3
Wiring the Floodlight
• Ensure that the mains supply is isolated before commencing installation.
• A suitable rated connector must be used to connect the lead from the oodlight to
the mains supply.
• Connect the mains cable to the connector. Ensure that the correct polarities for
Live, Neutral and Earth are observed i.e.
- Green/yellow - Earth terminal
- Brown - Live terminal
- Blue - Neutral terminal
• After wiring, check that there are no stray strands and that all the wires have been
correctly installed.
• Before connecting power, perform the electrical tests specied in the current
Building and IET Wiring Regulation to ensure that the installation is safe and that
the wiring has been performed correctly.
• Restore the mains power supply and check that the oodlight illuminates the
required area. Tighten the oodlight using the bolts on the brackets.
SPECIFICATION
CLEANING & MAINTENANCE
• Clean the oodlight only with a soft dry cloth. Do not use any chemicals, abrasives
or solvents that could damage the oodlight.
• The oodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the oodlight
will have to be replaced.
PEL00930 PEL00931 PEL00932 PEL00933
Input Voltage 220-240V AC
50/60Hz
220-240V AC
50/60Hz
220-240V AC
50/60Hz
220-240V AC
50/60Hz
Nominal luminous ux 700lm 1400lm 2100lm 3500lm
Wattage 10W 20W 30W 50W
Beam angle 120° 120° 120° 120°
Dimmable No No No No
Nominal lifetime of the lamp
20,000h 20,000h 20,000h 20,000h
Light source SMD2385 SMD2385 SMD2385 SMD2385
Colour temperature 6000K 6000K 6000K 6000K
Colour rendering (CRI Ra) ≥80 ≥80 ≥80 ≥80
Warm up time
(60% full light)
Instant full
light
Instant full
light
Instant full
light
Instant full
light
Ingress rating IP65 IP65 IP65 IP65
Earthing Class I Class I Class I Class I
Weight 0.225kg 0.340kg 0.522kg 0.608kg
Dimensions WxHxD (mm) 105 x 77 x 28 134 x 98 x 34
173 x 126 x 37 173 x 126 x 46