Del ozone MCD Series User manual

MCD
Corona Discharge Ozone Generators
MANUFACTURED BY
3428 Bullock Lane
San Luis Obispo, CA 93401
4-0622 Rev. A
LIMITED WARRANTY INFORMATION
The limited warranty, set forth below applies to products sold by DEL Ozone and its authorized
dealers. This limited warranty is given only to the f rst retail purchaser of such products and is not
transferable to any subsequent owners or purchasers of such products. DEL Ozone warrants that
it or its authorized dealers will repair or replace, at its option, any part of such products proven
to be defective in materials or workmanship within one (1) year of the date of retail purchase of
such products. ANY REPAIR OR REPLACEMENT WILL BE WARRANTED ONLY FOR THE BAL-
ANCE OF THE ORIGINAL WARRANTY PERIOD. NOTE: USE ONLY DEL Ozone AUTHORIZED
REPLACEMENT PARTS. USE OF ANY OTHER PART(S) WILL AUTOMATICALLY VOID THIS
WARRANTY. THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF THE FOLLOWING:
(a) any labor charges for trouble-shooting, removal, or installation of such parts; (b) any repair or
replacement of such parts necessitated by faulty installation, improper maintenance, improper
operation, misuse, abuse, negligence, accident, f re, repair materials, and/or unauthorized acces-
sories; (c) any such products installed without regard to required local codes and accepted trade
practices; (d) ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED W ARRANTY
OF FITNESS FOR PARTICULAR PURPOSE, AND SUCH WARRANTIES ARE HEREBY DIS-
CLAIMED; AND (e) DEL Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR
LOSS OF USE OF SUCH PRODUCTS, LOST PROFITS, DIRECT DAMAGES, INDIRECT
DAMAGES, CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL DAMAGES. This warranty
gives you specif c legal rights. You may also have other rights which vary from state to state.
TO OBTAIN WARRANTY SERVICE:
Contact: DEL Ozone
3428 Bullock Lane, San Luis Obispo, CA 93401
Customer Service Number: (800) 676-1335
When f ling a claim, you must provide: 1) your name, mailing address and telephone number; 2)
the selling dealer’s name; 3) proof of date of purchase; 4) the date of failure; and 5) a descrip-
tion of the failure.
After this information is provided, DEL Ozone will issue a RETURN GOODS AUTHORIZATION
(RGA) NUMBER. After receiving this number , the part in question must be returned to DEL
Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All
pre-authorized defective parts must be returned to DEL Ozone within thirty (30) days. Under no
circumstances may any product be returned to DEL Ozone without prior authorization. You must
call or write f rst or your returned goods shipment will be refused. Upon receipt of pre-authorized
returned goods, DEL Ozone will repair or replace, at its option, the defective product(s) and return
them freight collect. Buyer ’s acceptance of the product and use thereof constitutes acceptance
of these terms.
www.SpaDepot.com

CD ELECTRODE REPLACEMENT RECORD SHEET
Use the following form to record your ozone cell and power supply replacement infor-
mation. For optimum performance, we recommend the ozone cell and power supply be
replaced every two years. Fill out the following form each time you replace the ozone
cell and power supply. This will help you remember to replace them every two years.
DATE REPLACED COMMENTS
SAVE THIS FORM!

IMPORTANT SAFETY INSTRUCTIONS
When installing and using DEL Models MCD, basic safety precautions should always
be followed:
Be sure all the electrical power is shut OFF at the main circuit breaker before installing
the MCD.
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. All permanent electrical connections should be made by a qualif ed electrician.
3. Follow all applicable electrical codes.
4. Be sure all the electrical power is shut off at the main circuit breaker
before installing the MCD.
5. If the MCD electrical connections will be attached directly to the spa controls, be
sure the spa controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.).
If the MCD is connected to an independent electrical supply, then a G.F.C.I. must
be installed between the MCD and the electrical supply.
6. Do not bury cord.
7. WARNING: To reduce the risk of electric shock, replace a damaged cord immedi-
ately.
8. The MCD must be mounted indoors or, under a cover, sheltered from natural ele-
ments (rain, sun, sprinklers).
9. The MCD must be mounted above the water line.
10. Mount the MCD so that it is inaccessible to anyone in the spa.
11. Mount the MCD using the mounting tabs such that the MCD is vertical with the
vents facing downward.
12. Install a check valve in the tubing between the MCD and the vacuum source.**
13. Plastic ozone supply tubing is supplied with the MCD. Never replace this tubing
with metal tubing.
14. Do not operate the MCD unless suf f cient air f ow is being drawn through the
unit.
15. WARNING: Short term inhalation of high concentrations of ozone and a long term
inhalations of low concentrations of ozone can cause harmful physiological effects.
Do not inhale ozone gas produced by this device.
16. SAVE THESE INSTRUCTIONS.
** A condensate may collect in dips or loops in the tubing. For best results install the
MCD just above the vacuum source and use a short, straight piece of tubing to
make the connection. If condensation appears in the tubing, DO NOT DRAIN IT,
the moisture may be moderately corrosive. Disconnect the power to the MCD and
allow the liquid to be drawn out or dried up before removing the tubing.
SAVE THESE INSTRUCTIONS.
DELQUIK BASIC WATER CHEMISTRY CHART

MCD MAINTENANCE INSTRUCTIONS
The MCD is equipped with a replaceable ozone cell and power supply. For optimum perfor-
mance, we recommend the ozone cell and power supply be replaced every two years. It is also
recommended that the o-ring, hose barb insert, and fuse be replaced at the same time.
New replacement parts can be ordered from your local dealer using the following DEL part
numbers:
MCD-50, US and Canada............................................9-0743-01
MCD-50, Europe..........................................................9-0744-01
MCD-250, US and Canada..........................................9-0745-01
Follow the steps below to replace the old ozone cell, power supply, o-ring, hose barb insert,
and fuse. REFER TO FIGURE 1 ON OPPOSITE PAGE.
STEP 1 - Remove the MCD from your spa.
1. Shut off power to the MCD or to the spa, and disconnect the MCD power cord from the
spa control pack.
2. Disconnect the ozone tubing from the MCD ozone outlet hose barb.
3. Remove the screw from the bottom mounting tab.
4. Back the upper mounting tab screw out about two turns and lift the MCD up and off of
the spa.
STEP 2 - Remove the MCD Cover
1. Remove the cover screw on the back side of the base of the MCD.
2. Using a f athead screwdriver or f ngers, pry the two cover tabs outward to release the
cover from the base.
3. Lift the cover up.
4. Slide cover forward and off.
STEP 3 - Remove the old ozone cell, power supply, hose barb insert, & fuse.
1. Remove power supply mounting screws.
2. Disconnect power supply connector (red & black wires).
3. Lift ozone cell up and out of hose barb insert (o-ring and hose barb insert may remain
attached to ozone cell).
4. Remove and discard ozone cell (with o-ring), power supply, & hose barb.
5. Carefully pull circuit board vertically out of base slot & remove old fuse.
STEP 4 - Install the new ozone cell, power supply, hose barb insert, o-ring, & fuse.
1. Insert new fuse and carefully push circuit board back into base seat.
2. Insert new hose barb insert making sure to align the hose barb correctly and insert it
completely into its slotted hole.
3. Install power supply and mounting screws. Route power supply wires through pegs.
4. Place new o-ring onto ozone cell outlet (reference old location).
3. Install ozone cell by inserting into hose barb and gently pushing into cradle.
4. Connect ozone cell to power supply connector.
5. Slide cover into position while lifting the base of the cover up.
6. Lower cover over ozone cell and snap cover tabs into place.
7. Replace cover screw.
8. Reinstall the MCD into the spa, reconnect ozone supply tubing to hose barb and recon-
nect the power cord.
Figure 1. MCD Component Locations
O-RING
OZONE CELL &
POWER SUPPLY
ASSEMBLY
This manual suits for next models
2
Table of contents
Other Del ozone Portable Generator manuals
Popular Portable Generator manuals by other brands

Phoenix Mecano
Phoenix Mecano Okin POWER PACK 1800 Installation instruction

Generac Power Systems
Generac Power Systems QT05030AVAN owner's manual

ACD
ACD CAL-101 instruction manual

Gude
Gude GSE 4701 RS Translation of the original instructions

Huck
Huck POWERIG 940-220 instruction manual

Extron electronics
Extron electronics BBG 6 A J user guide