Description
The DMX-Universal-Demux is equipped for universal applications with several
operation modes. 8 outputs release a signal depending on the DMX-input signal and
according to the operation mode.
DMX
INTERFACE
RISC
CONTROLLER
DRIVER
DMX
DRIVER
DRIVER
DRIVER
DRIVER
DRIVER
MODE
SETTINGS DRIVER
DRIVER
8 outputs with open-collector driver
There are 8 outputs with open collector output driver for controlling external devices.
Voltages from 12V up to 24V
The DMX-Universal-Demux operates with supply voltages from 12V up to 24V.
Different operation modes
By jumper the operating mode of the DMX-Universal-Demux can be selected.
Available are the operation modes Threshold / Binär / PWM / Servo / Strobo.
Controllable via DMX
The DMX-Universal-Demux is controlled by DMX and uses 1 or 8 DMX channels
depending on the operating mode.
LED status display
The LED status display shows the DMX reception.
DIN rail housing available
The DIN rail housing 700 is available as accessory for the DMX-Universal-Demux.

DMX-Universal-Demux 3
Data sheet
Supply voltage: 7-24V DC
Current consumption: 40mA@12V / 35mA@24V
(without load)
DMX-Input: 1 or 8 DMX-Channels
(depends on selected mode)
Output: 8 open-collector outputs
max. 500mA
Operation mode: Threshold (switches at 50%)
Binary (8-Bit)
PWM (~175Hz)
Servo
Strobo
Connectors: Screw terminals
Dimensions: 64,2mm x 82mm

DMX-Universal-Demux 4
Connection

DMX-Universal-Demux 5
Addressing
The starting address is adjustable via a DIP-Switch. Switch 1 has the valency 2
0
(=1),
switch 2 has the valency 2
1
(=2) and so on… finally switch 9 has the valency 2
8
(=256). The sum of the switches showing ON, represents the starting address.
Address
Switch Address
Switch
1
... ...
2
508
3
509
4
510
5
511
LED-Display
The LED is a multifunctional display. In the normal operation mode the LED lights
non-stop. In this case the device is working. If the LED is permanently dark, there is
no DMX512-input-signal.
Furthermore the LED signals the operation status. In this case, the LED light up in
short pitches and then turns into off modus. The number of flashing signals is equal
to the number of the error status:
Error
Status
Error
Description
1 No DMX No DMX-signal existing
2 Address error Please check the adjusted DMX-Address
3 DMX-Signal error An invalid DMX input signal is determined,
invert the signal line by changing switch 2
and 3 or use a twisted pair wire.
1
2
4
8
16
32
641
28
256

DMX-Universal-Demux 6
Operation mode
The operation mode is selectable via a jumper. It is important to place the jumper in
accordance to the following drawings to ensure a clean function.
It is not possible to combine the modes.
Treshold value-output (no jumper placed)
In the mode “Treshold value” there will be received 8
successive DMX-Channels. The belonging output
will be set on OFF if the received value is between 0
and 127 and set on ON if the received value is
between 128 and 255. Thereby output 1 is according
to the first and output 8 is according to the last channel.
This mode allows switching external load relays.
The following picture shows the connection:
V+
GND
GND
GND
OUT1
GND
DMX-
DMX
+
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
To invert the output-signal please use switch 10.
J1
J2
J3
J4
J5

DMX-Universal-Demux 7
Binary-Output (only jumper J1 is placed)
In the „binary-mode“ only one DMX-Channel
needed. The received value will be binary outputted
at the output. Thereby output 1 is according to the
first and output 8 is according to the last bit.
Example: DMX-Value: 77
D
= 01001101
B
DMX-Value: 219
D
= 11011011
B
Output1: ON 01001101
B
Output 1: ON 11011011
B
Output 2: OFF 01001101
B
Output 2: ON 11011011
B
Output 3: ON 01001101
B
Output 3: OFF 11011011
B
Output 4: ON 01001101
B
Output 4: ON 11011011
B
Output 5: OFF 01001101
B
Output 5: ON 11011011
B
Output 6: OFF 01001101
B
Output 6: OFF 11011011
B
Output 7: ON 01001101
B
Output 7: ON 11011011
B
Output 8: OFF 01001101
B
Output 8: ON 11011011
B
To invert the output-signal please use switch 10.
Strobe-Control (only jumper J2 is placed)
The DMX-Universal-Demux outputted 8 controlling
signals for stroboscope in the strobe-control-mode.
Thereby each output will be triggered with one DMX-
Channel.
The DMX-Value assignment is as follows:
DMX
Channel DMX
Value Function
1...8
0-10 Stroboscope off
11-249 Flashing speed slow →fast
250-255
Synchron flash
Only one time the output will be triggered. Switch
back and forth between the DMX-Value 0 and
255 to get a synchronized flashing.
J1
J2
J3
J4
J5
J1
J2
J3
J4
J5

DMX-Universal-Demux 8
PWM-Output (only jumper J3 is placed)
In the PWM-Mode 8 successive DMX-Channels are
outputted as PWM-Signal. Depending on the DMX-
Value the PWM-signal will be generated in a range
of 0-100%.
T
ON
T
OFF
DMX LEVEL: 64
T
ON
T
OFF
DMX LEVEL: 192
The PWM-Frequency is ca. 175 Hz.
To invert the output-signal please use switch 10.
Servo-Control (only jumper J4 is placed)
The DMX-Universal-Demux receives 8 successive
DMX-Channels and outputted a signal for triggering
customary Servos. Thereby each output will be used
to trigger one Servo.
For operating with Servos is a 5V power supply necessary, in the rule.
Please note, for the most Servos an additional resistor is needed which must
be connected between the data line and +5V.
J1
J2
J3
J4
J5
J1
J2
J3
J4
J5

DMX-Universal-Demux 9
Equipment
Top-hat rail housing 700
Power supply 12V / 20W

DMX-Universal-Demux 10
CE-Conformity
This assembly (board) is controlled by a microprocessor and uses
high frequency. In order to maintain the properties of the module with
regard to CE conformity, installation into a closed metal housing in
accordance with the EMC directive 2014/30/EU is necessary.
Risk-Notes
You purchased a technical product. Conformable to the best available technology the
following risks should not excluded:
Failure risk: The device can drop out partially or completely at any time without
warning. To reduce the probability of a failure a redundant system structure is
necessary.
Initiation risk: For the installation of the board, the board must be connected and
adjusted to foreign components according to the device paperwork. This work can
only be done by qualified personnel, which read the full device paperwork and
understand it.
Operating risk: The Change or the operation under special conditions of the
installed systems/components could as well as hidden defects cause to breakdown
within the running time.
Misusage risk: Any nonstandard use could cause incalculable risks and is not
allowed.
Warning: It is not allowed to use the device in an operation, where the safety of
persons depend on this device.
Disposal
Electronical and electronic products must not be disposed in
domestic waste. Dispose the product at the end of its service life
in accordance with applicable legal regulations.
Information on this can be obtained from your local waste
disposal company.

DMX4ALL GmbH
Reiterweg 2A
D-44869 Bochum
Germany
Last changes: 12.02.2019
© Copyright DMX4ALL GmbH
All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another
procedure) without written permission or processed, multiplied or spread using electronic systems.
All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be
excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the
legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not
contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous
announcement.
Other manuals for DMX-Universal-Demux
1
This manual suits for next models
1
Table of contents
Other DMX4ALL Control Unit manuals
Popular Control Unit manuals by other brands

Caleffi solar
Caleffi solar 258 Series manual

A.R.I.
A.R.I. D-025 L ARISENSE Installation operation & maintenance

Microhard Systems
Microhard Systems Nano Series operating manual

Conductrix Wampfler
Conductrix Wampfler 0832 installation instructions

RF-Star
RF-Star RF-BM-ND04 manual

CLA-VAL
CLA-VAL 50B-4KG1 Installation, operation and maintanance manual