Desisti MAGIS 650W User manual

MAGIS 650W
Quartz-Halogen Fresnel SPORTLIGHT
INSTRUCTION MANUAL

1. INTRODUCTION
Congratulations on your purchase of MAGIS 650W lighting fixture from De Sisti. Our commitment to total
customer satisfaction and our consolidated experience and leadership in design innovation and manufacturing
of lighting products for the professional entertainment industry menas you can depend upon the quality of this
product.
The Magis 650W is a compact, highly efficient Fresnel lens spotlight using tungsten-quartz halogen filament
lamps having GY 9,5 socket, L.C.L. of 46 mm. and max. 650W power.
NOTE: PO Version is available on special request and it is supplied with the stirrup fitted on.
2. YOKE AND ACCESSORIES ASSEMBLY

3. SAFETY INSTRUCTIONS
!- Professional use: this luminaire has been designed for professional use and must be
operated by qualified personnel only. Not for residential use.
!- Grounding: WARNING: This luminaire must be grounded
!- Electrical connections: IMPORTANT: the cores in this mains lead are colored in
accordance with the following code:
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please
proceed as follows:
- the green or green and yellow core must be connected to the connection point marked with the letter E or with
the symbol or colored on green or in green-yellow
- the blue (or white) core must be connected to the connection point marked with the letter N or colored in black
- the brown (or black) core must be connected to the connection point marked with the letter L or colored in red
Working conditions
!Working Position
Lighting fixture: Max. Tilting ±90° from horizontal
Lamp: S90
!Ambient Temperature, ta
+45°C Max.
!Minimum distances from
inflammable surfaces
Top
Back
Sides
Front
0,3 m.
0,1 m.
0,1 m.
0,75 m.
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above
table are the minimum distances recommended. Other requirements for safe use are:
A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.
B. Use only original accessories and spares from De Sisti Lighting.
C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the
luminaire weight.
D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.
E. A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the
suspension point and the eyelet at the front of the body .
WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE .
4. INSTALLATION INSTRUCTIONS
Before connecting the luminaire to the electrical mains ensure that:
A. Earth line is present on the power socket.
B. The mains voltage is within the rated range of the luminaire (see technical data on the rating label)
C. The lamp fitted:
-is among the usable lamps (see point 6 or check with your De Sisti dealer)
-has the same nominal voltageas the mains supply
-has a nominal voltage not higher than maximum power of the luminaire
EUROPE
AMERICA
Ground
Green & yellow
Green or green & yellow
Neutral
Blue
White
Live
Brown
Black

D. The front safety shields against the lamp explosion are present and in a good condition
They consist of Fresnel lens plus wire guard. The Fresnel lens is made by borosilicate untoughened
glass D = 120 mm. thickness = 4 mm. typ (3 min), compliant to DIN 15560. The wire guard is a
mesh 25 mm. x 25 mm. (or smaller), wire D = 0,8 mm. typ, made by nickel coated steel.
WARNING: SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY
HAVE BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS
IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.
THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD
5. LAMP INSTALLATION AND REPLACEMENT
The following procedure should be adopted:
A. Ensure the luminaire is electrically isolated from the power supply
B. Wait least 5 minutes from switching off to avoid risk of injury from possible lamp
explosion. Then open lens door
WARNING: after the above mentioned time the lamp may still be very hot, use proper
thermal protection (Eg. Gloves)
C. Check that the new lamp is of the correct type (see item 4 C)
D. Replace the lamp taking good note of the following:
-do not touch the bulb with bare-hands; oil and grease can contaminate the bulb
surface and than reduce the performance and the lamp life
-the plastic cover which protects the lamp should not be removed until after fitting
-Should the bulb become dirty due to hand contact or for any other reaon, it can be
cleaned with a cloth moistened with alcohol
E. Ensure that the lens door is securely closed
WARNING: THE LAMP MUST BE REPLACED IF IT HAS BECOME DAMAGED OR DEFORMED

6. CHARACTERISTICS AND PERFORMANCE DATA
DESCRIPTION
VALUE
- Amperage
Europe – 230V
2,9 A (650 W)
America 120 V
5.5 A (650 W)
- Power Supply
Europe
230 V – 0-60 Hz
America
120 V / 0-60 Hz
- Switch on line
M.O. & P.O.
Toggle: 16A/125V 8A/250V
Lamp Holder
GY 9,5
Power Cable
Europe
3 x 1,5 mm2– 150°C
(0,5 m silicon 180°C + 3 m H07RN-F 90°C)
3 x 16 Awg
(0,5 m high T 200°C
+ 3m SO 90°C + Plug)
Protection Class
Class 1 – ground connection required
Protection Type
IP 22
Max. housing surface temeprature
220°C
Weight of fixture
M.O.
4,7 kg
P.O
Kg..
Weight of barndoor
4 leaf
kg.
8 leaf
kg
Size of barndoor ring
Seat diameter
mm
Ring diameter
mm (7’’ ½)
Size of scrims & color frame
Seat diameter
mm
Accessory diameter
mm (7’’ ¼)
Lens diameter
120 mm
USABLE LAMPS
base-watt-filament
230 V
120 V
ANSI
LIF
ANSI
LIF
GY 9,5 – 300 W – M Sh
FSL
CP 81
FKW
CP 81
GY 9,5 – 500 W - MP
FRH
CP 82
FRG
CP 82
GY 9,5 – 650 W - MP
FRL
CP 89
FRK
CP 89
7. PERIODIC INSPECTION
A. The condition of the internal wiring insulation and of the input cable shall be inspected and tested every
500 working hours and at least once a year. This frequency may need to be increased if rough or unknown
(eg. Rental) treatment is incurred. Replace only with original De Sisti spare parts. Non-original cables may
not withstand the thermal and mechanical conditions of use
B. The lamp condition must be checked every 100 working hours. For lamp replacement follow the procedure
of point 5 and the instruction of the lamp manufacturer.
C. Check the condition of the safety shield (see chapter 4-D – Installation Instructions) before every use.
8. SAFETY STANDARDS
Europe: The product conforms the Applicable European Directives &
Standards
America: the product
conforms NEC & UL stds.
-Low voltage directive: 73/23/EEC (as amended by 93/68/EEC)
-EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by
93/68/EEC)
-European Standards: EN 60598-2-17, EN 60598-1, EN 61547
UL Standard: 1573
Approved by UL: file
E116219
Table of contents
Other Desisti Floodlight manuals
Popular Floodlight manuals by other brands

Sealite
Sealite BargeSafe 3NM Installation & service manual

Malibu Boats
Malibu Boats CL9S quick start guide

Acclaim Lighting
Acclaim Lighting Dyna Accent user guide

Emos
Emos ZS2811 manual

Deluce Lighting
Deluce Lighting DLPLBLKPPIR Fitting instructions

Larson Electronics
Larson Electronics Golight RadioRay 7901 Instruction guide

Sylvania
Sylvania ValueLED Flood1C with Slipfitter installation guide

EuroLite
EuroLite DMX OPERATOR user manual

American DJ
American DJ WIFLY PAR QA5 Specifications

Art Lighting Production
Art Lighting Production ASTERION operating instructions

IVT
IVT PL-838B operating instructions

CLARIUS
CLARIUS Clarius STAR quick start guide