For PneuClean filter element PC5001
The following inspection procedure must be implemented in order for
the product warranty to be in effect. Any change or deviation from
this procedure voids the Dixon Bayco product warranty and removes
Dixon Bayco from any contamination liability.
1. Remove quick disconnect V-clamp and remove end cap.
2. Open slowly and listen for pressure.
3. Pull the element completely out of the assembly housing
4. Carefully look into the housing at the bottom gasket and guide the
plate.
5. Check to see if the white bottom gasket is in place and clean.
Replace if missing, broken or damaged. Clean the housing if dirty.
6. Check the inside of the sidewall of the housing for oil residue and
small particles. Removed with clean cloth, steam, or cleaning device
of choice.
7. Carefully inspect the outer surface of the filter element by looking
into the pleated area for very dark colored media, oil or grease
residue, fiberglass fibers and caked on product. If this surface
appears to have heavy deposits of contaminates such as metal, iron
oxide or caked on product, and/or the element has been in service for
twelve months it should be replaced.
8. Turn element up on its end where you can look down into the open
end. Use a light or flashlight, if needed. Carefully look at the sides of
the element.
• If the screen wire and/or media show signs of deterioration
replace immediately.
• If the screen wire and/or media do not show signs of
deterioration, but has been in operation for twelve months,
replace immediately.
• If product is caked up inside this area, replace immediately.
• If the element has been run longer than twelve months,
replace immediately.