6. ELECTRICAL WIRINGELECTRICAL WIRING
ELECTRICAL WIRINGELECTRICAL WIRING
ELECTRICAL WIRING
See FIG. 6.
NOTE:NOTE:
NOTE:NOTE:
NOTE: All wiring must comply with the NationalAll wiring must comply with the National
All wiring must comply with the NationalAll wiring must comply with the National
All wiring must comply with the National
Electrical Code or CSA Standard C22.1, CanadianElectrical Code or CSA Standard C22.1, Canadian
Electrical Code or CSA Standard C22.1, CanadianElectrical Code or CSA Standard C22.1, Canadian
Electrical Code or CSA Standard C22.1, Canadian
Electric Code, Part 1; and all local codes.Electric Code, Part 1; and all local codes.
Electric Code, Part 1; and all local codes.Electric Code, Part 1; and all local codes.
Electric Code, Part 1; and all local codes.
A.A.
A.A.
A. GENERALGENERAL
GENERALGENERAL
GENERAL
1. All wiring must be at least 12 AWG.
2. Two independent 15 amp circuits must be supplied to
the air conditioner.
3. Two conductors plus a ground must be provided for
each circuit protected by a 15 amp slow-blow fuse or a
15 amp HACR type circuit breaker.
B.B.
B.B.
B. UNIT LINE VOLTAGE (See Fig. 6)UNIT LINE VOLTAGE (See Fig. 6)
UNIT LINE VOLTAGE (See Fig. 6)UNIT LINE VOLTAGE (See Fig. 6)
UNIT LINE VOLTAGE (See Fig. 6)
1. The 39424 Electrical Control Box, and Comfort control
Center was shipped in a separate package.
2. Locate the unit electrical box. Remove the cover from
the electrical box.
A. Using thefour (4)mounting screws supplied,mount
the electrical box high on a wall within the air
conditioner storage compartment.
B. Each electrical circuit terminal block is marked.
CIR. 1 L1 N GR
CIR. 2 L1 N GR
C. Route two independent 15 amp supply circuits to
theairconditionerelectricalbox.Eachsupplyshould
be marked Cir #1 and Cir #2.
D. Circuit #1 should be wired directly from the coach's
main breaker panel.
E. Circuit #2 should be wired through the on-board
generator.
NOTE:Astandard30amphookupwillnotpowerNOTE:Astandard30amphookupwillnotpower
NOTE:Astandard30amphookupwillnotpowerNOTE:Astandard30amphookupwillnotpower
NOTE:Astandard30amphookupwillnotpower
bothCircuit1andCircuit2andthecoach'sotherbothCircuit1andCircuit2andthecoach'sother
bothCircuit1andCircuit2andthecoach'sotherbothCircuit1andCircuit2andthecoach'sother
bothCircuit1andCircuit2andthecoach'sother
major appliances.major appliances.
major appliances.major appliances.
major appliances.
3. Route field supply Cir. #1 to terminal block Cir. #1.
Attach black "HotHot
HotHot
Hot" to "L1L1
L1L1
L1" terminal. Attach White to "NN
NN
N"
terminal and attach the ground wire to the "GRGR
GRGR
GR" termi-
nal. Route field supply Cir. #2 to terminal block Cir. #2.
AttachBlack"HotHot
HotHot
Hot"to "L1L1
L1L1
L1" terminal. Attach Whiteto "NN
NN
N"
terminal and attach the ground wire to the "GR" termi-
nal.
5. Route the nonmetallic liquid-tight tubing with the two 9-
pin connectors and ground wire to the air conditioning
unit.
6. Remove the field connect junction box cover. Remove
lower vent panel. Place pin connectors Cir. #1 and Cir.
#2 and ground wire through bushing in vent panel.
Movebushingdowntubingaboutfour(4)inches.Install
bushing with tubing in vent panel. Place the tubing into
slot at bottom of the junction box with about 3/4 inches
extending into junction box. Install vent panel using
screws removed.
7. Locateground wireandlocategroundscrewinjunction
box. Attach ground wire to junction box using ground
screw.
8. Locate pin connector for Cir. #2. Insert connector into
receptacle marked Cir. #2. Push the connector into
seat. Pull lightly on connector assuring it is attached.
9. Repeat Step 8 using Cir. #1 connector.
FAILURE TO CORRECTLY WIRE THE UNIT WILLFAILURE TO CORRECTLY WIRE THE UNIT WILL
FAILURE TO CORRECTLY WIRE THE UNIT WILLFAILURE TO CORRECTLY WIRE THE UNIT WILL
FAILURE TO CORRECTLY WIRE THE UNIT WILL
CAUSE PRODUCT DAMAGE AND MAY CAUSE PER-CAUSE PRODUCT DAMAGE AND MAY CAUSE PER-
CAUSE PRODUCT DAMAGE AND MAY CAUSE PER-CAUSE PRODUCT DAMAGE AND MAY CAUSE PER-
CAUSE PRODUCT DAMAGE AND MAY CAUSE PER-
SONAL INJURY.SONAL INJURY.
SONAL INJURY.SONAL INJURY.
SONAL INJURY.
7.7.
7.7.
7. DOMETIC COMFORT CONTROLDOMETIC COMFORT CONTROL
DOMETIC COMFORT CONTROLDOMETIC COMFORT CONTROL
DOMETIC COMFORT CONTROL
CENTER™ & CABLE INSTCENTER™ & CABLE INST
CENTER™ & CABLE INSTCENTER™ & CABLE INST
CENTER™ & CABLE INSTALLAALLA
ALLAALLA
ALLATIONTION
TIONTION
TION
A.A.
A.A.
A. LOCATIONLOCATION
LOCATIONLOCATION
LOCATION
1) If the system is to be used WITHOUTWITHOUT
WITHOUTWITHOUT
WITHOUT a RemoteRemote
RemoteRemote
Remote
Temperature SensorTemperature Sensor
Temperature SensorTemperature Sensor
Temperature Sensor, the proper location of the
Comfort Control CenterComfort Control Center
Comfort Control CenterComfort Control Center
Comfort Control Center™ is very important to
ensure that it will provide a comfortable RV tem-
perature. Observe the following rules when se-
lecting a location:
a) Locate the Comfort Control CenterComfort Control Center
Comfort Control CenterComfort Control Center
Comfort Control Center™ 54"
above the floor.
b) Install the Comfort Control Center™Comfort Control Center™
Comfort Control Center™Comfort Control Center™
Comfort Control Center™ on a
partition, not on an outside wall.
c) NEVERNEVER
NEVERNEVER
NEVER expose it to direct heat from lamps,
sun or other heat producing items.
d) Avoid locations close to doors that lead out-
side, windows or adjoining outside walls.
e) Avoid locations close to supply registers and
the air from them.
2) If the system is to be used WITHWITH
WITHWITH
WITH a RemoteRemote
RemoteRemote
Remote
Temperature SensorTemperature Sensor
Temperature SensorTemperature Sensor
Temperature Sensor in ALLALL
ALLALL
ALL zones, the comfort
control Center may be mounted anywhere that is
convenientinthecoach.Trytoavoidhardtoreach
and hard to see areas.
3) A 3/8" diameter hole will be needed to route the
cable through the wall.
B.B.
B.B.
B. CONTROL CABLE INSTALLATIONCONTROL CABLE INSTALLATION
CONTROL CABLE INSTALLATIONCONTROL CABLE INSTALLATION
CONTROL CABLE INSTALLATION
A 4-conductor telephone cable must be routed from the
electronic control box to the Comfort Control CenterComfort Control Center
Comfort Control CenterComfort Control Center
Comfort Control Center™.
1) Choose the shortest, most direct route to the
Comfort Control CenterComfort Control Center
Comfort Control CenterComfort Control Center
Comfort Control Center™ location selected.
Leave 6" of cable extending through the wall.
2) The cable that should be used is a flat, 4-conduc-
tor telephone cable.
3) The cable must be terminated with a telephone
RJ-11connector.Refertothecrimptool manufac-
turer for crimping instructions. Ensure that the
cable is installed into the connector correctly be-
fore crimping. (See FIG. 4).
FIG. 4FIG. 4
FIG. 4FIG. 4
FIG. 4