14 Part Number: 9294045 10/14
Operation Section 3
Controls/Programming/Settings
REFRIGERATORS
After the unit is connected to power it will automatically
begin operating. With the doors closed, the temperature
of the cabinet should reach 36°F to 40°F (2°C to 4°C) on
refrigerators in about one hour.
A thermostat located in the evaporator housing on interior
rear of the unit, controls the temperature in the box. The
factory setting for the control is 4 and maintains about 38°F
(3°C) in the box. Set toward 1 for higher temperatures and
toward 7 for lower temperatures.
Refrigerators defrost automatically with every cycle of the
compressor. The water generated is routed to a pan on the
rear of the unit and is evaporated by the heat given off by
the compressor.
During normal operation the evaporator fan may cycle
and/or pulse independently of the compressor. Consult
the service manual or contact Technical Support at
1-844-724-CARE if you are unsure of the proper
function.
FREEZERS
After the unit is connected to power it will automatically
begin operating. With the doors closed, the temperature
of the cabinet should reach 0°F (-18°C) on freezers in about
one hour. The electronic temperature control constantly
monitors box temperature as well as evaporator coil
temperature to maintain consistent product temperatures.
As an added energy-saving feature, the electronic controller
will switch the evaporator fan motor on and off with the
compressor and condenser fan motor.
At initial start-up or anytime power is disconnected, then
reconnected to the unit, the control will delay all operations
for a short time (up to 10 minutes.) While in this delay
period, the control initializes the control parameters and
confirms that the temperature sensors and circuits are
operational.
During normal operation the evaporator fan may cycle
and/or pulse independently of the compressor. Consult
the service manual or contact Technical Support at
1-844-724-CARE if you are unsure of the proper
function.
Important Note
After initializing, the control will immediately enter a
DEFROST mode. The compressor and condenser fan as
well as the evaporator fan will remain off until initial defrost
is complete. This initial defrost cycle may take up to 15
minutes to complete, at which time the freezing cycle will
begin.
Whenever the freezer is plugged in, and the control has
completed initializing including the initial defrost cycle
(see above), the electronic temperature control will cycle
the compressor, evaporator fan motor, and condenser fan
motor to maintain box temperature at the control setting.
Freezer Automatic Defrost
The control also monitors compressor total running time
and will enter a defrost cycle after total compressor running
time is greater than five hours since the last defrost cycle
OR if evaporator coil temperature drops below -34°F (-37°C)
(indicating excessive frost on the coil).
Freezer Manual Defrost
If a manual defrost is desired, simply unplug the unit for
several seconds, then plug unit back in. This will cause the
control to re-initialize and then enter a defrost cycle.
When the control enters the defrost mode, whether manual
or automatic, it switches off the evaporator fan motor,
compressor and condenser fan motor, and switches on the
defrost heater to warm the evaporator coil and melt all frost
accumulated during the previous refrigeration cycle. The
control will continue the defrost cycle for a MINIMUM of
eight minutes and a MAXIMUM of 30 minutes depending