DS410 Instruction manual, REV 1, © 2019 MOBILELOCK LLC
MOBILELOCK™
DS410 Power Switch Adaptor
OTE: This product works only with the DS600 Mobilelock
GENERAL SA ETY RULES
Warning: Read and understand all instructions and warnings before
using this product.
CAUTION: POT NTIAL QUIPM NT MALFUNCTION OR FAILUR
Do not use near water. Damage to the equipment may occur. Equipment should not be
exposed to liquids or extreme humidity. Do not touch the electronic components inside the
device.
Product unction
The MOBILELOCKTM DS410 Power Switch allows an external siren, strobe, camera or other
device to be connected to your DS600 Mobilelock and activate on an alarm. Plug the connector
that looks like a USB into the data port on the DS600. Connect the load that is to be controlled
by the switch to the ormally Open and Common connections on the DS410 terminal block. To
control the switch, log into your MOBILELOCKTM account and select your device on the
"Configure Units" page. Under Sensors, in the Unit Settings area, select “Manage Plug-In
Sensors”. Check the box “I2C Power on Alarm” box and select a length of time you wish for the
siren or strobe to run after an alarm happens. Then click “Submit Changes”.
Wiring Instructions
The following instructions are for wiring the DS406 siren to the DS410 Power Switch:
For a pulsed siren sound: Connect the siren's white wire into the “ O” port ( ormally Open) on
the DS410 using 16-18 gauge low voltage wire. Expose just enough of the bare wire before
inserting and screw securely in place. Connect the siren's red wire to the + on the 12vdc
adapter or + on the battery. Then connect the – on the 12vdc adapter or - on the battery to the
“COM” port on the DS410. Tape off the siren's unused yellow wire. For a steady siren tone use
the yellow wire instead of the red wire and tape off the unused red wire.