DIGM Technology GSM-0308WPC User manual

GSM WATER PUMP CONTROLLER AND
MONITORING SYSTEM
Model: GSM-0308WPC

GSM-0308WPC User Manual
2|Page
TableofContents
Application………..……………………………………………...…………………………………………3
Instructions…………….……………………………………………………………………………………4
InstallationDiagram….……………………………………………………………………..………….5
DeviceDesign…………..………………………………………………………….………………………5
TechnicalParameter..…………………………………………………………………………………..6
SetupInstruction………………………………………………………………………………………….6
1Administrator
1.1TemporaryAdministratorPrivilege……………………………………………………………………………………….6
1.2ChangingaPassword…………………………………………………………………………………………………………….6
1.3AddanAdministratorNumber……………………………………………………………………………………..……….7
1.4EnquirytoAdministratorNumbersinthelist………………………………………………………………………..7
1.5DeleteAdministratorNumberinthelist……………………………………………………………………………….8
1.6EnquirySignalStrength………………………………………………………………………………………………………...8
1.7TimeScheduletosendSMSRemindertotheAdministrator……………………………………………..….8
2SystemAlarmAlertProgramming
2.1CallAlertForTriggerTypeAlarm.………..……………………………………………………………….……………….9
3. PumpActivation.………..……………………………………………………………………………………….……………….9

GSM-0308WPC User Manual
3|Page
Applications:
Thisproductissuitableforwaterpumpcontrol,reservoircontrol,aquariumetc.CanuseSMSto
remotelyEnquiryfor,TextContentforAlarmAlert/CallAlarmAlert.

GSM-0308WPC User Manual
4|Page
Instructions:
Afterconnecttotheunit,connecttheinputtoyourtriggerunitondrycontactattheobject
youneedtomonitor.OncethedevicetriggerwillSMS/phonecalltoinformyou.Maximum
5groupadministratorcanbesetuptoreceivealarmalerts.
4simplestepstousethedevice:
1. InserttheSIMcard
2. Pluginthepowercableintothepowersupplysocket
3. SwitchontheOn/Offswitch
4. Afterthedevicestarts,makeacalltothedevice(calltheSIMcardphonenumber)
Note:Whenheara"~di"sound,youcandeterminetheequipmenthasbeenstart
successfully.
Whenitreplyasfollows,itisreadytouse.

GSM-0308WPC User Manual
5|Page
InstallationDiagram
DeviceDesign

GSM-0308WPC User Manual
6|Page
TechnicalParameter
• PowerSupply:SinglePhase220V‐240V50/60Hz
• GSMFrequency:GSM900/1800Mhz(OptionalGSM850/900/1800/1900Mhz)
• DevicePower:<2W
• BackupBattery:7.4V/600mAHLithiumPolymerBattery
• MaximumLoadForControl:NO:10A/277VAC,NC:12A/125VAC
• RemoteMonitoringDistance:GSMnetworkcoveragearea
• PhysicalCasingDimension:180mmx140mmx60mm
• EnclosureIPRating:IP65
SetupviaSMSCommand
1.Administrator
1.1TemporaryAdministratorPrivilege:
*100*AAAAAA#
SettingupaTemporaryAdministratorPrivilegeforProgrammingMode:
AAAAAA=6DigitsPassword
DefaultPassword=123456
Byusingthiscommando,youwillobtainadministratorprivilegefor10Minutes.
Thatmeansyoucandoallprogrammingwithinthose10Minutes.
Ifyouaddyourtel.no.intheadministratorlist,youdonotneedthisfunctionanymore.
Ifanotherusessamecommandowithinthe10Minutes,thenyouwillloseyourAdministrator
privilege.
Alltel.no.ontheAdministratorlisthavefullcontrolovertheunitatalltime.
1.2ChangingaPassword:
*100*AAAAAA*BBBBBB#
Changethepassword.
AAAAAA=6CharacterOldPassword
BBBBBB=6CharacterNewPassword.
Atthesametime,itwillgettheAdministratorPrivilege.
Example:Send*100*123456*obs123#,thesystemwillchangetheadmintoobs123

GSM-0308WPC User Manual
7|Page
1.3AddanAdministratorNumber
*101*A*BBBBBB#
AddadministratorstotheAdministratorList
A=Administratorno‐(1–5)
BBBBBBBB=Tel.no.ofnewadministrator.
YoucanaddaMinimumof3digitsandamaximumof20digits.
Example:Send*101*5*13812512456#,Systemwillset13812512456asAdmin5
Send*101*3*123456#,Systemwillset123456asAdmin3
1.4EnquirytotheAdministratorNumbersinthelist
*102#
Checkadministratorlist
Itwillreplywithafulllistofalladministratorsonthelist.

GSM-0308WPC User Manual
8|Page
1.5DeleteAdministratorNumberinthelist:
*103*A#
Deletingadministratortel.no.onthelist
A=administratorno.(1–5)
Example:Send*103*5#,thesystemwilldeletetheAdmin5
1.6EnquirySignalStrength:
*104#
ChecksignalstrengthontheGSMconnection
EnquiryforSignalStrength
CSQ=0–10(WeakSignal)
CSQ=11‐20(AverageSignal)
CSQ=21–30(GoodSignal)
CSQ=Above30(ExcellentSignal)
1.7TimeScheduletosendSMSRemindertotheAdministrator
*109*XXX#
SMScheckmessagetosaytheunitisstillupandrunning.
XXX=Days(Value=000‐255,mustbein3digits,everyweek=007)
Defaultas000(NotSendingSMSreminder)
DefaultTextreadsas“Hi!I'mOK”(Caneditthetextusing*111*Command)
Example:(send)*109*002#thesystemwillstarttocalculatefromthemomentitreceives
theSMS.After2days,itwillsendoutaSMSreminder.
Note:Ifthesystemhadbeenrestarted,itwillclearthetimetoZEROandrecalculateagainfor
2daysfromthemomentthesystemrestarted,thensendouttheSMSreminderafter2days.

GSM-0308WPC User Manual
9|Page
2. SystemAlarmAlertProgramming
2.1CallAlertforTriggerTypeAlarm:
*302*A*B#
B=0or1(0=OFF,1=ON)defaultaswhenalarm,willnotmessagebeforephonecall
alert
A=TriggerTypesasperbelow;
(1):SystemRestart
(2):PowerOutage
(3):PowerRecover
(7):LineCut
(8):LineCutRecover
Note:youcanchooseasmanyofthemyouwantwhichmeansyoucansimplechoose
toon/offthecallfunctionofthe5TypesofAlarmAlert
3. PumpActivation
Commandusetoprogramunitathilltopfromthemainunitinordertoactivatepump
*1000*A#A=0or1(0=OFF,1=ON)
Formoreadditionalcommand,pleasereferto“AdditionalCommandListForGSM‐0308Series”
Table of contents
Popular Controllers manuals by other brands

Zeck Audio
Zeck Audio FOCUS CON2ST Service manual

Micronor
Micronor MR380-1 Series instruction manual

AUTLED
AUTLED LC-006-001 user manual

KOHSEL ELEPHANT
KOHSEL ELEPHANT M40 installation guide

Johnson Controls
Johnson Controls M9106-AGx-2N0x Series installation instructions

NovaStar
NovaStar MBOX600 user manual