1592009000 XW220L GB r1.2 03.08.2015 XW220L 1/4
WING
XW220L
1. GENERAL WARNING
1.1 PLEASE READ BEFORE USING THIS MANUAL
This manual is part of the product and should be kept near the instrument for easy and quick reference.
The instrument shall not be used for purposes different from those described hereunder. It cannot be used
as a safety device.
Check the application limits before proceeding.
Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the
same and unchanged functionality.
1.2 SAFETY PRECAUTIONS
Check the supply voltage is correct before connecting the instrument.
Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden
temperature changes with high atmospheric humidity to prevent formation of condensation
Warning: disconnect all electrical connections before any kind of maintenance.
Fit the probe where it is not accessible by the End User. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” (see
address) with a detailed description of the fault.
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from each
other, without crossing or intertwining.
In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with
inductive loads could be useful.
2. GENERAL DESCRIPTION
Model XW220L, 38x185 mm format, is microprocessor based controller suitable for applications on normal
temperature refrigerating units. It is provided with two relay outputs to control compressor, and the lights
They are also provided with two NTC probe inputs, one for temperature control, one optional, for the display.
There are two digital inputs (free contact) for the door switch and configurable by parameter.
The standard TTL output allows the user to connect, by means of a TTL/RS485 external module, a ModBUS-
RTU compatible monitoring system and to programme the parameter list with the “Hot Key”.
An optional output for remote display “XW-REP” is available.
3. CONTROLLING LOADS
3.1 THE COMPRESSOR
The regulation is performed according to the temperature measured by the thermostat probe with a positive
differential from the set point: if the temperature increases and reaches set point plus differential the compressor
is started and then turned off when the temperature reaches the set point value again.
In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters
“COn” and “COF”.
3.2 FAST FREEZING
When defrost is not in progress, it can be activated the keypad by holding the okey pressed for about 3
seconds. The compressor operates in continuous mode for the time set through the “CCt” parameter. The cycle
can be terminated before the end of the set time using the same activation key, ofor about 3 seconds.
3.3 DEFROST
The defrost interval is control by means of parameter “EdF”: (EdF=in) the defrost is made every “IdF” time,
(EdF=Sd) the interval “IdF” is calculate through Smart Defrost algorithm (only when the compressor is ON).
Defrost is performed through a simple stop of the compressor. Parameter “IdF” controls the interval between
defrost cycles, while its length is controlled by parameter “MdF”.
4. KEYBOARD
To display and modify target set point; in programming mode it selects a parameter or confirm an
operation.
By holding it pressed for 3s when max or min temperature is displayed it will be erased.
To see the max. stored temperature; in programming mode it browses the parameter codes or
increases the displayed value. By holding it pressed for 3s the fast freezing cycle is started.
To see the min stored temperature; in programming mode it browses the parameter codes or
decreases the displayed value.
By holding it pressed for 3s the defrost is started.
Switch ON and OFF the cold room light.
Switch ON and OFF the instrument.
KEY COMBINATIONS
+
To lock and unlock the keyboard.
+
To enter the programming mode.
+
To exit the programming mode.
4.1 USE OF LEDS
Each LED function is described in the following table.
LED
MODE
Function
ON
The compressor is running
FLASHING
- Programming Phase (flashing with LED )
- Anti-short cycle delay enabled
FLASHING
Programming Phase (flashing with LED )
ON
The defrost is enabled
ON
The Fast Freezing cycle is enabled
ON
- ALARM signal
- In “Pr2” indicates that the parameter is also present in “Pr1”
Function of the LEDs placed on the left top side of buttons:
BUTTON
MODE
FUNCTION
SET
FLASHING
The Set point is displayed and it can be modified
SET
FAST FLASHING
The Energy Saving is enabled
DEFROST
ON
The Manual Defrost is activated
LIGHT
ON
The Light is ON
ON/OFF
ON
The instrument is OFF
4.2 HOW TO SEE THE MIN TEMPERATURE
1. Press and release the nkey.
2. The “Lo” message will be displayed followed by the minimum temperature recorded.
3. By pressing the nkey or waiting for 5s the normal display will be restored.
4.3 HOW TO SEE THE MAX TEMPERATURE
1. Press and release the okey.
2. The “Hi” message will be displayed followed by the maximum temperature recorded.
3. By pressing the okey or waiting for 5s the normal display will be restored.
4.4 HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED
To reset the stored temperature, when max or min temperature is displayed :
1. Press SET key until “rST” label starts blinking.
N.B. After the installation RESET the temperature stored .
4.5 HOW TO SEE AND MODIFY THE SET POINT
1. Push and immediately release the SET key: the display will show the Set point value;
2. The SET LED start blinking;
3. To change the Set value push the o or narrows within 10s.
4. To memorise the new set point value push the SET key again or wait 10s.
4.6 TO START A MANUAL DEFROST
1. Push the DEF key for more than 2 seconds and a manual defrost will start.
4.7 TO ENTER IN PARAMETERS LIST “PR1”
To enter the parameter list “Pr1” (user accessible parameters) operate as follows:
1. Enter the Programming mode by pressing the Set and DOWN key for few
seconds ( and start blinking).
2. The instrument will show the first parameter present in “Pr1”
4.8 TO ENTER IN PARAMETERS LIST “PR2”
To access parameters in “Pr2”:
1. Enter the “Pr1” level.
2. Select “Pr2” parameter and press the “SET” key.
3. The “PAS” flashing message is displayed, shortly followed by “0 - -” with a flashing zero.
4. Use o or nto input the security code in the flashing digit; confirm the figure by pressing “SET”. The
security code is “321“.
5. If the security code is correct the access to “Pr2” is enabled by pressing “SET” on the last digit.
Another possibility is the following: after switching ON the instrument the user can push Set and DOWN keys
within 30 seconds.
NOTE: each parameter in “Pr2” can be removed or put into “Pr1” (user level) by pressing “SET” + n. When a
parameter is present in “Pr1” LED is on.
1592009000 XW220L GB r1.2 03.08.2015 XW220L 2/4
4.9 HOW TO CHANGE THE PARAMETER VALUE
1. Enter the Programming mode.
2. Select the required parameter with oor n.
3. Press the “SET” key to display its value ( and LED starts blinking).
4. Use oor nto change its value.
5. Press “SET” to store the new value and move to the following parameter.
To exit: Press SET + UP or wait 15s without pressing a key.
NOTE: the new programming is stored even when the procedure is exited by waiting the time-out.
4.10 HOW TO LOCK THE KEYBOARD
1. Keep the oand nkeys pressed together for more than 3 s the oand nkeys.
2. The “POF” message will be displayed and the keyboard is locked. At this point it is only
possible the viewing of the set point or the MAX o Min temperature stored and to switch
ON and OFF the light, the auxiliary output and the instrument.
TO UNLOCK THE KEYBOARD
Keep the oand nkeys pressed together for more than 3s.
4.11 ON/OFF FUNCTION
By pushing the ON/OFF key, the instrument shows “OFF” for 5 sec. and the ON/OFF LED is
switched ON.
During the OFF status, all the relays are switched OFF and the regulations are stopped; if a
monitoring system is connected, it does not record the instrument data and alarms.
N.B. During the OFF status the Light and AUX buttons are active.
4.12 TO SEE THE PROBE VALUES
1. Enter in “Pr2” level.
2. Select “Prd” parameter with oor n.
3. Press the “SET” key to display “Pb1” label alternate with Pb1 value.
4. Use oand nkeys to display the other probe values.
5. Press “SET” to move to the following parameter.
5. PARAMETER LIST
REGULATION
Hy Differential: (0,1÷25,5°C; 1÷45°F): Intervention differential for set point, always positive. Compressor
Cut IN is Set Point Plus Differential (Hy). Compressor Cut OUT is when the temperature reaches the set
point.
LS Minimum set point limit: (-50,0°C

SET; -58°F÷SET) Sets the minimum acceptable value for the set
point.
US Maximum set point limit: (SET

110°C; SET÷230°F) Set the maximum acceptable value for set point.
OdS Outputs activation delay at start up: (0÷255 min) This function is enabled at the initial start up of the
instrument and inhibits any output activation for the period of time set in the parameter. (Light can work)
AC Anti-short cycle delay: (0÷30 min) interval between the compressor stop and the following restart.
CCt Thermostat override: (0min ÷23h 50min) allows to set the length of the continuous cycle. Can be used,
for instance, when the room is filled with new products.
Con Compressor ON time with faulty probe: (0÷255 min) time during which the compressor is active in case
of faulty thermostat probe. With COn=0 compressor is always OFF.
COF Compressor OFF time with faulty probe: (0÷255 min) time during which the compressor is off in case of
faulty thermostat probe. With COF=0 compressor is always active.
CH Type of action : CL (COOL); Ht (HEAT)
DISPLAY
CF Temperature measurement unit: °C = Celsius; °F = Fahrenheit. When the measurement unit is
changed the SET point and the values of some parameters have to be modified
rES Resolution (for °C): (in = 1°C; de = 0,1°C) allows decimal point display.
de = 0,1°C
in = 1 °C
Lod Local display : select which probe is displayed by the instrument:
P1 = Thermostat probe
P2 = Not used
P3 = auxiliary probe
1r2 = Not used
Red Remote display : select which probe is displayed by the remote display (XW-REP)
P1 = Thermostat probe
P2 = Not used
P3 = auxiliary probe
1r2 = Not used
DEFROST
EdF Defrost mode:
in = interval mode. The defrost starts when the time “Idf” is expired.
Sd = Smartfrost mode. The time IdF (interval between defrosts) is increased only when the compressor
is running (even non consecutively).
IdF Interval between defrosts: (1÷120h) Determines the time interval between the beginning of two defrost
cycles.
MdF (Maximum) duration of defrost: (0÷255 min) it sets the maximum length for defrost.
dFd Display during defrost:
rt = real temperature;
it = temperature reading at the defrost start;
Set = set point;
dEF = “dEF” label;
dEG = “dEG” label;
dAd Defrost display time out: (0

255 min) Sets the maximum time between the end of defrost and the
restarting of the real room temperature display.
dPO First defrost after start-up:
y = Immediately;
n= after the IdF time
dAF Defrost delay after fast freezing: (0min÷23h 50min) after a Fast Freezing cycle, the first defrost will be
delayed for this time.
ALARMS
ALC Temperature alarm configuration
rE = High and Low alarms related to Set Point
Ab = High and low alarms related to the absolute temperature.
ALU High temperature alarm setting:
ALC= rE, 0

50°C or 90°F
ALC= Ab, ALL

110°C or 230°F
when this temperature is reached and after the ALd delay time the HA alarm is enabled.
ALL Low temperature alarm setting:
ALC = rE , 0

50 °C or 90°F
ALC = Ab , - 50°C or -58°F

ALU
when this temperature is reached and after the ALd delay time, the LA alarm is enabled,.
AFH Temperature alarm and fan differential: (0,1÷25,5°C; 1÷45°F) Intervention differential for temperature
alarm set point, always positive.
ALd Temperature alarm delay: (0÷255 min) time interval between the detection of an alarm condition and the
corresponding alarm signalling.
dAO Delay of temperature alarm at start-up: (0min÷23h 50min) time interval between the detection of the
temperature alarm condition after the instrument power on and the alarm signalling.
EdA Alarm delay at the end of defrost: (0

255 min) Time interval between the detection of the temperature
alarm condition at the end of defrost and the alarm signalling.
dot Delay of temperature alarm after closing the door : (0

255 min) Time delay to signal the temperature
alarm condition after closing the door.
doA Open door alarm delay:(0÷255 min) delay between the detection of the open door condition and its
alarm signalling: the flashing message “dA” is displayed.
nPS Pressure switch number: (0

15) Number of activation of the pressure switch, during the “did” interval,
before signalling the alarm event (I2F= PAL).
PROBE INPUTS
Ot Thermostat probe calibration: (-12.0

12.0°C/ -21

21°F) allows to adjust possible offset of the
thermostat probe.
O3 Auxiliary probe calibration: (-12.0

12.0°C/ -21

21°F) allows to adjust possible offsets of the evaporator
probe.
P2P Evaporator probe presence:
n= not present: the defrost stops only by time; y= present: the defrost stops by temperature and time.
P3P Auxiliary probe presence: n= not present; y= present.
HES Temperature increase during the Energy Saving cycle : (-30,0°C

30,0°C / -22÷86°F) sets the
increasing value of the set point during the Energy Saving cycle.
DIGITAL INPUTS
odc Compressor and fan status when open door:
no = normal;
Fan = normal;
CPr = Compressor OFF;
F_C = Compressor OFF.
I1P Door switch input polarity:
CL : the digital input is activated by closing the contact;
OP : the digital input is activated by opening the contact.
I2P Configurable digital input polarity:
CL : the digital input is activated by closing the contact;
OP : the digital input is activated by opening the contact
I2F Digital input operating mode: configure the digital input function:
EAL = generic alarm;
bAL = serious alarm mode;
PAL = Pressure switch;
dFr = Start defrost;
AUS = not used;
Es = Energy Saving;
onF = remote On/OFF.
did Time interval/delay for digital input alarm:(0

255 min.) Time interval to calculate the number of the
pressure switch activation when I2F=PAL. If I2F=EAL or bAL (external alarms), “did” parameter defines
the time delay between the detection and the successive signalling of the alarm.
SAA Set Point for anti-condensing heater: (-50,0÷110,0°C; -58÷230°F) defines the room temperature
setpoint to switch on the anti-condensing heater.
OTHER
Adr RS485 serial address (1÷247): Identifies the instrument address when connected to a ModBUS
compatible monitoring system.
Rel Release software: (read only) Software version of the microprocessor.
Ptb Parameter table: (read only) it shows the original code of the Dixell parameter map.
Prd Probes display: (read only) display the temperature values of the evaporator probe Pb2 and the auxiliary
probe Pb3.
Pr2 Access to the protected parameter list (read only).
6. DIGITAL INPUTS
The Wing series can support up to 2 free contact digital inputs. One is always configured as door switch, the
second is programmable in seven different configurations by the “I2F” parameter.
6.1 DOOR SWITCH INPUT
It signals the door status and the corresponding relay output status through the “odc” parameter:
no = normal;
Fan = normal;
CPr = Compressor OFF;
F_C = Compressor OFF.
Since the door is opened, after the delay time set through parameter “dOA”, the alarm output is enabled and the
display shows the message “dA”. The alarm stops as soon as the external digital input is disabled again. During
this time and then for the delay “dot” after closing the door, the high and low temperature alarms are disabled.
6.2 CONFIGURABLE INPUT - GENERIC ALARM (EAL)
As soon as the digital input is activated the unit will wait for “did” time delay before signalling the “EAL” alarm
message. The outputs status don’t change. The alarm stops just after the digital input is de-activated.
1592009000 XW220L GB r1.2 03.08.2015 XW220L 3/4
6.3 CONFIGURABLE INPUT - SERIOUS ALARM MODE (BAL)
When the digital input is activated, the unit will wait for “did” delay before signalling the “BAL” alarm message.
The relay outputs are switched OFF. The alarm will stop as soon as the digital input is de-activated.
6.4 CONFIGURABLE INPUT - PRESSURE SWITCH (PAL)
If during the interval time set by “did” parameter, the pressure switch has reached the number of activation of
the “nPS” parameter, the “PAL” pressure alarm message will be displayed. The compressor and the regulation
are stopped. When the digital input is ON the compressor is always OFF.
6.5 CONFIGURABLE INPUT - START DEFROST (DFR)
It executes a defrost if there are the right conditions. After the defrost is finished, the normal regulation will
restart only if the digital input is disabled otherwise the instrument will wait until the “Mdf” safety time is expired.
6.6 CONFIGURABLE INPUT - ENERGY SAVING (ES)
The Energy Saving function allows to change the set point value as the result of the SET+ HES (parmeter) sum.
This function is enabled until the digital input is activated.
6.7 CONFIGURABLE INPUT - REMOTE ON/OFF (ONF)
This function allows to switch ON and OFF the instrument.
6.8 DIGITAL INPUTS POLARITY
The digital inputs polarity depends on “I1P” and “I2P” parameters.
CL : the digital input is activated by closing the contact.
OP : the digital input is activated by opening the contact
7. INSTALLATION AND MOUNTING
Instruments XW220L shall be mounted on vertical panel, in a 150x31 mm hole, and fixed using two screws

3
x 2mm. To obtain an IP65 protection grade use the front panel rubber gasket (mod. RG-L). The temperature
range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive gases,
excessive dirt or humidity. The same recommendations apply to probes. Let the air circulate by the cooling
holes.
7.1 CUT OUT
165
150
31
+0.5
-0
+0.5
-0
+1
-1
Ø3 x2
7.2 MOUNTING WITH KEYBOARD COVER OPENING DOWNWARD
CLICK!
1
2
2
3
3
1
1
7.3 MOUNTING WITH KEYBOARD COVER OPENING UPWARD
CLICK!
1
2
2
2
3
3
1
1
8. ELECTRICAL CONNECTIONS
The instruments are provided with screw terminal block to connect cables with a cross section up to 2,5 mm2 for
the digital and analogue inputs. Relays and power supply have a Faston connection (6,3mm). Heat-resistant
cables have to be used. Before connecting cables make sure the power supply complies with the instrument’s
requirements. Separate the probe cables from the power supply cables, from the outputs and the power
connections. Do not exceed the maximum current allowed on each relay, in case of heavier loads use a suitable
external relay.
N.B. Maximum current allowed for all the loads is 20A.
8.1 PROBE CONNECTIONS
The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration. It is
recommended to place the thermostat probe away from air streams to correctly measure the average room
temperature.
9. TTL SERIAL LINE
The TTL connector allows, by means of the external module TTL/RS485, to connect the unit to a network line
ModBUS-RTU compatible as the Dixell monitoring system XJ500 (Version 3.0).
The same TTL connector is used to upload and download the parameter list of the “HOT KEY“.
10. USE OF THE PROGRAMMING “HOT KEY “
The Wing units can UPLOAD or DOWNLOAD the parameter list from its own E2 internal memory to the “Hot
Key” and vice-versa.
10.1 DOWNLOAD (FROM THE “HOT KEY” TO THE INSTRUMENT)
1. Turn OFF the instrument by means of the ON/OFF key, remove the TTL serial cable if present, insert
the “Hot Key” and then turn the Wing ON.
2. Automatically the parameter list of the “Hot Key” is downloaded into the Wing memory, the “DoL”
message is blinking. After 10 seconds the instrument will restart working with the new parameters.
3. Turn OFF the instrument remove the “Hot Key”, plug in the TTL serial cable, then turn it ON again.
At the end of the data transfer phase the instrument displays the following messages:
“end “ for right programming. The instrument starts regularly with the new programming.
“err” for failed programming. In this case turn the unit off and then on if you want to restart the download again
or remove the “Hot key” to abort the operation.
10.2 UPLOAD (FROM THE INSTRUMENT TO THE “HOT KEY”)
1. Turn OFF the instrument by means of the ON/OFF key and remove the TTL serial cable if present; then
turn it ON again.
2. When the Wing unit is ON, insert the “Hot key” and push okey; the "uPL" message appears.
3. Push “SET” key to start the UPLOAD; the “uPL” message is blinking.
4. Turn OFF the instrument remove the “Hot Key”, plug in the TTL serial cable, then turn it ON again.
At the end of the data transfer phase the instrument displays the following messages:
“end “ for right programming.
“err” for failed programming. In this case push “SET” key if you want to restart the programming again or
remove the not programmed “Hot key”.
11. ALARM SIGNALS
Message
Cause
Outputs
“P1”
Thermostat probe failure
Alarm output ON; Compressor output according to
parameters “COn” and “COF”
“P3”
Auxiliary probe failure
Alarm output ON; Other outputs unchanged
“HA”
Maximum temperature alarm
Alarm output ON; Other outputs unchanged
“LA”
Minimum temperature alarm
Alarm output ON; Other outputs unchanged
“EE”
Data or memory failure
Alarm output ON; Other outputs unchanged
“dA”
Defrost timeout alarm
Alarm output ON; Other outputs unchanged
“dAL”
Door switch alarm
Alarm output ON; Other outputs unchanged
“EAL”
External alarm
Alarm output ON; Other outputs unchanged
“BAL”
Serious external alarm
Alarm output ON; Other outputs OFF
“PAL”
Pressure switch alarm
Alarm output ON; Other outputs OFF
The alarm message is displayed until the alarm condition is recovery.
All the alarm messages are showed alternating with the room temperature except for the “P1” which is flashing.
To reset the “EE” alarm and restart the normal functioning press any key, the “rSt” message is displayed for
about 3s.
11.1 SILENCING BUZZER
Once the alarm signal is detected the buzzer and the relay are is silenced by pressing any key.
11.2 “EE” ALARM
The Dixell instruments are provided with an internal check for the data integrity. Alarm “EE” flashes when a
failure in the memory data occurs. In such cases the alarm output is enabled.
11.3 ALARM RECOVERY
Probe alarms : “P1” (probe1 faulty), and “P3”; they automatically stop 10s after the probe restarts normal
operation. Check connections before replacing the probe.
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns to normal
values or when the defrost starts.
Door switch alarm “dA” stop as soon as the door is closed.
External alarms “EAL”, “BAL” stop as soon as the external digital input is disabled “PAL” alarm is recovered by
switching OFF the instrument.
1592009000 XW220L GB r1.2 03.08.2015 XW220L 4/4
12. TECHNICAL DATA
Housing: self extinguishing ABS.
Case: facia 38x185 mm; depth 76mm
Mounting: panel mounting in a 150x31 mm panel cut-out with two screws.

3 x 2mm.
Distance between the holes 165mm
Protection: IP20.
Frontal protection: IP65 with frontal gasket mod RG-L. (optional)
Connections: Screw terminal block

2,5 mm2heat-resistant wiring and 6,3mm Faston
Power supply: 230Vac or. 110Vac

10%
Power absorption: 7VA max.
Display: 3 digits, red LED, 14,2 mm high.
Inputs: 2 NTC probes
Digital inputs: 2 free voltage
Relay outputs: Total current on loads MAX. 20A
compressor: relay SPST 20(8) A, 250Vac
light: relay SPST 16(3) A, 250Vac
Other output: alarm buzzer
Serial output: TTL standard
Communication protocol: Modbus - RTU
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.
Pollution grade: normal
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20

85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
13. CONNECTIONS
13.1 XW220L
1917 18 2321 22
Common
Door switch
Digital inp.
Display
Room
XW220L
CompLight
Line
Neutral
910 11 12 13 14
20A
250Vac MAX
20A
16A
250Vac
14. DEFAULT SETTING VALUES
Label
Name
Range
Default
Level
REGULATION
°C/°F
XW220L
Set
Set point
LS÷US
3
Pr1
Hy
Differential
0,1÷25,5 °C / 1÷45°F
2
Pr1
LS
Minimum set point
-50,0°C÷SET / -58°F÷SET
-10
Pr2
US
Maximum set point
SET ÷ 110°C / SET ÷ 230°F
20
Pr2
OdS
Outputs activation delay at start up
0÷255 min.
1
Pr2
AC
Anti-short cycle delay
0÷30 min.
1
Pr1
CCt
Compressor ON time during fast freezing
0 ÷ 23h 50 min.
0
Pr2
COn
Compressor ON time with faulty probe
0÷255 min.
15
Pr2
COF
Compressor OFF time with faulty probe
0÷255 min.
30
Pr2
CH
Type of action
CL÷Ht
CL
Pr2
DISPLAY
CF
Temperature measurement unit
°C ÷ °F
°C
Pr2
rES
Resolution (integer/decimal point)
in ÷ de
de
Pr1
Lod
Local display
P1 ÷ 1r2
P1
Pr2
Red
Remote display
P1 ÷ 1r2
P1
Pr2
DEFROST
EdF
Defrost mode
In, Sd
In
Pr2
IdF
Interval between defrost cycles
1÷120h
8
Pr1
MdF
(Maximum) length for 1° defrost
0÷255 min.
20
Pr1
dFd
Displaying during defrost
rt, it, SEt, dEF, dEG
it
Pr2
dAd
MAX display delay after defrost
0÷255 min.
30
Pr2
dPO
First defrost after start up
n ÷ y
n
Pr2
dAF
Defrost delay after fast freezing
0 ÷ 23h 50 min.
2
Pr2
ALARMS
ALC
Temperature alarms configuration
rE÷Ab
rE
Pr2
ALU
MAXIMUM temperature alarm
-50,0÷110°C/ -58÷230°F
10
Pr1
ALL
minimum temperature alarm
-50,0÷110°C/ -58÷230°F
10
Pr1
AFH
Temperature alarm differential
0,1÷25,5 °C / 1÷45°F
2
Pr2
ALd
Temperature alarm delay
0÷255 min.
15
Pr2
dAO
Delay of temperature alarm at start up
0 ÷ 23h 50 min.
1.3
Pr2
EdA
Alarm delay at the end of defrost
0÷255 min.
30
Pr2
dot
Delay of temperature alarm after closing the door
0÷255 min.
15
Pr2
dOA
Open door alarm delay
0÷255 min.
15
Pr2
nPS
Pressure switch activation number
0÷15
0
Pr2
ANALOGUE INPUTS
Ot
Thermostat probe calibration
-12,0÷12,0°C / -21÷21°F
0
Pr1
O3
Auxiliary probe calibration
-12,0÷12,0°C / -21÷21°F
0
Pr2
P3P
Auxiliary probe presence
n ÷ y
n
Pr2
HES
Temperature increase during the Energy Saving
cycle
-30÷30°C / -22÷86°F
0
Pr2
DIGITAL INPUTS
Odc
Open door control
no, Fan, CPr, F_C
Fan
Pr2
I1P
Door switch polarity
CL÷OP
CL
Pr2
I2P
Configurable digital input polarity
CL÷OP
CL
Pr2
i2F
Digital input configuration
EAL, bAL, PAL, dFr,
AUS, ES, OnF
EAL
Pr2
dId
Digital input alarm delay
0÷255 min.
5
Pr2
OTHER
Adr
Serial address
0÷247
1
Pr1
rEL
Software release
- - -
1.0
Pr2
Ptb
Map code
- - -
- - -
Pr2
Prd
Probes display
Pb1÷Pb3
- - -
Pr2
Pr2
Access parameter list
- - -
- - -
Pr2

Other Emerson Controllers manuals

Emerson Fisher 67C Series User manual

Emerson

Emerson Fisher 67C Series User manual

Emerson EZH User manual

Emerson

Emerson EZH User manual

Emerson Vilter MicroVission Operation manual

Emerson

Emerson Vilter MicroVission Operation manual

Emerson EIM HQ Series User manual

Emerson

Emerson EIM HQ Series User manual

Emerson Copeland XC643 User guide

Emerson

Emerson Copeland XC643 User guide

Emerson Fisher 1305 Series User manual

Emerson

Emerson Fisher 1305 Series User manual

Emerson Y696 User manual

Emerson

Emerson Y696 User manual

Emerson Bettis SCE300 User manual

Emerson

Emerson Bettis SCE300 User manual

Emerson FISHER LR128 Series User manual

Emerson

Emerson FISHER LR128 Series User manual

Emerson FIELDVUE DVC6200f User manual

Emerson

Emerson FIELDVUE DVC6200f User manual

Emerson Bettis RGS Q Series User manual

Emerson

Emerson Bettis RGS Q Series User manual

Emerson Fisher easy-Drive 200R User manual

Emerson

Emerson Fisher easy-Drive 200R User manual

Emerson Fisher 1051 User manual

Emerson

Emerson Fisher 1051 User manual

Emerson Dixell XM660K Wiring diagram

Emerson

Emerson Dixell XM660K Wiring diagram

Emerson NELSON HEAT TRACE CM-2201 User manual

Emerson

Emerson NELSON HEAT TRACE CM-2201 User manual

Emerson ControlWave User manual

Emerson

Emerson ControlWave User manual

Emerson E2 RX Series Manual

Emerson

Emerson E2 RX Series Manual

Emerson Bettis RTS User manual

Emerson

Emerson Bettis RTS User manual

Emerson Bettis XTE3000 User manual

Emerson

Emerson Bettis XTE3000 User manual

Emerson Fisher 1051 User manual

Emerson

Emerson Fisher 1051 User manual

Emerson DIXELL XR60T User manual

Emerson

Emerson DIXELL XR60T User manual

Emerson Bettis RP4AF User manual

Emerson

Emerson Bettis RP4AF User manual

Emerson FISHER 912N Series User manual

Emerson

Emerson FISHER 912N Series User manual

Emerson dixell XT111D Wiring diagram

Emerson

Emerson dixell XT111D Wiring diagram

Popular Controllers manuals by other brands

Vestax FADERBOARD owner's manual

Vestax

Vestax FADERBOARD owner's manual

ELPRO ULTIMA LLC-2 operating manual

ELPRO

ELPRO ULTIMA LLC-2 operating manual

Felix Instruments AccuStore F-901 manual

Felix Instruments

Felix Instruments AccuStore F-901 manual

Cedrat Technologies CCBu40 Product and Warranty Information

Cedrat Technologies

Cedrat Technologies CCBu40 Product and Warranty Information

Schrack Technik EM-250 User instruction

Schrack Technik

Schrack Technik EM-250 User instruction

Hanna Instruments HI 9931 instruction manual

Hanna Instruments

Hanna Instruments HI 9931 instruction manual

Analog Devices ADT7473 manual

Analog Devices

Analog Devices ADT7473 manual

INVT SV-DA200 Series Operation manual

INVT

INVT SV-DA200 Series Operation manual

Actuonix LAC User configuration guide

Actuonix

Actuonix LAC User configuration guide

Regin HR1-DH instructions

Regin

Regin HR1-DH instructions

KAEL ke-DP01 instruction manual

KAEL

KAEL ke-DP01 instruction manual

Avonic CM-CON100 user manual

Avonic

Avonic CM-CON100 user manual

CBM LUMIX user manual

CBM

CBM LUMIX user manual

Mitsubishi Electric MELSEC-A0J2H Series Handbook

Mitsubishi Electric

Mitsubishi Electric MELSEC-A0J2H Series Handbook

e-survey P8II quick start guide

e-survey

e-survey P8II quick start guide

Axio AX-RAF-15D installation manual

Axio

Axio AX-RAF-15D installation manual

Extron electronics HD CTL 100 Setup guide

Extron electronics

Extron electronics HD CTL 100 Setup guide

WAMGROUP TOPERX ANSY 9300 maintenance

WAMGROUP

WAMGROUP TOPERX ANSY 9300 maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.