91000749 A
Step Five: Install peripheral cabling
You can connect printers, terminals, modems (or any other standard EIA-
232 device to be controlled by applications on the computer) to the
EPC/CON-16 concentrator by installing a cable between the peripheral
and the concentrator.
On the peripheral end of the cable, the cable connector depends on the
requirements of the peripheral. The EPC/CON-16 (or PORTS/Xem mod-
ule) end of the cable must fit either an RJ-45 or DB-25 connector,
depending on the model you have.
The pin assignments for each type of EPC/CON-16 connector are as fol-
lows:
DB-25 Pin assignments
RJ-45 pin assignments are shown on the back.
RJ-45 Pin Assignments
Refer to the CD-ROM for more detailed cabling information.
What Next?
At this point the hardware installation for your EPC/X system is com-
plete. However, since the EPC/X adapter and the EPC/CON-16 concen-
tratorsmust have softwaredownloaded to their internal RAM before they
become functional, you must next install the software drivers for your
operating system.
• Read the instruction booklet for the CD-ROM that came with your
system for instructions on installing software.
• View the on-line documentation on the CD-ROM for more informa-
tion about your EPC/X system.
The Digi logo and AccelePort are registered trademarks ofDigi International. EPC/X,
EPC/CON-16, PORTS/Xem PORTS/8em, PORTS/16em, Modem/Xem, Modem/4em, and
Modem/8em are trademarks of Digi International.
All other brand and product names are trademarks of their respective holders.
© Digi International Inc., 1998; All Rights Reserved; http://www.dgii.com
Information in this document is subject to change without notice and does not represent a
commitment on the part of Digi International.
Digi provides this document “as is”, without warranty of any kind, either expressed or
implied, including, but not limited to, the implied warranties of fitness or merchantability
for a particular purpose. Digi may make improvements and/or changes in this manual or in
the product(s) and/or the program(s) described in this manual at any time.
This product could include technical inaccuracies or typographical errors. Changes are peri-
odically made to the information herein; these changes may be incorporated in new editions
of the publication.
AccelePort EPC/X System
EPC/X PCI Host Adapter
EPC/CON-16 Concentrator
Hardware
Installation Guide
Introduction
An AccelePort®EPC/X™system consists of an EPC/X host adapter cou-
pled with EPC/CON-16™concentrators from which EIA-232 peripheral
devices such as printers, terminals or modems can be cabled and con-
trolled. The adapter has two lines that can each support one or more con-
centrators. Multiple concentrators can be linked in a chain, and Digi
PORTS/8em™, PORTS/16em™, Modem/4em™, and/or Modem/8em™
modules can be added to a concentrator to expand the number of ports
available.
Figure 44. Example EPC/X setup
This installation guide describes how to plan your setup and install the
EPC/X host adapter and concentrator hardware.
Signal Description Pin
GND Chassis Ground 1*
TxD Transmitted Data 2
RxD Received Data 3
RTS Request To Send 4
CTS Clear To Send 5
DSR Data Set Ready 6
SG Signal Ground 7
DCD Data Carrier Detect 8
DTR Data Terminal Ready 20
RI Ring Indicator 22
* Chassis Ground is also available on the
connector shell
Signal Description Pin
RI Ring Indicator 1
DSR Data Set Ready 2†
RTS Request To Send 3
GND Chassis Ground 4
TxD Transmitted Data 5
RxD Received Data 6
SG Signal Ground 7
CTS Clear To Send 8
DTR Data Terminal Ready 9
DCD Data Carrier Detect 10
† Pin 2 can be configured for DCD (through Digi
software) if you want to connect using an 8 pin
connector
Step One: Plan your setup
An EPC/X system can be set up in a variety of ways. Before you start
your installation, be sure of the following:
Number of components. You can connect up to fourteen concentrators
and Xem modules onto one EPC/X host adapter (using both lines). It
is a good idea to balance the number of connections on each line.
Having 12 concentrators and modules on one line, and 2 on the other,
for example, may not make the best use of line resource.
Location of components. Using the cables that come with the product,
concentrators can be located up to ten feet apart. (The daisy-chain
cablethat comes with each Xem module allowsit to be stacked on top
of the concentrator to which it is attached via the EBI connector.)
If your installation calls for greater distances between concentrators,
you can use twisted pair cabling in a maximum cumulative length of
up to 2000 feet (600 meters) from the host adapter.
Note: The length of twisted pair cabling affectsthe maximum data
transfer rate that can be expected over the cable. The longer
the length, the lower the rate. To maintain a baud rate of 10
Mbaud, the maximum cumulative twisted pair cable length
cannot exceed 30 feet (9 meters).
You can also use fiber optic cable (a special fiber optic conversion
option is available from Digi) that will allow a distance of up to 1.2
miles (2000 meters) from the adapter.
For even greater distances, you can attach a synchronous modem
directly to the adapter, and remotely locate concentrators and Xem
modules to a second synchronous modem.
Cabling. Before beginning the installation, be sure that you have the
cables that you will need for the distances between concentrators, as
well as cables for the peripherals that you will be attaching to the con-
centrators and Xem modules. EPC/X system concentrators and
PORTS/Xem modules are available with RJ-45 or DB-25 connectors
for peripheral cabling. You will need to be sure that you have cables
of the correct length and with the right connectors to properly attach
the devices you want to use with each concentrator or Xem module.
Power Requirements. Each EPC/CON-16 concentrator (and
Modem/Xem module) requires its own power supply. Before pro-
ceeding with installation, you should verify that adequate line power
is available where each concentrator (and Modem/Xem) will be
installed. Note that PORTS/Xem modules do not require power sup-
plies when attached to an EPC/CON-16 concentrator.
Additional information about the options available with the EPC/X
system, such as specifications and cabling details, is provided on the
CD-ROM that is packaged with the host adapter.
Step Two: Install the EPC/X PCI host adapter
Before installing the EPC/X host adapter, you should do the following:
• Wear an ESD wrist strap to ground yourself while handling the
adapter. If one is not available, discharge static electricity from your
body by touching an unpainted metal surface, such as the computer’s
chassis, prior to handling the adapter.
• Record the adapter serial number, which will enable Digi to provide
you with better service, should the need arise.
The serial number label has this general format: S/N: (S) XXX XXXXX
• Unplug power from the PC.
1. Remove the computer’s cover.
2. Locate an available PCI slot in your computer and remove the slot
plate.
3. Insert the adapter into the slot and screw the endplate to the computer
chassis. The endplate must be screwed into the computer chassis to
remain in compliance with Part 15 of FCC rules.
4. Replace the computer’s cover.
5. Attach an EIA-422 cable to the connector of each line you will use on
the adapter.
Step Three: Install concentrators and add-ons
1. Position concentrators and Xem modules (if any) at the location you
have prepared according to the plan you developed in Step One.
2. Attach the cable from line l on the adapter to the connector labelled
HOST ADAPTER on the first concentrator of the chain that is to be
connected to Line 1.
Figure 45. Side Panel of EPC/CON-16 module
If you are cabling multiple concentrators together, attach another
cable to the REMOTEconnector of the first concentrator. Connect this
cable to the HOST ADAPTER connector of the second concentrator.
Continue cabling until all concentrators in the chain are connected.
3. Install a terminator plug in the REMOTE connector of the last concen-
trator in the chain.
4. Repeat steps 2 and 3 for Line 2 on the adapter (if you are using it).
5. To cable PORTS/Xem or Modem/Xem modules to the EBI bus of a
concentrator, attach one end of an EBI cable to the EBI OUT connec-
tor on a concentrator and the other end to the EBI IN connector on the
add-on module. Continue similarly using the EBI IN and EBI OUT
connectors on the add-on modules until all the add-ons for a concen-
trator are cabled together.
6. Attach power supplies to the concentrators (and Modem/Xem mod-
ules).
7. Turn on power to the unit(s).
Step Four: Set the node numbers
Each concentrator must have a unique node number so the adapter can
recognize it on the chain. In general, you should set the node number of a
concentrator according to its relative position in the chain. For example,
the concentratorclosest tothe adapter would be node 1, the secondwould
be node 2, and so on. To set the node number, do the following:
1. Wait until you see P1 displayed on the front panel of the unit (about
30 seconds after you power on the unit). This indicates that the
Power-on Self Test has successfully completed.
2. Press the right arrow button once to display the current node number.
(1n is the default.)
3. Press the left arrow button to increment the node number. Node num-
bers go up to 8n and then return to 1n.
4. To save the node number currently displayed on the front panel, press
the right arrow button once. If the number was successfully saved to
EEPROM, the display will read Pn.

This manual suits for next models

1

Other Digi Host Adapter manuals

Digi Neo Manual

Digi

Digi Neo Manual

Digi Neo Series Parts list manual

Digi

Digi Neo Series Parts list manual

Digi AccelePort Xe Series Manual

Digi

Digi AccelePort Xe Series Manual

Digi AccelePort Xe EIA-232 Manual

Digi

Digi AccelePort Xe EIA-232 Manual

Digi AccelePort Xr 920 EIA-232 Manual

Digi

Digi AccelePort Xr 920 EIA-232 Manual

Digi EIA-232 Manual

Digi

Digi EIA-232 Manual

Digi AccelePort Xr EIA-422 Manual

Digi

Digi AccelePort Xr EIA-422 Manual

Digi AccelePort Xe EIA-422 Manual

Digi

Digi AccelePort Xe EIA-422 Manual

Digi AccelePort r Series Manual

Digi

Digi AccelePort r Series Manual

Popular Host Adapter manuals by other brands

HighPoint RocketRAID 264x user guide

HighPoint

HighPoint RocketRAID 264x user guide

MCC IPort MIIC-201D/U user guide

MCC

MCC IPort MIIC-201D/U user guide

ATTO Technology Low-Profile SAS Host Adapter H308 Installation and operation manual

ATTO Technology

ATTO Technology Low-Profile SAS Host Adapter H308 Installation and operation manual

Adaptec AHA-1540CP installation guide

Adaptec

Adaptec AHA-1540CP installation guide

ATTO Technology iPBridge 2600 Installation and operation manual

ATTO Technology

ATTO Technology iPBridge 2600 Installation and operation manual

Icy Box IB-550StUS2-B-BL user manual

Icy Box

Icy Box IB-550StUS2-B-BL user manual

HP SC44Ge Quickspecs

HP

HP SC44Ge Quickspecs

ATTO Technology ExpressSAS R608 RAID Installation and operation manual

ATTO Technology

ATTO Technology ExpressSAS R608 RAID Installation and operation manual

Sonnet Tempo SATA EDGE ExpressCard/34 quick start guide

Sonnet

Sonnet Tempo SATA EDGE ExpressCard/34 quick start guide

Adaptec AHA-1540C installation guide

Adaptec

Adaptec AHA-1540C installation guide

CMD CBI-1010 user manual

CMD

CMD CBI-1010 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.