Signal and Sensor Power Connector – P2
Ground reference for signals and power.
This signal to ground will activate the operator. If the module is in the ON mode (Low
voltage ON/OFF must be to ground) and no current fault is present. Note: Manual use of
the door will not enable this input.
This signal is active when the door is in motion . IF the module is in the ON mode (Low
voltage ON/OFF must be to ground) and no current fault is present. Note: Manual use of
the door will not enable this mode.
When the door is fully closed , this signal to ground will prevent an activation. During the
opening cycle (with lockout option to OFF), the door will go to safety speed when this
signal is to ground. During the closing cycle (with lockout position to OFF ), the door will
go to a very slow speed when this signal is to ground. When the door is fully opened, this
signal to ground will prevent the door from entering the closing cycle.
When the door is fully closed , this signal to ground will prevent an activation. During the
opening cycle , the door will go to safety speed when this signal is to ground. When the
door is fully opened, this signal to ground will prevent the door from entering the closing
cycle .
This signal to ground will start the delayed activation timer . When the timer expires, an
activation is generated. This signal is used to do door sequencing.
This signal to ground will hold the door opened. If the module is in the ON mode, (Low
voltage ON/OFF must be to ground) and no current fault is present.
This signal to ground enables the module. This module is disabled if this signal is not to
ground.
This is a signal output for sensor which requires door status information.
When door is closed, Data output is 0V
When door is in the opening cycle, Data output is 12V
When door is closing (in motion), Data output is 8V
Ground reference for signals and power
DC power to sensors (300mA max.)
AC power for sensor
This connection is the common to drive an electric lock . (Active when electric lock option
is set to ON )
This connection is the normally open (NO) to drive an electric lock (Active when electric
lock option is set to ON )
This connection is the normally closed (NC) to drive an electric lock (Active when electric
lock option is set to ON )
J2.1 Logic ground
J2.2 Activation 1
J2.3 Activation 2
J2.4 Safety A
J2.5 Safety B
J2.6 Delayed Activation
J2.7 Hold Open
J2.8 Low Voltage
ON/OFF
J2.9 Data +
J2.10 Logic ground/Data -
J2.11 (+24VDC)
J2.12 (24VAC)
J2.13 (24VAC)
J2.14 Electric lock switch
(Common)
J2.15 Electric lock switch
(normally open)
J2.16 Electric lock switch
(normally close)
DefinitionPin Signal
Pin Signal Definition
J3.1 AC Line - BLK
J3.2 AC Neutral - WHT
J3.3 AC Ground - GRN
Power required is 120 VAC 50/60 Hz (Maximum current is 3Amperes
Power Source (120VAC input connector ) – J3
3
High Energy use and must conform to ANSI/BHMA A156.10
High - Low
Low
Energy
Low
Energy
ANSI/
BHMA
A156 .19