSmart instruction manual

Nash

Nash AP-1 PureSmart instruction manual

Aktobis WDH-220B manual

Aktobis

Aktobis WDH-220B manual

Honeywell HHT-013-HD user guide

Honeywell

Honeywell HHT-013-HD user guide

LG PH-U450 Series owner's manual

LG

LG PH-U450 Series owner's manual

Sharp FU-40SE Operation manual

Sharp

Sharp FU-40SE Operation manual

Philips AC2721 user manual

Philips

Philips AC2721 user manual

Filtrete FAP-T02 manual

Filtrete

Filtrete FAP-T02 manual

DeLonghi DDSX 220WFA manual

DeLonghi

DeLonghi DDSX 220WFA manual

TruSens Z-2000 manual

TruSens

TruSens Z-2000 manual

Motorola MBP87SN quick start guide

Motorola

Motorola MBP87SN quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.