Faton FA330H User manual

Air Purier
USER MANUAL
MODEL: FA330H
Please read the user manual carefuly before use. And please
keep it properly after reading for checking in the future.

2
USER MANUAL
CONTENTS

3
USER MANUAL
1 Safety precautions 4
2 Product introduction 6
Function description of control panel. 7
3 Before use 8
Learning about air quality indicator light 8
Disassembly and installation methods of the back cover 9
Placementofairpurier 9
Installlternet 10
4Puricationprinciple 12
5 How to use 13
Function description of control panel. 13
Turnontheairpurier 13
Manual adjustment of wind speed 14
Timer mode 14
Child-lock function 14
Photosensitive sensor 14
6 Maintenance and cleaning methods 15
Cleantheairpurier 15
Clean air quality sensor 15
Changelter 16
Long term idling 18
Referringtimeforlterreplacement 18
7 Fault handing 19
Warranty and service 20
Order parts or accessories 20
Fittings 20

4
USER MANUAL
Do not touch power plug with wet
hands.
Or else may cause electric shock.
Prohibited to use beyond power
or connected devices beyond
speciedvalue.Onlycanuse
220V-alternating current (AC )
power supply
Overheatingandreaccidentmayoccurifyou
useuniversalsocketordevicesbeyondspecied
value.
No damage to power line and
socket.
Do not bind wires when you use this machine. it
maycauseelectricshock,shortcircuitandre
accident if you use broken wires.
Anycuttingandscratching,retting,overdistor-
ting, twisting, screwing and pulling of lines are all
forbidden. Do not put any heavy product on wires
and sockets.
Do not take apart or modify the
airpurierwithoutauthorization.
Takingapartormodifyingairpurierwithoutau-
thorizationmaycauseelectricshock,alfunction
orreaccident.
Please make sure to turn off the
power before cleaning machine.
Else it may cause machine sudden running and
further electric shock accident.
Please insert the plug complete-
ly into the power socket before
startingtheairpurier.Ifnot,it
may cause electric shock and
overheating,evenreaccident.
Do not use damaged plug or loose power socket.
Regularly clean power plug
If dust accumulating on power plug, the damp-
ness will make damage to insulation
partoftheplug,thuscausingreaccident.
Pull out the power plug and then clean with dry
cloth( do not use wet cloth).
If the machine will be of no use for long time,
please unplug it.
Do not put bars or metal products
nearby air outlet or openings.
Else it may touch the internal parts and get an
electric shock or damage.
1. Safety precautions
In order to avoid possible damage to you, others or
any property, please make sure to pay attention to
the following safety precautions.
If the machine power line is out of order, you must entrust machine manufacturer, main-
tenanceservicecenterorqualiedtechnicianstoreplaceittokeepdangeraway.
WARNING
Wet hand
Forbidden
Unplug!
Forbidden!
Forbidden!
Taking apart
is forbidden!
Forbidden!

5
USER MANUAL
Donotusesolventlikebenzene,
diluent,etc.tocleanairpurier.
keep the machine away from
wasp spray
Orelseairpuriermaybrokeintodamageeven
short circuit occurs which can lead electric shock
orreaccident.
Donotuseairpurierinthesitu-
ation of greasy particle.
For example kitchen which can reduce the service
lifeofairpurierlter.
This machine should not be used as ventilating or
air evacuating equipment.
Donotusetheairpurierinthe
room with fumigation type pestici-
des.
Chemical residue could be accumulated inside
the machine and then release from the outlet,
making harm to health.
The room should keep ventilated thoroughly
after you use insecticide and then start to use air
purier.
Keep machine body dry
Orelseitmaycauseelectricshockorreacci-
dent because of short circuit.
Hold the plug when you take out
the power plug and do not pull
wires which may cause
short circuit or damage to wires
toavoidreaccidentandelectric
shock.
Iftheairpurierworkstogether
with electric heater, the room
should keep ventilation.
Or else there may be carbon monoxide poisoning
accident.
Theairpuriercannotclearoffcarbonmonoxide.
Donotuseairpurierinhigh
temperature, humid conditions
like bath room, as these
situations may cause current
leakage which can lead electric
shockorreaccident.
Keep the machine away from
volatilesubstancesoramma-
ble items such as tobacco and
sparks;
Orelseitmaycausereaccident
ATTENTION
Forbidden!
Forbidden!
Wetting
forbidden!
Keep away
fromame!
Verboden te
plassen!
Notice
Please turn off the power immediately in case of any
of the following situations:
• Malfunction of any swtich;
• Circuit breaker worked or fuse burned
• Anomal heating of wires or plugs
• Any burnt smell, anomal sound or shock
• Any other anomaly or malfunction
Forbidden!

6
2. Product introduction
USER MANUAL
Indicator light of
air quality
Front panel
Air outlet
Air inlet
Handle
Air quality sensor
Control panel
Back cover
HEPAlterandActivatedcarbonlter

7
USER MANUAL
Indicator light of
Child-lock Light hole
Child-lock Timer button Speed button ANION button
ON/OFF button
1 h,2h,4h,8h
Timing indicator
Indicator light of
AUTO mode
Indicator light of
lterreplacement
Indicator light of
ANION
Low
Speed
Medium
Speed
High Speed
Function description of control panel

8
USER MANUAL
3. Before use
Airqualityindicatorreectsthecurrentairqualitycondition.
Indicatorlightscolorofairpurier
Learning about air quality indicator light
Indicator light of air quality
Considering power consumption, air quality
sensor doesn’t work in ready mode.
Hint
Blue Good
Green Ordinary
Red Poor

9
USER MANUAL
Disassembly and installation
methods of the back cover Placement of air purier
1 Disassembly method of the back cover
Press play button in the back cover and
pull the cover, then you can lift the back
cover and pull out slightly.
2 Installation method of the back cover
To reinstall the back cover, please align
atthexedgrooveandinsertthecover
into the groove, making the play button
and frame withhold.
To make sure good air circulation effect,
please ensure there is 50cm distance bet-
ween air inlet and wall or curtain. Besides,
the distance to air outlet is not less than
50cm.
Please keep 1 meter or more distance
from TV, Radio. Please do not use the
same socket with TV, radio and other
applianceswhichcanavoidpictureutter
or noise.
It may make wall surface around machine
body dirty if you place the machine in the
same place for a long time.
Do not obstruct air inlet and outlet, ensu-
ringenoughventilationandhighefciency.

10
USER MANUAL
Information
Alltheltersareequippedwiththepuri-
ertogether,youshouldremoveallthe
packingsofthelterbeforeuse.Please
disassembleltersaccordingtothefollo-
winginstructions,reinstalltheltertoair
purier.
1 Place the machine in a dry, smooth and
atground.
2 Press play button in the back cover and
pull the cover, then you can lift the back
cover and pull out slightly.
3Disassembleallthelters.
Operate in accordance with the following
stepstoensurecorrectlterinstallation
whenyourstusethismachine.
Install lter net
Operation steps
Attention
Hint
Make sure power plug is outage when do
installation, maintenance or transportation
work. Do not use the machine without
lter.Pleaseremoveallpackagesofltes
before use.
Make machine stick close to wall surface
for realiability when you remove or insert
lters.

11
USER MANUAL
4Removeallpackageofthelternets.
5Replaceltersintotheairpurier.
6 To reinstall the back cover, please align
atthexedgrooveandinsertthecover
into the groove, making the play button
and frame withhold.
Hint
Please be careful when install the back
cover, watch your hands.

12
USER MANUAL
4. Purication principle
Thepurieradoptedpassiveadsorption
and active type at the same time. The air
absorbintotheairpurierbymotor.and
throughtheltersandaniongenerator,
thensendoutofpurier.ltcanlterdust.
Remove formaldehyde and eliminate
peculiar smell. And anion generator can
generate air negative ions, also known as
air vitamin.
4stepslterpurication
Firststep:Fibrelter
Secondstep:HighefciencyHEPAlter
Thirdstep:Activatedcarbonlter
Fourth step: Anion generator
Firststep:Fibrelter
InltratethebrelterwithNaturalanti-
bacterial, Anti-allergy elements, can effec-
tively restrain the allergen like pollen.
Function: can effectively restrain the aller-
gen like pollen.
Second step:
HighefciencyHEPAlter
HighefciencyHEPAlterisspecially
focused on particle with dia .bigger than
0.25 micron.
Third step:
Activatedcarbonlter
Can absorb volatile organic compounds
and further remove toxic substances such
as formaldehyde and other peculiar smell.
Fourth step:
Anion generator
Anion generator can produce negative
ions, make the dust,bacteria,spores,pol-
len, dander and other particles charge-
d,then it will be absorbed by integrated
discharge device, it can remove PM2.5.
And anion can also activate oxygen mo-
lecules in the air to form negative oxygen
ion, help human to get fresh air.

13
USER MANUAL
5. How to use
Afterpluggedinthepower,purierwill
sendoutasiren,alltheindicatorwillash
three times . Then, the power light will
ashslowly.
PressON/OFFbutton,purierenters
AUTO mode. The indicator light of AUTO
mode and power light will be on.
Indicator light of air quality will show
greencolourwhenthepurierturnon,
after 2 min’s preheating, it will detect
the air quality automatically.
Function description of control panel
Plug in Turn on the air purier
Hint
Please press ON/OFF button for 5s to turn
off the machine. With a siren the power
lightwillash,thenpulloutthepowerplug.

14
USER MANUAL
Automodus
Manual adjustment of wind speed
Press SPEED button, you can choose
air speed in turn ‘AUTO mode, speed 1,
speed 2 and speed 3’.
Press ANION button, with beeps ,anion
function will work, and the indicator light of
ANION will be on.
PressANIONbuttonagain,thepurierwill
out of anion function, the indicator light of
ANION will be off.
Press the Child-lock button for 3s, with
beeps the indicator light of Child-lock will
beon.Inthiscondition,thepurierwon’t
be action when you press any key (except
Child-lock button).
Under AUTO mode, if the lighting in the
roomisdarktheairpurierwillenter
SLEEP mode. Then all the indicator lights
will be off except the power light. The fan
speed change to low speed.
TIMER mode
Child-lock function
Photosensitive sensor
ANION mode
Press TIMER button, the working hour will
be option circulatory in 1 h,2h ,4h,8h,and
no timer.
UnderAUTOmode,thepurierwillchoose
wind speed automatically according to the
air quality.

15
USER MANUAL
Clean the air purier
Clean the air quality sensor
6. Maintenance and cleaning method
Please make sure to pull out power plug
before cleaning the machine. Do not
immerse machine in water or any other
liquid. Do not use any detergent with abra-
siveness,corrosiveorinammability(such
as bleach or alcohol) to clean any parts
oftheproduct.Thepurierusecomposite
lters,thelterscannotbewash.
1 Use soft brush to clean inlet and outlet
of air quality sensor.
2 Disassemble the cover of air quality
sensor.
3 Use dry swab to clean the air quality
sensor, air inlet and outlet.
4 Reinstall the cover of air quality sensor.
Cleantheairpurierregularlytoprevent
the dust accumulation.
1 Use soft and dry clothes to remove the
dustfromtheairpurier.
2 Use soft and dry clothes to clean the
outletandinletoftheairpurier.
Clean air quality sensor every two-month
to ensure best running performance.
Please clean often if machine works in
dusty environment.
Attention
When the room is in high humidity, air
quality sensor may force condensate water
in surface. In this condition, even the air
quality is good, air quality sensor may
show poor air quality, so you must clean
air quality sensor or set manually.

16
USER MANUAL
Change lter Operating steps
Information 1 The machine remind to replace the
lters.
2 Turn off the power, then pull out the
power plug.
3 Press play button in the back cover and
pull the cover, then you can lift the back
cover and pull out slightly.
Iftheindicatorlightoflterreplacement
is on, it is to remind users to change the
lters.
Attention
Hint
Please turn off and pull out power plug
beforereplacingthelters.
Pleaseremovethepackageofeachlter
before putting them into the machine and
pleasemakethelabeloflterfaceupward

17
USER MANUAL
4Removealltheltersassembly.
5Removeallpackagesoflters,then
installthenewltersintotheairpurier
in order.
6 To reinstall the back cover, please align
atthexedgrooveandinsertthecover
into the groove, making the play button
and frame withhold.
7Whenthelterreplacementiscomple-
ted,pluginandturnontheairpurier,
press the SPEED button and ANION
button for 3s to reset the machine.

18
USER MANUAL
Long term idling Suggested frequency of
replacing the lter net
Pull out power plug( there is also power
consumption in stand by mode)
Dry machine inside thoroughly (else there
maybe malfunction because of rust)
Place the machine in dry and ventilating
place(donotplaceatorupsidedownto
avoid malfunction)
Whenthepurierrunningfor1500hours,
theairpurierwillsendasiren,andthe
indicatorlightoflterreplacementwillon
toremindtheuserstoreplacethelter.
Atthiscondition,thepuriercanwork
normally.
Attention
Please turn off and pull out power plug
beforereplacingthelters.

19
USER MANUAL
7. Fault handling
The following table lists failure possible to appear in dairy use. Please contact company
servicecenterordealerifyoucannotndanswerfromthelistedexamples.
Status possible reason possible solution
Machine
cannot work
power supply for plug pull out the plug and pull in again
power plug or wire is wrong contact customer service center or
dealer
fan doesn’t
work
machine doesn’t turn on plug in and turn on
motor is wrong ontact customer service center or
dealer
Machine on uneven ground movetoevenandatground
loose or foreign particles come
inside
contact customer service center or
dealer
motor is loose contact customer service center or
dealer
lterpackingisnotremoved pleaseremovepackingofeverylter
bad perfor-
mance
washablelterisdirty washthedirtylter
Filters need to be replaced replacenewlter
machine inlet or outlet blocked contact customer service center or
dealer
lterplasticpackingisnot
removed
removed packing and then use .
there is no enough space
around machine
please ensure there is 50cm distance
between two- side air inlet, the distan-
ce to air outlet is not less than 10 cm.
lackofllerorthellerisnot
properly placed
Makesurealltheltersareplacedin
order in accordance with instructions
exceed cover check whether room area is in ac-
cordance with the machine effective
cover area.

20
USER MANUAL
Warranty and service
Fittings
Order parts or accessories
If you want to know more information or
have any questions , please contact custo-
mer service center or the dealer.
Productspecicationmaybechanged
without prior notice .
Waranty 2 years from the purchase day
under normal use and surounding condi-
tions.
If you want to change parts or purcha-
se additional parts, please contact your
customer service center or the dealer.
Fibrelter+HEPAlternet+Activatedcarbonlter
Table of contents
Other Faton Air Cleaner manuals
Popular Air Cleaner manuals by other brands

EnviroPureFX
EnviroPureFX EPFX MF3225 owner's manual

Taurus
Taurus Serenity Ozonic user manual

Trion
Trion FM 1000 Installation, operation & service

FilterStream
FilterStream AirTamer Professional A710 instruction manual

Hunter
Hunter HEPAtech 30078 owner's manual

pureguardian
pureguardian AC4220 Use & care instructions