DeepSea Power & Light SeaLite Lumos 1000 User manual

SeaLite®Lumos
Record product serial number below as it appears on the nameplate.
Serial #
Pin-out
• Postive = Pin
• Negative = Pin
• Ground = Pin
• Dimming (if applicable) = Pin
DEEPSEA
POWER & LIGHT
®
Operator’s Manual
T: (858) 576-1261
F: (858) 576-0219
4033 Rufn Road
San Diego, CA
92123- 1817 USA
www.deepsea.com
Original Instruction
REV 07/01/15
SeaLite
®
Lumos

Specication Overview
* Specications subject to change without notice.
2
SeaLite®Lumos Operator’s Manual
Mechanical Specications
Housing Anodized 6013 Aluminum
Titanium (optional)
Port Sapphire
Outer Diameter 46.9 mm (1.85 in.)
Overall Length
(w/o connector) 155 mm (6.09 in)
Weight in Air Al housing: 530 g (1.17lbs)1
Ti Housing: 710 g (1.56 lbs)2
Weight in Water Al housing: 230 g (0.51 lbs)1
Ti Housing: 400 g (0.88 lbs)2
Environmental Specications
Depth Rating 6,000 m (20,000 ft)
Operating Temp. -10º C to 40º C (14º F - 104º F)
Optical Specications
Colors Day Light White3
Lumens in Water 3000 typical
Color Temp/Wavelength 5000K - 6500K*4
Beam Pattern Flood: 85º or Spot: 32º
Electrical Specications
Lumos 2000 Lumos 1000
Input Voltage 10-36V DC 90-270V AC, 50/60Hz
100-350V DC
Current 1.10A @ 24V DC
2.65A @ 10V DC
0.27A @ 120V AC
0.13A @ 240V AC
Power 26.5W max 32.0W max
Dimming 0-5V DC AC phase control (TRIAC)
variable voltage (VARIAC)
Dimensions
1.87
47.5
1.69
42.9
2.47
62.6
2.40
60.9
1.59
40.3
.59
15
6.08
154.3
7.35
186.7
1.85
47
1.00
25.4
1.00
25.4
4X 1/4-20 UNC
OR
4X M6 x 1.0
[inch]
mm
Standard Connectors
MCBH3MP
(High Voltage AC/DC)
1 = Hot (DC +)
2 = Neutral (DC -)
3 = Chassis
MCBH5MP
(Low Voltage DC)
1 = DC+
2 = DC-
3 = Chassis
4 = Not Used
5= 0-5 V DC Control
(0-5V DC Control referenced
to Pin 2)
*Other connector options
are available upon request.
1 Aluminum Housing, Low Voltage Driver, Flood Reector model.
2 Titanium Housing, Universal Driver, Spot Reector model.
3 Other color options available.
4 Other color temperatures available.
1
2
3
3
5
4
1
2

SeaLite®Lumos
Operator’s Manual
3
Table of Contents
Specification Overview 2
Table of Contents 3
Safety Symbols 4
General Notes and Warnings 4
Pre Dive Inspection 4
Post Dive Inspection 4-5
Troubleshooting 5
Flooded Light Repair 5
Limited Warranty 5
RMA Procedure for Repair 5
Appendix A: Dimming Response Curve 6
Appendix B: Driver Efficiency 9
Appendix C: LVDC Step Response Curve 11
Appendix D: Beam Patterns 14

SeaLite®Lumos Operator’s Manual
4
Safety Symbol
In this operator’s manual and on the product, safety symbols are used to communicate important
safety information. This section is provided to improve understanding of these symbols.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to
avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, could result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE indicates information that relates to the protection of property.
This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information
on the safe and proper operation of the equipment.
This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of
eye injury.
This symbol indicates the risk of electrical shock.
DANGER
!
WARNING
CAUTION
NOTICE
General Notes and Warnings
You may run your SeaLite® Lumos in air. As the light
heats up you will notice that the output will diminish. This
is normal, and the light will return to full brightness once
it is submerged and allowed to cool down.
DANGER
When the SeaLite®Lumos is operated in air the body
may reach temperatures in excess of 65° C. These
temperatures may be enough to cause burns if the light
is handled without protective clothing.
Do not operate any high voltage electrical equipment in
or around water without using a Ground Fault Interrupt
circuit (GFI) and an isolation transformer, especially
when divers are in the water.
WARNING
Do not clean any part of the light head with any type of
alcohol.
There should be no reason to ever open the body of
your SeaLite®Lumos light. There are no user serviceable
parts inside your new underwater light.Your SeaLite®
Lumos was thoroughly pressure tested prior to leaving
the factory to confirm the integrity of the complete
assembly. Opening the housing may cause potential
problems when resealing.
Pre and Post Dive
Inspection
Check to make sure that the rear bulkhead connector is
secure before deployment.
Check the following areas for previous damage, wear or
corrosion: rear bulkhead connector, power cable, front
window.
Rinse your SeaLite®Lumos in fresh water after use in
saltwater.
DANGER
After each deployment, carefully check to make sure
the light is operational and has not flooded. If it gets
flooded, upon surfacing, the light can become internally
pressurized, which may be potentially dangerous.
Additionally, if the power remains on when the light has
partially flooded, it is possible for electrolytic generation
of an explosive mixture of hydrogen and oxygen gases.
If a light appears flooded upon removal from the water,
it should be treated as potentially dangerous. Point the
light away from persons and valuable equipment and
make sure that the power is disconnected. See the
Flooded Light Repair procedure for more information.

SeaLite®Lumos
Operator’s Manual
5
Troubleshooting
If the light stops working while underwater assume that
it has been flooded. See Flooded Light Repair procedure
below.
Once it has been determined that the light is not flooded,
or if it does not turn on during pre-deployment checks,
check the input power cable/inline connector to make
sure that correct voltage is being supplied, and that the
correct pinout is being used. See page 2 of this manual
for electrical specs and connector pin assignments.
If the light still does not work, return it to DSPL using the
RMA Procedure for Repair below.
Flooded Light Repair
If the light stops working while underwater, you should
assume that it has been flooded. When working on a
potentially flooded light, it is important to use appropriate
personal protective equipment to include, at a minimum,
eye and hand protection.
1. Place the light face down on a table making sure
that the connector side is facing up.
2. Slowly unscrew the connector/socket assembly to
allow any internal pressure to be equalized.
3. Once it is determined that the light is not
internally pressurized, it is recommended that
the light be returned to DeepSea Power & Light
(DSPL) for evaluation and repair using the RMA
Procedure.
RMA Procedure for Repair
Should it be necessary to return your light to the factory,
follow the procedure for the Flooded Light Repair above,
leaving the connector partially unscrewed. For warranty
and non-warranty repairs please contact DeepSea
Power & Light for a RMA number prior to returning
your item. Please have your light model number, serial
number and any other pertinent information along with
a description of the problem, on hand when you call, or
include them in a fax or e-mail. When shipping your item,
be sure that the freight is pre-paid (CODs will not be
accepted) and that the RMA number is clearly printed on
the outside of the box.
All shipments should be sent to the address below:
DeepSea Power & Light
Attn: RMA ####
4033 Ruffin Road
San Diego, CA 92123-1817
U.S.A
Tel: (858) 576-1261
Fax: 858-576-0219
e-mail: [email protected]
Limited Warranty
Seller warrants that the goods (except internal electronic
components) sold under this contract will be free from
defect in material and workmanship for a period of
one year from the date of shipment from the factory,
if they have been properly used. Internal electronic
components are warranted for 90 days from the date
of shipment from the factory, if they have been properly
used. This warranty will be limited to the repair or
replacement of parts and the necessary labor and
services required to repair the goods. IT IS EXPRESS
LY AGREED THAT THIS WARRANTY WILL BE IN LIEU
OF ALL WARRANTIES OF FITNESS AND IN LIEU
OF THE WARRANTY OF MERCHANTABILITY. This
warranty is the exclusive and only warranty to pass with
the goods under this contract. No agent, employee, or
representative of the Seller has any authority to bind
Seller to any information, representation, or warranty
concerning the goods sold under this contract, and
unless an affirmation, representation, or warranty
made by an agent, employee, or representative is
specifically included within this contract, it will not be
enforceable by Buyer. If notice of defect is given to
DeepSea Power & Light, Inc. within such 90 day or one
year warranty period, the sole obligation of DeepSea
Power & Light, Inc. shall be to furnish new or repaired
parts free of charge in exchange for parts which have
been proved defective and does not include any other
costs such as the cost of removal of the defective part,
installation, labor, or consequential damages of any
kind, the exclusive remedy being to require DeepSea
Power & Light, Inc. to furnish such new parts. Under
no circumstances shall the Buyer be entitled to recover
any incidental damages as that term is defined in
Commercial Code §2715.
www.deepsea.com
4033 Rufn Road
San Diego, CA
92123-1817 USA
T: (800) 487-3775
F: (858) 576-0219

SeaLite®Lumos Operator’s Manual
6
Appendix A
Dimming Response Curves

SeaLite®Lumos
Operator’s Manual
7
0%
20%
40%
60%
80%
100%
0° 20° 40° 60° 80° 100° 120° 140° 160° 180°
% Output
Input Phase Angle
SeaLite Lumos 1000 Phase Cut Dimming Response
SLL-1000 120VAC 60Hz SLL-1000 240VAC 50Hz
0%
20%
40%
60%
80%
100%
0V 20V 40V 60V 80V 100V 120V 140V 160V
% Output
Input RMS Voltage
SeaLite Lumos 1000 Variable Voltage Dimming Response
SLL-1000 120VAC 60Hz SLL-1000 High Voltage DC

SeaLite®Lumos Operator’s Manual
8
0%
20%
40%
60%
80%
100%
0.0V 1.0V 2.0V 3.0V 4.0V 5.0V 6.0V
% Output
Dimming Input Voltage
SeaLite Lumos 2000 Analog Dimming Response

SeaLite®Lumos
Operator’s Manual
9
Appendix B
Driver Efficiency

SeaLite®Lumos Operator’s Manual
10
0%
20%
40%
60%
80%
100%
60V 110V 160V 210V 260V 310V 360V
Efficiency
Input RMS Voltage
SeaLite Lumos 1000 Efficiency
SLL-1000 VAC 60Hz SLL-1000 VAC 50Hz SLL-1000 DC
0
0.5
1
1.5
2
2.5
3
3.5
0%
20%
40%
60%
80%
100%
6V 12V 18V 24V 30V 36V
Current (A)
Efficiency
Input DC Voltage
SeaLite Lumos 2000 Efficiency
Efficiency Input Current

SeaLite®Lumos
Operator’s Manual
11
Appendix C
Low-Voltage DC Step Response Curve

SeaLite®Lumos Operator’s Manual
12
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0V
1V
2V
3V
4V
5V
-10 0 10 20 30 40 50
% Output
Control Pulse (V)
Time (ms)
SLL-2000 DIM Input Step Response Characteristics
Trigger % Output

SeaLite®Lumos
Operator’s Manual
13
DIM Input Pulse Response: Rise Time SLL-2000 LVDC
DIM Input Pulse Response: Fall Time SLL-2000 LVDC

SeaLite®Lumos Operator’s Manual
14
Appendix D
Beam Patterns

SeaLite®Lumos
Operator’s Manual
15
Lumens: Lumens:
Peak Lux: Peak Lux:
FWHP Angle: FWHP Angle:
NOTE: Beam pattern data for a representative sample of the indicated product configuration only.
87
1831
5160
34
1550
SeaLite Lumos Spot
SLL-1000-DW-S-PV
SeaLite Lumos Flood
SLL-2000-DW-F-A05
2607
0
1000
2000
3000
4000
5000
6000
-90 -85 -80 -75 -70
-65
-60
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Radial Lux Intensity Comparison
-90.0°
-80.0°
-70.0°
-60.0°
-50.0°
-40.0°
-30.0°
-20.0°
-10.0°
0.0°
10.0°
20.0°
30.0°
40.0°
50.0°
60.0°
70.0°
80.0°
90.0°
0% 25% 50% 75% 100%
Degrees
% Output
Angular Distribution
Lux
This manual suits for next models
1
Table of contents