Dexin NDS357X User manual

NDS357X IRD User’s Manual
Web-NMS Version: 1.05
Software: 2.00
Hardware: 0.20
Chengdu Dexin Digital Technology Co., Ltd.

NDS357X IRD User‟s Manual
About This Manual
Intended Audience
This user manual has been written to help people who have to use, to integrate and to install
the product. Some chapters require some prerequisite knowledge in electronics and
especially in broadcast technologies and standards.
Disclaimer
No part of this document may be reproduced in any form without the written permission of
the copyright owner.
The contents of this document are subject to revision without notice due to continued
progress in methodology, design and manufacturing. DEXIN shall have no liability for any
error or damage of any kind resulting from the use of this document.
Copy Warning
This document includes some confidential information. Its usage is limited to the owners
of the product that it is relevant to. It cannot be copied, modified, or translated in another
language without prior written authorization from DEXIN.

DIRECTORY
Chapter 1 Product Outline................................................................................1
1.1 Outline......................................................................................................................1
1.2 Features....................................................................................................................1
1.3 Specifications............................................................................................................1
1.4 Principle Chart ..........................................................................................................2
1.5 System Connection Sample........................................................................................3
1.6 Appearance and Description.......................................................................................3
Chapter 2 Installation Guide.............................................................................5
2.1 Acquisition Check .....................................................................................................5
2.2 Installation Preparation ..............................................................................................5
2.3 Wire‟s Connection.....................................................................................................7
2.4 Signal Cable Connection............................................................................................7
Chapter 3 Operation.........................................................................................9
3.1 LCD Menu Structure..................................................................................................9
3.2 General Setting........................................................................................................11
Chapter 4 Web-based NMS Management........................................................22
4.1 login.......................................................................................................................22
4.2 Operation................................................................................................................22
Chapter 5 Troubleshooting .............................................................................37
Chapter 6 Packing List ...................................................................................38

1 / 41
Chapter 1 Product Outline
1.1 Outline
NDS357X IRD is DEXIN‟s new design which integrates demodulation, de-scrambler in one case
to convert RF signals into TS output after re-mux.
It is a 1-U case which supports 4 tuner inputs. The 4 CAMs/CIs accompanied can decrypt
programs input from encrypted RF, ASI and IP. The CAM requires NO unsightly external power
cords, cables, or additional remote control device.
BISS function is also embedded to descramble programs from any input.
Its pluggable structure design greatly facilitates the change of Tuner modules as needed.
To meet customers‟ various requirements, NDS357X is also equipped with 1 ASI and 1 IP input
for re-mux, and output with 2 ASI ports and IP port.
1.2 Features
4 DVB-S/S2 Tuner inputs (DVB-C, T/T2, Optional)
1 ASI & 1 IP (UDP) input for re-mux
One CAM can decrypt multiple programs from Tuners/ASI/IP
Support BISS descrambling
IP (1 MPTS & 8 SPTS) over UDP and RTP/RTSP output; ASI out
Support maximum 128 PID mapping per input
Pluggable and changeable demodulator modules
LCD display, Remote control and Firmware, web NMS management
Updates via web
Best quality and breakthrough price
1.3 Specifications

2 / 41
Input
4x RF (DVB-C, T/T2, S/S2 optional), F type
1×ASI input for re-mux, BNC interface
1xIP input for re-mux (UDP)
Tuner Section
DVB-C
Standard
J.83A(DVB-C), J.83B, J.83C
Input Frequency
47 MHz~860 MHz
Constellation
16/32/64/128/256 QAM
DVB-T/T2
Input Frequency
44MHz ~1002 MHz
Bandwidth
6/7/8 M bandwidth
DVB-S
Input Frequency
950-2150MHz
Symbol rate
2-45Msps
Signal Strength
- 65- -25dBm
Constellation
1/2, 2/3, 3/4, 5/6, 7/8 QPSK
DVB-S2
Input Frequency
950-2150MHz
Symbol rate
QPSK 1~45Mbauds;
8PSK 2~30Mbauds
Code rate
1/2, 3/5, 2/3, 3/4, 4/5, 5/6,
8/9, 9/10
Constellation
QPSK, 8PSK
Output
IP Output
1*MPTS & 8*SPTS over UDP,
RTP/RTSP.
100Base-T Ethernet interface
(unicast / multicast)
2×ASI
BNC interface
System
Local interface
LCD + control buttons
Remote
management
Web NMS Management
Language
English
General
Power supply
AC 100V~240V
Dimensions
482*300*44.5mm
Weight
3 kgs
Operation
temperature
0~45℃
1.4 Principle Chart
IP Output
ASI Output 1,2
MUX
IP
Tuner 4
ASI
CAM/CI 1
Tuner 3
Tuner 2
Tuner 1
CAM/CI 2
CAM/CI 3
CAM/CI 4

NDS357X IRD User‟s Manual
3 / 41
1.5 System Connection Sample
NDS357X Coaxial
Cable
NDS357X
Tuner
Modulator
RF
1 ASI
Tuner
1 ASI
TS
1 IP
1 IP
1.6 Appearance and Description
Front Panel Illustration:
1
LCD Display
2
NMS Port: connect to PC for device management;
DATA Port: for IP stream input & output
3
Indicators Area (Lock 1-4: they light up when the tuner signal are
properly connected.)
4
Up/Down/Left/Right Buttons
Enter Key for confirmation
Menu Key for backward
Lock Key
Rear Panel Illustration
1
CAM/CI Slots A & B (Applied to descramble tuner 1 & 2, ASI input
and IP input)
2
Tuner Input 1 & 2
3
CAM/CI Slots C & D (Applied to descramble tuner 3 & 4, ASI input

NDS357X IRD User‟s Manual
4 / 41
and IP input)
4
Tuner Input 3 & 4
5
ASI input port for re-mux
6
ASI mirrored output
7
Power switch/Fuse/Socket
8
Grounding

NDS357X IRD User‟s Manual
5 / 41
Chapter 2 Installation Guide
2.1 Acquisition Check
When user opens the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
NDS357X IRD 1pcs
User‟s Manual 1pcs
Tuner Cables (for loop through) 2 pcs
Power Cord 1pcs
If any item is missing or mismatching with the list above, please contact our company.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing modulator
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device's Installation Flow Chart Illustrated as following:
Connecting
Grouding
Wire and
Power
Cord
Acquisition
Check Fixing
Device Setting
Parameter Running
Device
Connecting
Signal Wire
2.2.2 Environment Requirement

NDS357X IRD User‟s Manual
6 / 41
Item
Requirement
Machine Hall Space
When user installs machine frame array in one machine hall,
the distance between 2 rows of machine frames should be
1.2~1.5m and the distance against wall should be no less
than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level
glasses for window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires
AC power 100-240V 50-60Hz. Please carefully check before
running.
2.2.3 Grounding Requirement
All function modules‟ good grounding is the basis of reliability and stability of devices.
Also, they are the most important guarantee of lightning arresting and interference
rejection. Therefore, the system must follow this rule.
Coaxial cables outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be
antirust.

NDS357X IRD User‟s Manual
7 / 41
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device‟s frame should be no
less than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding
wire should be as short as possible and avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device‟s grounding rod to frame‟s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC
power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS357X IRD, user should set the power switch to
“OFF”.
2.4 Signal Cable Connection
The signal connections include the connection of input signal cable and the connection of
output signal cable. The details are as follows:
2.4.1 NDS357X IRD Cables Illustration:

NDS357X IRD User‟s Manual
8 / 41
IP Input/output Cable Illustration:
Tuner Cable Illustration:
ASI Input/output Cable Illustration:

NDS357X IRD User‟s Manual
9 / 41
Chapter 3 Operation
The front panel of NDS357X IRD is the user-operating interface and the equipment can be
conveniently operated and managed according to the procedures displayed on the LCD:
Keyboard Function Description:
LEFT/RIGHT: Choose and set the parameters.
UP/DOWN: Modify activated parameter or paging up/down when parameter is inactivated.
ENTER: Activate the parameters which need modifications, or confirm the change after
modification.
MENU: Cancel current entered value, resume previous setting; Return to previous menu.
LOCK: Lock the screen/cancel the lock state. After pressing the lock key, the LCD will
display the current configuring state.
3.1 LCD Menu Structure
Initializing
IRD
Bitrate: 70.865Mbps
1 Status Alarm
Uptime
2 Input Sets 2.1 Tuner DVBS/S2
2.4 Tuner DVBS/S2
Tuner Parameters
Mux Program
Satellite frequency
LNB frequency
Symbol rate
LNB voltage
22K
Signal Lock
TS Lock
Parse Program
Select Program
(Same content with
‘
Tuner 1
’
above)
Input IP
Input Port
Multicast
IGMP Snooping
Service IP
2.5: ASI 2.5.1 TS Lock
2.5.2 Parse Program
2.5.3 Select Program
2.6 IP 2.6.1 IP Config
2.6.2 Mux Program TS Lock
Parse Program
Select Program
2.3 Tuner DVBS/S2
2.2 Tuner DVBS/S2
(Same content with
‘
Tuner 1
’
above)
(Same content with
‘
Tuner 1
’
above)

NDS357X IRD User‟s Manual
10 / 41
3 CI Card 3.1 Card A
3.2 Card B
3.1.1 Max Birate
3.1.2 Input TS Mode
3.1.3 Card Error Check
3.1.4 Parse Program
3.1.5 Descramble Program
3.1.6 Rom Version
3.1.7 Card Status
3.1.8 Descramble Error
(Same content with
‘
Card A
’
above)
3.3 Card C
3.4 Card D
(Same content with
‘
Card A
’
above)
(Same content with
‘
Card A
’
above)
8 System 8.1 Save Config
8.2 Load Saved CFG
8.3 Factory Reset
8.4 LCD Time-out
8.6 Lock Keyboard
8.7 Product ID
8.8 Language
5 TS Config
5.4 TSID
5.5 ONID
5.3 ASI out select
8.5 Key Password
7 Network 7.1 NMS IP
7.2 Subnet Mask
7.3 Gateway
7.4 MAC Address
7.6 Reset Password
7.5 Web NMS Port
5.2 TS output bitrate
6 IP Stream
6.4 Output Protocol
6.5 MPTS 1
6.3 Gateway
Data Enable
Null PKT Filter
Output IP
Output Port
Bitrate
6.1 Service IP
6.2 Subnet Mask
6.6 SPTS 1
6.13 SPTS 8
(SPTS 1-8 have the
same submenus with
‘
MPTS 1
’
above)
8.9 Version
5.1 TS Output mode
4 BISS Descrambling 4.1 BISS A
4.2 BISS B
4.1.1 Input TS Mode
4.1.2 Descrambler Key
4.1.3 SK
4.1.4 Word Mode
4.1.5 Burned Key
4.1.6 TS Lock
4.1.7 Parse Program
4.1.8 Desc Program
(Same content with
‘
BISS A
’
above)
4.3 BISS C
4.4 BISS D
(Same content with
‘
BISS A
’
above)
(Same content with
‘
BISS A
’
above)

NDS357X IRD User‟s Manual
11 / 41
3.2 General Setting
Switch on the device and after a few seconds‟ initialization, it presents start-up pictures as
below:
IRD: Device‟s name
Bitrate: xx.xxx Mbps indicates the current output bitrate.
Press LOCK key on the front panel to enter the main menu. The LCD will display the
following pages where user can configure the parameters for the device:
User could do all the settings according to the 8 directions displayed on the LCD. User can
press UP/DOWN buttons to specify menu item, and then press ENTER to enter the
submenus as below:
3.2.1 Status
Alarm: The alarm indicator will turn on if there is no signal inputting or outputting bit rate
overflows. User then can enter this menu to check the error type. Otherwise it shows the
„system is normal‟.
Uptime: It displays the working time duration of the device. It times upon power on.
Start up…
Start OK…
IRD
Bitrate: xx.xxx Mbps
Alarm
System is normal
Uptime
1 Day(s) 03:30:02
Main Menu
1 Status
2 Input Sets
3 CI Card
4 BISS Descrambling
5 TS Config
6 IP Stream
7 Network
8 System

NDS357X IRD User‟s Manual
12 / 41
3.2.2 Input Sets
NDS357X supports 4 tuners input, 1 ASI input and 1 IP stream input. Users can enter „Input
Sets‟to configure the tuner/ASI/IP parameters to receive the transport streams and select
programs to mux out via IP packages. It displays as below. (Taking DVB-S/S2 as example)
Tuner DVB-S/S2 (Submenus 2.1 –2.4)
Press ENTER key to enter „2.1 Tuner DVBS/S2‟(or 2.2/2.3/2.4) to configure the
corresponding tuner input according to rear panel. It displays as below:
Tuner Parameters:
Users can enter this menu to configure the tuner parameters separately to receive the tuner
programs.
Mux Program:
Users can parse the Tuner input program list and select programs to mux out in this menu.
NOTE: Multiplexed programs can only be output through IP (MPTS).
Tuner Parameters:
Satellite frequency
LNB frequency
Symbol rate
LNB Voltage
22K
Signal Lock
For checking signal status and quality etc
18V, 13v and 0v Optional
Input Sets
2.1 Tuner DVBS/S2
2.2 Tuner DVBS/S2
2.3 Tuner DVBS/S2
2.4 Tuner DVBS/S2
2.5 ASI
2.6 IP
Tuner DVB-S2
Tuner Para
Mux Prog

NDS357X IRD User‟s Manual
13 / 41
ASI (Submenus 2.5)
Users can parse ASI input programs and select program(s) to mux out under this menu. The
operating method is same with what explained above.
IP(Submenus 2.6)
Press ENTER key to enter „2.6 IP‟, it displays as below:
IP Config:
Users can enter this menu to configure IP parameters according to the IP source to receive
the IP programs.
Mux Program
TS Lock
Parse Program
Select Program
TS Locked
Bitrate: 4.040 Mbps
Searching Program
Get 7 Programs
For reading the input
bitrate
For reading the number
of programs from
Tuner 1 (or 2)
Mux Program (0/7)
1: CCTV 1 X
„1/7‟represents there are all 7 programs in the list and 1 program has been selected to mux out through ASI.
Mux Program (0/7)
1: CCTV 1 [←]
Mux Program (0/7)
1: CCTV 1 [→]
Mux Program (1/7)
1: CCTV 1 √
Process of selecting programs to
output through front panel:
[←]: to cancel program output;
[→]: to output the program
“√”: a symbol indicating the
corresponding program has been
selected to output;
“X”: a symbol indicating the
corresponding program has not
been selected to output
Press ENTER key
Press RIGHT/LEFT
key to shift arrow
Press ENTER key to
confirm
ASI
TS Lock
Parse Program
Select Program
IP
IP Config
Mux Program

NDS357X IRD User‟s Manual
14 / 41
Mux Program:
Users can parse the IP input program list and select programs to mux out in this menu. The
operating method is same with what explained above.
3.2.3 CI Card
NDS357X IRD supports 4 CI cards (Card A, B, C and D) to descramble encrypted programs
from RF, ASI or IP. Users can press ENTER key to enter „3 CI Card‟to configure the 4
cards respectively.
Press ENTER key to enter Card A (or Card B/C/D):
Max Bit rate
CI Max Bitrate options range from 48-108Mbps. Move the triangle to select a value as
Off, V2 and V3 Optional
IP Config
Input IP
Input Port
Multicast
IGMP Snooping
Service IP
Mux Program
TS Lock
Parse Program
Select Program
CI Card
Card A
Card B
Card C
Card D
Card A
Max Bitrate
Input TS Mode
Card Error
Parse Program
Descra ProgRom Version
Card Status
Descramble Error

NDS357X IRD User‟s Manual
15 / 41
principle: Actual Input Bitrate≤ Max Bitrate≤CI Max decrypting capacity
Input TS Mode
NDS357X has 6 signal sources: Tuner 1-4, ASI, and IP. One CI card can applied to
descramble one channel input signal from the 6 signal sources. „Skip CI card‟means to skip
the card which is used for FTA stream.
NOTE: Card A & B are designed to descramble tuner 1 & 2, ASI input and IP input,
while card C & D A are designed to descramble tuner 3 & 4, ASI input and IP input.
Card Error Check
Users can decide whether to enable or disable the card error check function in this menu.
Parse Program
Users can read the quantity of programs parsed from the de-scrambled channel.
Descramble Program
Users can select program(s) from the searched out programs to descramble. The quantity to
be descrambled depends on the CAM/CI performance you apply to.
Max Bitrate
►48 Mbps
Input TS Mode (1/5)
►Skip CI Card
Tuner 1
Tuner 2
ASI
IP
Card Error Check
►Enable
Searching Program
Get 8 Programs
►1 CETV 1 √
2 CCTV 4A X

NDS357X IRD User‟s Manual
16 / 41
Rom Version/Card Status/Descramble Error
Users can read the other info about the CI card in the following menus.
3.2.4 BISS Descrambling
NDS357X IRD supports also BISS to descramble encrypted programs from RF, ASI or IP.
Users can enter „4 BISS Descrambling‟to configure the 4 BISS respectively.
Press ENTER key to enter BISS A (or BISS B/C/D):
Input TS Mode
NDS357X has 6 signal sources: Tuner 1-4, ASI, and IP. One BISS can be applied to
descramble one channel input signal from the 6 signal sources. „Skip BISS‟means to skip
the card which is used for FTA stream.
Rom Version
4.4.5.0
Card Status
Normal
Descramble Error
Normal
CI Card
BISS A
BISS B
BISS C
BISS D
BISS A
Input TS Mode
Descrambler Key
SK
Word Mode
Burned Key
TS Lock
Parse Program
Desc Program

NDS357X IRD User‟s Manual
17 / 41
NOTE: BISS A & B are designed to descramble tuner 1 & 2, ASI input and IP input,
while BISS C & D A are designed to descramble tuner 3 & 4, ASI input and IP input.
Descrambler Key/SK/Word Mode/Burned Key
Users need to input keys to descramble programs as per the BISS scrambling side which
usually is DVB-S/S2 modulator.
The descrambling principle is as following chart:
Modulating Side (BISS SCR)
Receiving Side (BISS DESCR)
Digit (0x----)
Mode 1+SW Data
Mode 1+Descrambler Key
12
Mode E+ESW Data + Device
Mode E + Descrambler Key + Burned Key
16
Mode E+ESW Data + Input ID
Mode E + Descrambler Key + SK
14
TS Lock
Users can read the real-time bitrate of the corresponding channel.
Parse Program
Users can read the quantity of programs parsed from the de-scrambled channel.
Descramble Program
Users can select program(s) from the searched out programs to descramble.
Input TS Mode (1/5)
►Skip BISS
Tuner 1
Tuner 2
ASI
IP
Searching Program
Get 7 Programs
TS Locked
Bitrate: 34.662 Mbps
Table of contents
Popular Receiver manuals by other brands

Quantum
Quantum FreeWire FW7Q operating instructions

TechniSat
TechniSat TECHNISTAR S6 How-to

Nice
Nice FLOX1 installation instructions

Kenwood
Kenwood R-5000 instruction manual

Bandini Industrie
Bandini Industrie GI.BI.DI. DOMINO DRC4334 Instructions for installations

Harman Kardon
Harman Kardon AVR 435 Service manual