1.5 STANDARD FEATURES continued...
•Output Isolated from Earth Ground. Isolation is provided between the output circuit and transducer ground,
simplifying installations.
•Dual Calibration. Allows two calibration settings. Dual calibration example applications:
a. One set of transducers operating in a wide tension range. Dual calibration and dual meter scale is used to
enhance the resolution of indicated tension.
b. One set of transducers that may be subject to two different wrap angles or web paths. In this case a dual
meter scale may, or may not, be required.
•Screw Clamp Mating Terminal Block Connector. Allows easy connection of external wiring.
•Status LED. Green LED flashes to verify ZERO and CALIBRATION, and indicates presence of power and
proper circuit operation. If power is on and no faults are detected, LED will be on solid. LED will flash
momentarily to indicate acceptance of a ZERO or CALIBRATION button push.
•Short Circuit Protection. Unit automatically protects transducer excitation and tension output from short
circuits or excessive loading. If a short circuit is detected, the unit will safely shut that portion of the circuit
off until the fault is cleared. Unit automatically recovers when the fault is removed.
1.6 OPTIONS
SOME OF THESE OPTIONAL FEATURES REQUIRE CONFIGURATION OR EXTERNAL WIRING.
REFER TO SECTION 2.4 FOR INSTALLATION INSTRUCTIONS AND SECTION 2.7 FOR WIRING.
•0-100 Microamp Output (100M). 0-100 microamp output to drive tension meter. Jumper selectable.
•25% Calibration Weight (25CW). Used when 25% of full scale calibration weight is desired instead of the
standard 10% calibration weight. Jumper selectable to 10% or 25%.
•230 Volt Input (230). 230Volt, 50 Hz AC power input. Ti17C only.
n WARNING: Ti17C models are designed for single phase AC operation only. Do not connect them across
three phase lines or to three phase circuits to prevent product damage and potential hazard.
•Auto Zero (AZ). Unit will auto zero the output on each power up. Jumper selected on or off.
•Cover (COV). Cover restricts access to board and provides complete enclosure. V version only.
n WARNING: Ti17C models require the full case and properly installed cover for CE approval. Operating
without a properly installed cover as directed in section 2.3 invalidates CE approval and may pose a shock
hazard.
n WARNING: Ti17C and Ti18C models require the full case and properly installed cover for UL/cUL
Listing. Operating without a properly installed cover as directed in section 2.3 invalidates UL/cUL Listing
and may pose a shock hazard.
•DIN Rail Clip (DRC). To be used with 35 mm DIN rail. V version only.
•4 to 20mA Output (I420). Isolated 4-20 mA current output, used in place of isolated 0 to +10V output.
Jumper selected between 0 to +10V and 4-20mA.
•Tension Limit Switch (TLS). An open collector output actuates at a pre-set adjustable trip point. Can be used
as a web break detector, or high tension warning. A red LED activates on the front panel when TLS is
triggered. Low and high trip points are independently adjustable. Trigger delay is adjustable.
n WARNING: TLS must not be used to switch hazardous voltages. It is rated for 24Vdc Maximum.
Maximum current is 250mA. Ensure a proper dropping resistor is used to limit current to 250mA or less.
Excess current or voltage can permanently damage the product and may pose a shock or fire hazard.
• Extended Range (XRE). 10 Vdc excitation for Extended Range transducers. Allows measurement of much
lower tension than usual. Transducers must also have the XR option. Jumper selectable to 5Vdc or 10Vdc.
4