Digitroll XeedSystem User manual

THE
SEED MONITORING SYSTEM
ISOBUS application
USER MANUAL

Copyright information
2 |ISOBUS application – User manual for XeedSystem v1.2.3
Copyright information
© 2018 Digitroll Kft.
All rights reserved. No part of this publication may be reproduced, distributed, or transmitted
in any form or by any means, including photocopying, recording, or other electronic or
mechanical methods, without the prior written permission of the copyright owner, except in the
case of brief quotations embodied in critical reviews and certain other noncommercial uses
permitted by copyright law. For permission requests, write to the publisher, addressed
“Attention: Permissions Coordinator” at the address below.
Copyright owner:
Digitroll Ltd. Bánomkerti st. 63.
Hajdúszoboszló 4200, Hungary
E-mail:
Webpage:
www.digitroll.hu
Document:
Name: XeedSystem (v1.2.3) ISOBUS application User manual
Last modification: 2019.11.08
Printed in the EU.

Copyright information
ISOBUS application – User manual for XeedSystem v1.2.3
|3
Table of contents
Copyright information __________________________________ 2
1. System installation ________________________________ 4
2. Main screen ______________________________________ 7
2.1 Legends __________________________________________ 7
2.2 Errors on the main screen ____________________________ 7
2.3 Alerts ____________________________________________ 8
2.4 Working position ___________________________________ 9
2.5 Area _____________________________________________ 9
2.6 Confirm performance _______________________________ 9
3. Settings ________________________________________ 10
3.1 Seed settings _____________________________________ 10
3.2 Fertilizer settings __________________________________ 11
3.3 System diagnostic _________________________________ 12
4. System settings __________________________________ 13
4.1 System overview __________________________________ 14
4.2 Machine settings __________________________________ 14
4.2.1 Speed calibration ____________________________________ 15
4.3 Distributor binding ________________________________ 15
4.4 Alarm settings ____________________________________ 16
4.4.1 Seed alarms _________________________________________ 16
4.4.2 Fertilizer alarms _____________________________________ 16
5. About __________________________________________ 17

System installation
4 |ISOBUS application – User manual for XeedSystem v1.2.3
1. System installation
The system installation’s first step.
The summary of the detected device’s
list can be seen here.
Press the
Next button
to
continue the installation.
Press the
Refresh button
to
refresh the detected device’s
list.
Press the
Reset button
to
perform a device reset.
The installation’s second step.
On this page the distributor head
numbers must be assigned to each X-
LiNE Module.
Use the
Back or Next
button
to go back or
continue the installation.
Use the paging button
to page through the
device’s list.
The installation’s third step.
The applied seed’s attributes must be
set for the best seed monitoring.
Press the Enter button to
access to the seed alarms
settings.
Use the
Back or Next
button
to go back or
continue the installation.

System installation
ISOBUS application – User manual for XeedSystem v1.2.3
|5
On the seed alarms settings the under
and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the
Back button
to go
back to the seed settings.
Press the
Reset button
to reset
the alarm settings.
The system installation’s fourth step.
The applied fertilizer’s attributes must be
set.
Press the Enter button to
access to the seed alarms
settings.
Use the
Back or Next
button
to go back or
continue the installation.
On the fertilizer alarms settings the
under and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the
Back button
to go
back to the fertilizer settings.
Press the
Reset button
to reset
the alarm settings.

System installation
6 |ISOBUS application – User manual for XeedSystem v1.2.3
The installation’s final step.
Press the “Start using XeedSystem” to
finish the installation and start using the
system.
Press the
Back button
to go
back to the fertilizer settings.

Main screen
ISOBUS application – User manual for XeedSystem v1.2.3
|7
2. Main screen
The ISOFLOW application’s main
screen.
Every orange rectangle represents a
seeder distributor head.
Every blue rectangle represents a
fertilizer distributor head.
The little squares inside the orange/blue
rectangles represent the sensors.
Different colors of the squares mean
different statuses. (see legend)
2.1 Legends
To access to the legends screen, press
the
Legends button
.
The legends screen helps to identify
every possible error and statuses on
the main screen.
2.2 Errors on the main screen
Every kind of error may appear on the
main screen (main screen).
To identify the different errors, check
the error list or the details screen.
By pressing the number of the
distributor heads, at the left side of the
distributor rectangle, the given
distributor head’s details screen can be
seen.

Main screen
8 |ISOBUS application – User manual for XeedSystem v1.2.3
2.3 Alerts
Every error occurrence causes an alert
screen.
The alert screen draws the operator’s
attention every time a new error occurs
in the system.
On this screen the occurred errors can
be seen in priority order, and the errors
can be managed, in terms of future
alerts.
Press the
Confirm button
to close
the alert screen.
Press the
Error list button
to see every error in a list,
and to get to know more
about the errors.
Press the
Ignore button
to ignore
the same errors on the given
sensor.
Press the
Ignore all button
to ignore every alert in the
future.
The Ignore and Ignore all buttons only ignore the alerts screen! The errors will be displayed
on the main screen and will appear in the error list as well.
On the error list the list of the errors can
be seen.
This screen’s purpose is to give more
information about the occurred errors
and from their location.
At the top of the screen a summary can
be seen about the Active and
disappeared errors.
The active errors are marked with a “!”
(exclamation mark) and sorted to the top
of the list.
The disappeared errors are marked with
an “x”.
The error screen can be accessed from the Alert screen, or
from the main screen by pressing one of the
Error list buttons.

Main screen
ISOBUS application – User manual for XeedSystem v1.2.3
|9
2.4 Working position
At the top middle of the main screen a working position icon can be seen. This
icon functions as a button as well.
If the machine is in working position but the system reports lifted working
position, with this quick button, the working position’s interpretation can be
changed.
2.5 Area
For precise area measurement it is crucial to set the working width and to
calibrate the speed properly.
These options can be set on the machine settings screen, which can be
accessed from the settings, or by pressing the area icon on the main screen.
By holding the area button (at least for 2 secs), the sowed area can be set to zero.
Press the
Back button
to
return to the main screen.
Press the “Go to Machine Settings” to
access the machine settings screen.
2.6 Confirm performance
In practice it might occur that the machine’s performance – application rate by
rows – is not consistent, there can be bigger differences between the rows.
If the operator is aware of this characteristic of the machine and wants to ignore
these bigger differences between, it can be done with the „
Confirm
performance” button
. Therefore, the actual machine performance will be accepted as
consistent.
To cancel the performance confirm, press the
Confirm performance button
again.

Settings
10 |ISOBUS application – User manual for XeedSystem v1.2.3
3. Settings
The settings can be accessed by pressing the
Settings button
on the main
screen.
From the settings screen various
options can be accessed.
Press the
Enter button
to
enter any of the setting’s
submenu.
Press the
Home button
to return to the main
screen.
3.1 Seed settings
The seed settings can be modified here.
Press the
Reset button
to
reset every seed option.
Press the
Home button
to return to the main
screen.
Press the
Back button
to
return to the settings
screen.

Settings
ISOBUS application – User manual for XeedSystem v1.2.3
|11
On the seed alarms settings the under
and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the
Back button
to go
back to the seed settings.
Press the
Home button
to return
to the main screen.
Press the
Reset button
to reset
the alarm settings.
3.2 Fertilizer settings
The fertilizer settings can be modified here.
Press the
Reset button
to
reset every seed option.
Press the
Home button
to return to the main
screen.
Press the
Back button
to
return to the settings
screen.
On the fertilizer alarms settings the
under and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the
Back button
to go
back to the fertilizer settings.
Press the
Home button
to
return to the main screen.
Press the
Reset button
to reset
the alarm settings.

Settings
12 |ISOBUS application – User manual for XeedSystem v1.2.3
3.3 System diagnostic
To access the diagnostic screen press the
Enter button
next to the System
diagnostic label on the settings screen.
Upon opening the system diagnostic,
the system warns the operator, that the
diagnostic process is about to stop the
seed monitoring.
Press the
Confirm button
to accept this condition,
to continue to the
diagnostic page.
Press the
Cancel button
to return to the previous
page.
The diagnostics of XeedGATE and the
related information can be found here.
Use the Back and Next
buttons to see the other
device’s diagnostics.
Press the
Home button
to
return to the main screen.
The diagnostics of X-LiNE modules and
the related information can be found
here.
Use the
Back and Next
buttons
to see the other
device’s diagnostics.
Use the paging buttons to
page through the
device’s list.
Press the
Home button
to
return to the main screen.

System settings
ISOBUS application – User manual for XeedSystem v1.2.3
|13
The diagnostics of seed sensors and the
related information can be found here.
Use the
Back and Next
buttons
to see the other
device’s diagnostics.
Use the paging buttons to
page through the
device’s list.
Press the
Home button
to
return to the main screen.
The diagnostics of fertilizer sensors and
the related information can be found
here.
Use the
Back and Next
buttons
to see the other
device’s diagnostics.
Use the paging buttons to
page through the
device’s list.
Press the
Home button
to
return to the main screen.
4. System settings
To access the System settings screen press the
Enter button
next to the
System setup label on the settings screen.
From the system settings many settings
can be accessed related to the
machine and it’s properties.
Press the
Back button
to
return to the Settings screen.
Press the
Home button
to
return to the main screen.

System settings
14 |ISOBUS application – User manual for XeedSystem v1.2.3
4.1 System overview
The summary of the detected device’s list can be seen here.
Press the
Home button
to
return to the main screen.
Press the
Back button
to
return to the System settings
screen.
Press the
Refresh button
to
refresh the detected device’s
list.
Press the
Reset button
to
perform a device reset.
The device reset resets the XeedGATE and erase all settings. After device reset the
system must be installed again from the beginning.
If there are changes in the
system structure and the
system notices it after
pressing the refresh button,
the next button turns to active, enabling
to update the system’s parameters
according to the new structure, through
a quick setup.
Moreover, the system gives a warning:
System is changed.
4.2 Machine settings
The working width and the speed
calibration can be modified here.
For precise area measurement it is
crucial to set the working width and to
calibrate the speed properly.
The machine settings also can be
accessed from the main screen by
pressing the area icon.

System settings
ISOBUS application – User manual for XeedSystem v1.2.3
|15
4.2.1 Speed calibration
The seeder’s speed calibration can be
modified or set here.
Press the
Back button
to
return to the machine settings
screen.
Press the
Home button
to
return to the main screen.
4.3 Distributor binding
The binding of the X-LiNE modules and
distributor heads can be modified here,
that were specified during the setup
flow.
Use the
paging buttons
to page through the
device’s list.
Press the
Back button
to
return to the system settings
screen.
Press the
Home button
to
return to the main screen.
The binding of the sensors can be
modified here
Use the
paging buttons
to page through the
device’s list.
Press the
Back button
to
return to the system settings
screen.
Press the
Home button
to
return to the main screen.

System settings
16 |ISOBUS application – User manual for XeedSystem v1.2.3
4.4 Alarm settings
The seed and fertilizer alert settings can
be accessed from this screen.
Press the reset button to
restore every alert settings to
the default option.
Press the
Back button
to
return to the system settings
screen.
Press the
Home button
to
return to the main screen.
4.4.1 Seed alarms
On the seed alarms settings the under
and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the reset button to
restore the seed alarm settings
to the default option.
4.4.2 Fertilizer alarms
On the fertilizer alarms settings the
under and overflow limits can be set.
The alarm delay can be set in seconds,
for how long the errors (blockage,
under/overflow) should persist
continuously before the system
indicates it.
Press the reset button to
restore the seed alarm settings
to the default option.

About
ISOBUS application – User manual for XeedSystem v1.2.3
|17
5. About
Press the
About button
on the settings screen to
access to the about
screen.
This page provides basic information
about the legal and Digitroll Ltd. from,
such as accessibility, website.
Other manuals for XeedSystem
1
Table of contents
Popular Measuring Instrument manuals by other brands

Sekonic
Sekonic SPECTROMASTER C-7000 Startup guide

BUILD TEST SOLUTIONS
BUILD TEST SOLUTIONS BTS-Pulse 2.0 Instruction Manual and Safety Guidelines

SATO
SATO S100WP-01 instruction manual

National Instruments
National Instruments USB-5683 Getting started guide

Altronics
Altronics Redback A 2067 instructions

Dytran
Dytran 3088C operating guide